T E C H N I C A L D A T A
This thermostatic valve will suit supplies of:
HIGH PRESSURE (HP-S)
Operating pressure:
max. 10 bar
Recommended operating pressure:
1 - 5 bar
Test pressure:
16 bar
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow:
25 l⁄min. @ 3 bar
Maximum outlet temperature:
43°C +⁄-*
Safety check:
40°C
Hot water connection:
Left hand
Cold water connection:
Right hand
Minimum difference between hot
water and mixed water temperature:
6 K
Hot and cold supply pressure should be balanced
Mixed water temperature
Application
Mixed water temperature
(at point of discharge).
Shower
41°C max.
Washbasin
41°C max.
Bath (44°C fill)
44°C max.
Bath (46°C fill)
46°C max.
* For preset outlet temperature adjustment – See page
63.
NB. If a water supply is fed by gravity then the supply pressure
should be verified to ensure the conditions of use are appropriate
for the valve. Valves operating outside of these supply conditions
cannot be guaranteed to operate as a TMV2 or TMV3 valve.
Recommended outlet temperatures
The BuildCert TMV scheme recommends the following set ma-
ximum mixed water outlet temperatures for use in all premises:
44°C for bath fill but see notes below;
41°C for showers;
41°C for washbasins.
The mixed water temperatures must never exceed 46°C.
The maximum mixed water temperature can be 2°C above the
recommended maximum set outlet temperatures.
Note: 46°C is the maximum mixed water temperature from the
bath tap. The maximum temperature takes account of the allowa-
ble temperature tolerances inherent in thermostatic mixing valves
and temperature losses in metal baths.
It is not a safe bathing temperature for adults or children.
The British Burns Association recommends 37 to 37.5°C as a
comfortable bathing temperature for children. In premises covered
by the Care Standards Act 2000, the maximum mixed water
outlet temperature is 43°C
I N S T A L L A T I O N R E Q U I R E M E N T S
This thermostatic mixer valve must be installed in
compliance with current Water Regulations. If you have any
doubts about the Water Regulation requirements contact
your local water services provider or use the services of a
professional plumber.
This mixer valve is suitable for use with the following water
supply systems:
Gas Combination Boiler (multi-point) 1.0 - 10 bar*
Unvented System (pressure balanced) 1.0 - 10 bar
Pumped System 1.0 - 10 bar
IMPORTANT: If you install this mixer with a gravity fed
system, there must be a minimum head (vertical distance)
from the underside of tlie cold water storage tank to the
showerhead position of at least 5 metre.
Before connecting the mixer, water should be flushed
through the system to remove all debris that might otherwise
damage the valve.
* If pressure is in excess of 3.5 bar, a pressure-reducing
valve should be fitted.
Operating pressure range
High pressure
Maximum static pressure - bar
10
Flow pressure, hot and cold - bar
1 to 5
Hot supply temperature - °C
52 to 65
Cold supply temperature - °C
5 to 20
S U P P L Y C O N D I T I O N S T M V 2
S U P P L Y C O N D I T I O N S T M V 3
Operating pressure range
High pressure
Maximum static pressure - bar
10
Flow pressure, hot and cold - bar
0.5 to 5
Hot supply temperature - °C
55 to 65
Cold supply temperature - °C
5 to 25
Содержание Carlton 17705 Series
Страница 25: ...2 5 79 64 65 68 ZH A 42 C 65 C 180 180 68...
Страница 27: ...2 7 79 64 65 68 c RU A 42 65 180 68...
Страница 43: ...4 3 79 64 65 68 EL A 42 C 65 C 180 180 68...
Страница 55: ...5 5 79 64 65 68 c BG A 42 C 65 C 180 180 68...
Страница 58: ...5 8 AR 79 64 65 68 A 42 65 180 180 68...
Страница 60: ...6 0 X 11 1 2 mm 1 1 2 2 4 3 5 6 2 2 3 1 1 SW 4 mm 5 Nm X 01700180 1 2 mm...
Страница 63: ...6 3 z B 42 C for example 42 C S W 3 m m 4 N m 1a 1b 2 SW 2 mm SW 2 mm S W 3 m m 3 4 5 6 1 1 2 2...
Страница 64: ...6 4 40 C 7 8a 8b SW 2 mm 4 Nm SW 2 mm 4 Nm 1 2...
Страница 66: ...6 6 SW 4 mm 1 2 3 4 1a 2 3 4 1 1 2 3 4 1b SW 2 mm SW 2 mm S W 3 m m S W 3 m m 5 6 SW 27 mm 7 1 2...