background image

 
 

 

 

 

3/12 

AXITEC INSTALLATION 

– USA 170727 

INTRODUCTION 

Thank you for choosing AXITEC LLC PV modules. With proper operation and maintenance, AXITEC LLC 

modules will provide you with clean and renewable solar electricity for years. This manual contains 

necessary installation, maintenance and safety 

information. The word “module” as used in this manual 

refers to one or more PV modules. Retain this manual for future reference.

 

DISCLAIMER OF LIABILITY 

AXITEC LLC does not assume responsibility and expressly disclaims liability for any loss, damage, or 

expense arising out of, or in any way connected with installation, operation, use, or maintenance by using 

this manual. AXITEC LLC assumes no responsibility for any infringement of patents or other rights of third 

parties, which may result from use of modules. No license is granted by implication or under any patent or 

patent rights. The information in this manual is reliable, but does not constitute an expressed and/or implied 

warranty. AXITEC LLC reserves the right to make changes to the product, specifications, or this manual 

without prior notice. Without any prior written authorization, AXITEC LLC will not accept any returned 

modules. 

GENERAL INFORMATION 

The installation of solar modules must only be performed by skillful and qualified professionals. 

SAFETY  

Follow all permission, installation and inspection requirements. 

 

Must contact the appropriate authorities to determine permissions, installation and inspection 

requirements to follow that apply to your site and installation before installing modules/system. 

 

Check applicable building codes to ensure that the construction or structure (roof, façade, support, 

etc.) where the modules are installed do have enough strength. 

 

Special construction or structures must be required to help provide proper installation support in the 

case of modules mounted on roofs. 

 

Both roof construction and module installation design have an effect on the fire resistance of a 

building. Improper installation will cause fire hazards. Additional devices such as ground faults, 

fuses, and disconnects may also be required. 

 

Do not use different modules in the same mounting system. 

 

Check and follow all safety precautions of other system components. 

Содержание 60-CELL

Страница 1: ...1 12 AXITEC INSTALLATION USA 170727 Installation Manual AXITEC SOLAR MODULES ...

Страница 2: ...ONS 5 2 INSTALLATION AND OPERATION 5 3 MECHANICAL INSTALLATION 5 3 1 60 CELL MODULES 6 3 2 72 CELL MODULES 7 3 3 MOUNTING WITH BOLTS 8 3 4 MOUNTING WITH CLAMPS 9 3 5 GROUNDING 9 4 ELECTRICAL INSTALLATION 9 4 1 GENERAL WIRING 9 4 2 MODULE WIRING 10 4 3 ARRAY WIRING 10 5 JUNCTION BOX AND TERMINATION 10 6 MAINTENANCE 11 7 SPECIFICATION 11 7 1 ELECTRICAL SPECIFICATION Typical 11 7 2 GENERAL SPECIFICAT...

Страница 3: ...o make changes to the product specifications or this manual without prior notice Without any prior written authorization AXITEC LLC will not accept any returned modules GENERAL INFORMATION The installation of solar modules must only be performed by skillful and qualified professionals SAFETY Follow all permission installation and inspection requirements Must contact the appropriate authorities to ...

Страница 4: ...dry modules and tools Do not break the glass surfaces of modules Do not drop a module Do not allow children and unauthorized persons near the installation site or storage area of modules All modules have been complete grounding to earth with electrical insulation Do not open the cover of the junction box Do not disassemble the module or remove any part installed by the manufacturer Wear suitable p...

Страница 5: ...dule Although AXITEC LLC modules are quite rugged the glass may be broken and the module will no longer work properly if it is dropped or hit by tools or other objects Sunlight shall not be concentrated on the module The module frames is made of anodized aluminum and therefore corrosion can occur if the module is placed in a salt water environment with contact to a rack of an other type of metal E...

Страница 6: ...6 12 AXITEC INSTALLATION USA 170727 3 1 60 CELL MODULES Figure 1 A distance 7 87 inch 200 mm B clamping zone 7 87 inch 200 mm C clamping zone 11 81 inch 300 mm D clamping zone 7 87 inch 200 mm ...

Страница 7: ...7 12 AXITEC INSTALLATION USA 170727 3 2 72 CELL MODULES A distance 11 42 inch 290 mm B clamping zone 7 87 inch 200 mm ...

Страница 8: ...e mounted on the roof of a building The modules are supported parallel to the surface of the building roof To prevent wiring damage and to allow air to circulate behind the module clearance between the module frames and surface of the roof is required The standoff minimum height is 3 9 inch about 100 mm refer to Figure 2 If other mounting means are employed this may affect the listing for fire cla...

Страница 9: ...grounded in accordance with the appropriate respective National Electrical Code Proper grounding is achieved by bounding the module frame and all metallic structural members together continuously using a suitable grounding conductor The grounding conductor or strap may be copper copper alloy or other material acceptable for use as an electrical conductor per respective National Electrical Codes Th...

Страница 10: ...and temperature rating of the conductors to be used Size 12AWG Type Tinned fine copper strands according to VDE 0295 IEC60228 class 5 Temperature rating 40 C up to 125 C 4 3 ARRAY WIRING Use copper wire only Cu only that is sunlight resistant and is insulated to withstand the maximum possible system open circuit voltage For use with non metallic wiring systems only For field connections use minimu...

Страница 11: ...and VOC marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor ampacity fuse sizes and size of controls connected to the PV output Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable 7 2 GENERAL SPECIFICATION Axitec LLC reserves the right t...

Страница 12: ...12 12 AXITEC INSTALLATION USA 170727 AXITEC LLC 1819 Underwood BLVD Suite 5 Delran New Jersey 08075 United States of America www axitecsolar us This document is subject to change without notice ...

Отзывы: