0 2
A S S E M B L Y ( S E E P A G E 0 4 )
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C ⁄ 4 min
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
D I M E N S I O N S (see page 07)
F L O W D I A G R A M (see page 07)
free flow
S P A R E P A R T S (see page 10)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
25 = Brushed Gold-Optic
30 = Polished Redgold
31 = Brushed Redgold
33 = Polished Black Chrome
34 = Brushed Black Chrome
67 = Matt Black
80 = Stainless Steel Optic
82 = Brushed Nickel
95 = Brushed Brass
99 = Polished Gold-Optic
S P E C I A L A C C E S S O R I E S
(see page 11)
order as an extra
⁄ extension 25 mm #13595000
⁄ Extension Set 33 mm (when wall is not deep
enough) #14961XXX, #14972XXX
C L E A N I N G (see page 09)
O P E R A T I O N (see page 08)
+
F A U L T
C A U S E
R E M E D Y
⁄ Mixer stiff
⁄ Cartridge defective, calcified
⁄ Exchange cartridge
⁄ Mixer dripping
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Hot water temperature too low, no cold
water. Instantaneous water heater starts
up when cold water is selected.
⁄ Hot water limiter incorrectly set
⁄ Set hot water limiter
⁄ Crossflow
⁄ Exchange cartridge
⁄ Diverter not operating
⁄ Residue
⁄ Clean converter ⁄ grease O-rings
⁄ Water pressure to low
⁄ Increase water pressure
⁄ Diverter defective
⁄ Exchange diverter