Remove the thermostatic mixer handle.  Carefully remove 

the retaining clip and the stop ring from the stem.  
Turn the water on to the handshower.  Place a thermom-

eter in the water stream.  Turn the thermostatic mixer stem 

until the water coming out is the maximum allowable 

output temperature (usually 110° - 112°F).  
Reinstall the stop ring so that it buts against the stop.  

Reinstall the clip. 

Set the High Temperature Limit Stop (optional)

Justify the Thermostatic Mixer Handle

Turn on the water to the handshower.
Place a thermometer in the water stream.  Turn the thermo-

static mixer handle until the water coming out measures 

100°F.  Turn the water off.

Save time and frustration:

 if turning the thermostatic 

mixer handle gives both hot and cold water, 

but

 the 

water does not mix, the hoses have been connected to the 

incorrect supplies.  Please disconnect the hoses, reattach 

them to the correct supplies and test the unit 

before

 

calling the Hansgrohe Technical Service center.

Remove the thermostatic mixer handle and the safety set.  

Reinstall the safety set so that the indicator is at the 12:00 

position.  
Reinstall the handle so that the safety stop override button 

is at the 12:00 position.  
Tighten the handle screw and replace the screw cover.  

Содержание Starck 10920001

Страница 1: ...Starck X 10920001 Installation Instructions Warranty...

Страница 2: ...utlet The high temperature limit stop may be reset to comply with local plumbing codes See page 5 This unit is listed by IAPMO and is approved for use in Massachusetts Please save this document as it...

Страница 3: ...of the Waterwall Flush the supply lines thoroughly before installation Installation Drill the holes for the top and bottom mounting brack ets using a 6 mm bit Install the anchors Seal around the anch...

Страница 4: ...ach the hoses to the elbows Install the bottom retaining screw and tighten with a screwdriver Carefully install the showerhead on the shower arm Insert a hose washer in one end of the handshower hose...

Страница 5: ...rmometer in the water stream Turn the thermo static mixer handle until the water coming out measures 100 F Turn the water off Save time and frustration if turning the thermostatic mixer handle gives b...

Страница 6: ...head and handshower use the Quick Clean self cleaning function If scale deposits are noticed in the spray channels turn the water on lightly and rub across the chan nels with a finger or a sponge to c...

Страница 7: ...o comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and...

Страница 8: ...date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkwa...

Отзывы: