Installation and maintenance
Mounting the bracket
On the bottom of the movinghead, there are two holes to mount the included bracket, using the included
bolts. It is possible to mount a G-clamp or halfcoupler to this bracket. It is also possible to mount the bracket
on a ceiling, wall, bar, floor, desk or any flat surface. Use proper equipment to install this fixture, as a
dropping fixture may cause severe injury! Ayra is not responsible for any damage or injuries caused by
improper installation.
Cleaning
Make sure to clean the exterior of the unit frequently, as the build-up of dust and dirt may have negative
effects on the cooling and optics of the fixture.
The exterior (plastic parts) of the unit can be cleaned with a damp cloth. The optics of the fixture can be
cleaned with a clean cloth or paper towel, with the addition of a non-aggressive glass cleaning solution.
Clean the fan outlet and the cooling vents with a small brush, while using vacuum cleaner suction to remove
any loose dust and/or dirt.
Clean the exterior of this fixture once a month. When using this fixture intensively, the frequency of
maintenance needs to be increased.
Transport
When using this fixture in mobile setups, provide sufficient protection during transport. Use the original
packaging of this unit, or use a professional flightcase with proper foam inlay. This way the electronics, optics
and housing are protected against severe shocks, exterior damage and failing electronics.
Make sure the moving parts of the movinghead (pan and tilt motors) are secured during transport. Shocks
and fierce movement of the pan and tilt stepping motors may cause permanent damage.
After use, let the unit cool down for at least 10 minutes. When using DMX, use the ‘black out’ option on your
DMX controller. This way the unit is positioned in a static stand-by mode and the internal fan is able to cool
down the internal electronics, which decreases the chance of damage during transport.
Replacing the internal fuse
First check whether a failing power supply may be the cause of malfunction. When you suspect that the
internal fuse is broken, the fuse can be replaced by removing the fuse cover, located directly below the
power inlet.
WARNING: Before changing the fuse, always disconnect the fixture from your wall outlet or any other power
supply to prevent electric shocks.
Always replace a broken fuse with a fuse that has the same type and rating. After the fuse has been
replaced, always close the fuse-cover. Reconnect the fixture to your power supply and check whether the
problem is solved. When this does not solve your problem, contact your local dealer for help.
Spare parts
This unit has no user serviceable parts inside. When any damage to internal components occurs, contact
your local dealer or a specialized technician in order to repair the fixture.
Checkup
To prevent dangerous situations, make sure your fixture is in optimal condition before using it. Check your
fixture frequently by using the following checklist:
- All screws must be mounted tightly.
- Check all screws and metal parts for corrosion. No visible corrosion may be present.
- The exterior of your fixture must be in optimal condition. Check your fixture for dents, cracks or missing
parts.
- Your installation spot must be in optimal condition. Check your installation spot for corrosion, cracks, dents
and strength.
Any information and illustrations shown in this user manual are subject to change without further notice.
User manual version: 3.0
Creation date + author initials: 27-12-2013 RV Revision date + author initials: 18-02-2014 RV