9
5
Settings Menu
Introduction
The settings menu displays the current state of each setting within
the HDR07 and enables the item to be changed or adjusted.
Settings can be changed using the front panel of the Synapse
frame (SFR18, SFR08 or SFR04) or Axon Cortex software.
PLL_Set
The HDR07 is capable of re-clocking a range of SDI and HDSDI
transport stream bitrates.
PLL_Set
is used to set the HDR07 to
the correct bitrate of the incoming SDI or HDSDI signal.
PLL_Set
can be set to
Autodetect
,
143Mb/s
,
177Mb/s
,
270Mb/s
,
360Mb/s
,
540Mb/s
and
1485Mb/s
.
The default setting is
Autodetect
.
Reclock
The setting item
Reclock
determines if the incoming signal will
be reclocked by the HDR07. The settings are;
Automatic
: Auto selection between
Bypass
and
Reclocked
.
Bypass
: Does not re-clock the incoming signal
Reclocked
: The HDR07 always attempts to re-clock the
incoming signal.
The default setting is
Automatic
.
ASI_177
The setting item
ASI_177
allows an incoming signal of 177Mb/s
to be handled. When
ASI_177
is switched
Off
an incoming
signal with a bit rate of 177Mb/s will not be detected by
PLL_Set
.
The Default setting is
On
.
DDOmute
DDOmute
(Direct Digital Out mute) enables the outputs of the
HDR07 to be muted. The settings are
On
,
Off
,
Input Loss
or
PLL Unlock
. Set to
Input Loss
will mute only in case a
carrier loss is detected on the input. Set to
PLL unlock
will
mute the outputs in case the PLL rate of the input is not available.
The Default setting is
Off
.