Install the pop-up drain

Remove the plunger assembly.

Unscrew the drain outlet flange from the tee.

Unscrew the tailpiece from the tee.  Wrap the 

threads with plumbers’ thread tape and replace. 

Install the white, flexible sealing gasket to the 

flange.  Place it in the sink outlet. 

From under the sink, install the black mack gas-

ket, white friction ring  and retainer nut  to the 

flange. Do not tighten the nut against the bottom 

of the sink at this time.

Thread the tee and tailpiece to the flange.  The 

pivot must face the faucet.  If necessary, turn the 

drain assembly.

Tighten the retainer nut.  

Place the plunger assembly in the drain. 

Install the horizontal rod so that the end goes 

through the loop in the bottom of the height 

adjuster.

Install and hand tighten the pivot ball nut.

Attach the swivel connector to the end of the 

horizontal rod.  

Attach the swivel connector to the end of the 

pull rod.   Position as desired and tighten with a 

small, flathead screwdriver.

plunger

flange

sealing gasket

mack gasket

friction ring

retainer nut

horizontal rod

height adjuster

pivot ball nut

swivel connector

pull rod

tee

Содержание Citterio 39154XX1

Страница 1: ...Citterio 39234XX1 Citterio 39134XX1 39154XX1 Installation Instructions Warranty...

Страница 2: ...unicipalities limit the maximum water temperature from the water heater to 120o or below Please know and follow all applicable local codes when setting the temperature on the water heater Prepare to i...

Страница 3: ...en wrench to install and tighten the spout retaining screws Place the spout and handle assembly over the valve bodies Tighten the valve mounting screws Install the drain pull rod Place the spout mount...

Страница 4: ...e mounting angle Place a compression nut and washer over the shank end of one of the connection hoses Attach the hose to the outlet port on the valve with the compression fitting Tighten with a wrench...

Страница 5: ...ead the tee and tailpiece to the flange The pivot must face the faucet If necessary turn the drain assembly Tighten the retainer nut Place the plunger assembly in the drain Install the horizontal rod...

Страница 6: ...turn the hot water off Replacement Parts 1 handle 39291XX0 2 cold escutcheon 96679XX0 3 hot escutcheon 96678XX0 4 escutcheon 96680XX0 5 Stop unit left closing 94008000 6 aerator lavatory 96673000 7 a...

Страница 7: ...ates or Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only This warranty is non transferable WHAT IS COVERED BY THE WARRANTY This warranty covers only...

Страница 8: ...ASER HANSGROHE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY PERSON FOR ANY I...

Отзывы: