APPENDIX1: RS232 PROTOCOL 

 

Baud Rate = 9600 

Command Structure: <command><zone><data>line feed.  
Characters are all ASCII

 

Command 

 

Command Description 
01 

Standby 

02 

Mute 

03 

Source Selection 

04 

Volume 

05 

Bass 

06 

Treble 

07 

Balance 

09 

Send All parameters 

0B 

Cause key press on Keypad 

0C 

Amplifier features 

0D 

Volume Limit 

0E 

Preset Call 

0F 

Track Zone 

10 

Unsupported IR command received 

60 – 6F  

User defined IR commands, no data byte 

70 – 7F 

User defined IR commands, one data byte 

 

 
Zone 

 

Axium amplifiers and keypads are encoded with up to 32 zones (00 – 31
All amplifier zones may be addressed by sending the FF characters 
 
 

Data   

 

 

 

 

 

 

 

 

 

Command Content 
Standby 

00 – Standby A OFF 
01 – Standby A ON 
02 – Standby B OFF 
03 – Standby B ON 

Mute 

00 – Mute 
01 – Un-mute 

Source 
Selection 

00 – Select CD 
01 – Select Tape 
02 – Select Tuner 
03 – Select Auxiliary 
04 – Select Mono utility input 

Volume 

00 – A0 range 

Bass 

F4 – 0C (-12db - +12db) 

Treble 

F4 – 0C (-12db - +12db) 

Balance 

EC – 14 (Left –20db – Right –20db) 

Amplifier 
features 

00 – Loudness enabled 
01 – Loudness disabled 

Volume Limit 

00 – A0 range 

Preset 

00 – Standard mode 
11 – Force Preset 

Track Zone 

00 – 31 zone to be tracked 
FF – for no zone tracking 

Содержание AX250i

Страница 1: ...INSTALLATION OPERATION MANUAL AX250i Two Zone Two Stereo Pre Amplifiers Amplifiers With RS232 Keypad IR Control Total In Home Connectivity ...

Страница 2: ...products are built to the highest standards of quality and reliability To view Axium s product line of Multizone Amplifiers controllers accessories please visit the Website at www axium co nz You may also download the latest control software Table Of Contents INTRODUCTION 1 FEATURES 2 INSTALLATION QUIDE 4 FRONT PANEL OPERATION 5 REAR PANEL CONNECTIONS 6 SPECIFICATIONS 8 APPENDIX1 RS232 PROTOCOL 9 ...

Страница 3: ...imit setting zone tracking See the features section of the manual A utility program called AMPCTRL is available from the Axium website this gives users complete access and control of all Axium networked components and even provides the ability to schedule events from your personal computer Axium Multizone amplifiers may be interconnected via the expansion bus providing up to 32 zones of control an...

Страница 4: ... and 12VDC outputs on the rear panel connector The output s are protected against shorts and back EMF voltage surges which may occur if powering a relay Summed Amp On A Summed Amp On 12VDC output is provided on the rear panel connector This is typically used to switch the Audio source component s AC power If any amplifier Zone or Speaker output in an Axium amplifier stack is ON then this output wi...

Страница 5: ...lly this is to prevent reckless use of the system or prevent destruction of speakers when powered by a slave amplifier Global IR commands There is a range of Global IR commands available for turning All amplifiers either On Off or selecting various audio sources There are also Force and Release Preset commands that invoke a user programmed Amplifier preset Global Preset One Preset may be programme...

Страница 6: ...an flow freely and escape from the amplifier surroundings Failure to do so may cause intermittent channel cutout and reduced life expectancy 3 Under no circumstances should the speaker output terminals of the unit be short circuited or connected to another output 4 Never plug the RS232 cable into the unit while power is connected 5 Never short the 10 way controller connector terminals These should...

Страница 7: ...utton until the BASS indicator LED is illuminated You can then increase or decrease the BASS by pressing the VOL UP increase or DOWN decrease The FUNCTION level value is indicated on the 2 digit display The Zone is selectable between 0 31 and must be set in memory by pressing the SELECT button FUNCTION mode is terminated after 4 seconds of inactivity or by toggling past the last FUNCTION ZONE STAN...

Страница 8: ... have volume pads installed and a slave amplifier is required to operate the network at full power PRE OUT is the Zone 1 post fader output Output level is dependant on the volume control The output is muted when Zone 1 is muted PRE OUT may be used to drive a high power Slave amplifier or Active Sub Woofer IR Out A 3 5mm phono socket provides direct connection for IR emitters The output is individu...

Страница 9: ...On 12V This is used to switch power sockets for connecting AC power to Audio source components i e CD players Tuners etc Amp ON A If Speaker A Zone 1 is ON then output will be 12V Current limited 25mA Amp On B If Speaker B Zone 1 is ON then output will be 12V Current limited 25mA Amp On C If Speaker C Zone 2 is ON then output will be 12V Current limited 25mA Amp On D If Speaker D Zone 2 is ON then...

Страница 10: ...s control range 12db Treble control range 12db Balance control range 19db Loudness boost Gain 50db 6db 40Hz Volume control range 86db 0db 2 5db steps Mute attenuation 100db Amplifier Output power 8 ohm load 50W RMS Output power 4 ohm load 75W RMS Slew Rate 10V µs THD 8ohm load 1KHz 5Watt 0 01 IR range 9 m 30degrees off horizontal axis Dimensions Width 435mm 17 Height 112mm 4 2 5 Depth 340mm 13 2 5...

Страница 11: ...byte Zone Axium amplifiers and keypads are encoded with up to 32 zones 00 31 All amplifier zones may be addressed by sending the FF characters Data Command Content Standby 00 Standby A OFF 01 Standby A ON 02 Standby B OFF 03 Standby B ON Mute 00 Mute 01 Un mute Source Selection 00 Select CD 01 Select Tape 02 Select Tuner 03 Select Auxiliary 04 Select Mono utility input Volume 00 A0 range Bass F4 0...

Страница 12: ...one X Example strings 010801 Standby A ON command for Zone 8 060002 2db Treble setting on Zone 0 033102 Tuner source selection on Zone 31 0B0311 Volume down continuous push on Zone 3 keypad Keypad key codes An Axium Keypad may be directed to emit its learnt IR commands via RS232 control This is achieved by sending a Cause key press on Keypad command followed by the zone and the Keypad key code dat...

Страница 13: ...cally or as single events A keypad Macro may also be programmed as part of the Schedule An Axium Keypad connected to an amplifier may be controlled causing the keypad to emit it s learnt IR strings Thus Audio Source CD Tuner etc control may be achieved via the AMPCTRL program The Keypads programming file may be imported from AxiumIR Keypad and Remote control program providing button ID s For a ful...

Отзывы: