Operation and Mounting
To activate the device, plug it into a mains socket. Once it's connected to an active power source, it will turn
on automatically.
The device cannot be operated while it is still starting up and displays the ‘AYRA’ logo. Once the device has
fully started up, it will automatically jump to the last mode and setting. Operation modes and other settings
shown on the display can now be adjusted or changed via the menu buttons.
If a DMX signal is detected, the device shall automatically switch to DMX mode and the DMX address that
was last used. For a new device, this is usually DMX address 001. The DMX address can of course be
changed via the display and menu buttons.
The functions, modes and settings can be changed by using the display and menu buttons. Push ‘Enter’ to
select a function or to confirm a change. Push ‘Up’ and ‘Down’ to change any values and push the ‘Menu’
button to return to the main menu. A few seconds after confirming a setting by pressing ‘Enter’, the device
shall automatically return to the main menu and perform the set actions. This can be sped up by holding the
‘Menu’ button down for 2 seconds after confirming a setting by pressing ‘Enter’. This is usually done after
adjusting the working mode or DMX address.
The Menu includes the following options and fuctions:
Display
Mode
Function
ADDR / A001
DMX Address Configuration
Address A001 … A512
CHAN
Channel Mode Selection
3CH / 5CH / 7CH
NASL
Slave Mode
Master
Slave
COLO
Colour Presets
CO 1 – 15 (Colour Presets)
Stro 0-100 (Stroboscope Off up to 100%)
JUMP
Colour Jump Programme
JU 1-100 Jump Speed, slow to fast
Stro 0-100 (Stroboscope Off up to 100%)
FADE
Colour Fade Programme
FA 1-100 Fade Speed, slow to fast
Stro 0-100 (Stroboscope Off up to 100%)
MANU
Manual Mode
Stro 0-100 (Stroboscope Off up to 100%)
Dim 0-100 (Dimmer Level 0 to 100%)
Red 0-100 (Intensity Red 0 to 100%)
Gree 0-100 (Intensity Green 0 to 100%)
Blue 0-100 (Intensity Blue 0 to 100%)
SOUND
Sound-Controlled Mode
Modus: ON / OFF
SENS
Sound Sensitivity
0 - 100: Sensitivity in %
BLND
DMX Signal Loss Mode Selection
No: Normal mode, switch to automatic
programme
Yes: Blackout during DMX signal loss
LED
LED Display Off / On when not in
use
ON/OFF
DISP
Display Inversion
Display invert, disp - dslp
TEST
Test Mode
Test programme to check the operation of each
LED by illuminating each LED one by one
TEMP
Temperature Display
Displayed in Degrees Celsius
FHRS
Duration of use
0000 – 9999 Hours of use
VER
Firmware Version
Displays current version of firmware installed.
This cannot be adjusted or changed
The information in this user manual is subject to change at any time without notice.
Version: 1.0
Date of creation and author's initials: 07-10-2019 RV
Revision date and author's initials: -