Axis S2008 Скачать руководство пользователя страница 15

AXIS Camera Station S20 Appliance Series

Manage the built-in switch

DHCP server

Enabled

The status of the DHCP server.

When the DHCP server is disabled, you must assign IP addresses manually
to the cameras or use an external DHCP server accessible via the U1
network connection for IP assignment.

Start IP address

End IP address

When DHCP is enabled, you can choose a

Start IP address

and

End IP

address

range for assignment of attached devices

Subnet mask

The subnet mask of the U1 switch connection.

Gateway

The gateway to access the U1 switch connection.

DNS 1

The primary domain name server used by the switch.

DNS 2

An alternate domain name server used by the switch.

Lease length

The suggested length of time in minutes that the DHCP server will use for
potentially reassigning its pool of dynamic IP addresses. The minimum
lease length is 60 minutes.

Admin tab

In the

Admin

tab, you find information about the firmware version. In this tab you can also change the password, backup settings

and reboot the switch.

Pane

Function

Description

Security

Username

Password

New password

Confirm new password

These fields allow you to set the password for the switch administrator.

The switch only has one user:

admin

.

The factory default password is

system

.

Firmware

Version

The installed firmware version.

Upgrade firmware

Allows you to update the firmware to a new version.

Maintenance

Reset to factory default

Resets all switch settings to factory default values.

Reboot switch

Reboots the switch. While rebooting, all devices will temporarily lose
connection with the switch (including PoE).

Backup settings

Stores a backup of your settings in a file in the

Downloads

folder of

your browser.

Restore settings

Allows you to select a saved backup file to restore settings.

15

Содержание S2008

Страница 1: ...AXIS Camera Station S20 Appliance Series AXIS Camera Station S2008 Appliance AXIS Camera Station S2016 Appliance AXIS Camera Station S2024 Appliance User Manual...

Страница 2: ...r used ports 7 How to improve security for unused ports 8 How to configure the switch s IP address 8 How to configure the DHCP server 8 How to reset the switch to factory default settings 9 How to cha...

Страница 3: ...ding the video management software AXIS Camera Station The built in Power over Ethernet PoE switch simplifies installation and maintenance AXIS Camera Station S20 Appliance Series consists of three di...

Страница 4: ...n The built in switch s DHCP server is enabled by default As soon as you plug the cameras into the PoE ports the cameras will power on and obtain an IP address and be accessible via AXIS Camera Statio...

Страница 5: ...network eSATA connector USB 2 0 connector x2 front panel Use AXIS Camera Station S20 Appliance in an existing network You can create a surveillance network within an existing network This means that t...

Страница 6: ...IS Camera Station license Connectors used PoE enabled network connectors port 1 8 U2 server network for connection to network Optional USB 3 0 connector x2 for keyboard and mouse Optional VGA or HDMI...

Страница 7: ...s priority where a lower port number means higher priority How to open the switch s webpage 1 From your desktop open the Get Started application and go to PoE Switch 2 Click Go to PoE switch website 3...

Страница 8: ...If you ve forgotten the new IP address contact Axis support Note The factory default settings are a static IP connection with address 192 168 50 1 and a subnet mask with address 255 255 255 0 1 Open t...

Страница 9: ...page 2 Go to Admin Security 3 Enter User name and Password 4 Enter the New password and confirm it 5 Click Save 6 Reboot the switch How to backup the switch s settings Note The username and password a...

Страница 10: ...Open the switch s webpage 2 Go to VLAN and click Add 3 Select which port uplink or CPU connections you want to add to the new VLAN Each port uplink or CPU connection can only belong to one VLAN at a...

Страница 11: ...negotiated link speed for each port Transmit rate An overview of traffic load on each port showing the average data rate in megabits per second for outbound data on the port Receive rate An overview...

Страница 12: ...power draw of the connected device PoE Class values range from 0 to 4 and correspond to the following properties as defined in the IEEE standard Cl ass Usage Classifica tion Current mA Power Range wat...

Страница 13: ...switch automatically detects the MAC address of any device connected to the port and displays it here Data traffic will only be allowed to or from this MAC address Bound MAC addresses Enabling ACL wil...

Страница 14: ...rty or self signed if any To update certificates or any of the information in this pane once new certificates or keys are provided you must reboot the switch Once rebooted the switch will display the...

Страница 15: ...g its pool of dynamic IP addresses The minimum lease length is 60 minutes Admin tab In the Admin tab you find information about the firmware version In this tab you can also change the password backup...

Страница 16: ...ion S20 Appliance Series Product overview Product overview Front Panel AXIS Camera Station S20 Series 1 USB 2 0 connector x2 not used 2 System power LED 3 Disk activity LED 4 Status LEDs PoE port 1 8...

Страница 17: ...plink RJ45 connector 4 SFP 1 switch uplink SFP connector 5 U2 server network RJ45 connector 6 USB 3 0 connector x2 7 SFP 2 server network SFP connector 8 eSATA connector 9 HDMI connector audio output...

Страница 18: ...User Manual Ver M2 15 AXIS Camera Station S20 Appliance Series Date November 2017 Axis Communications AB 2016 2017 Part No T10084515...

Отзывы: