Страница 3: ...ra Package contents AXIS Q6055 S PTZ Dome Network Camera AXIS T8607 Media Converter Switch Multicable IP66 7 m 23 ft DIN rail clip Printed materials Installation Guide this document Extra serial number label 2x AVHS Authentication key 3 ...

Страница 4: ...ations on page 19 NO NO NOTICE TICE TICE Make sure the dome is attached in operation mode otherwise focus may be affected 1 Pressure relief valve 2 Multiconnector 3 Hook for safety wire 4 Inlet valve 5 Mounting hole 3x 6 Part number P N Serial number S N 7 Dome 8 SD card slot SDHC 9 Status LED indicator 10 Control button 4 ...

Страница 5: ...AXIS Q6055 S PTZ Dome Network Camera 1 Dome attachment ring 2 O ring 3 Dome bracket screw T20 4x 4 Dome 5 O ring 6 Dome ring 7 Dome ring screw T25 4x 5 ...

Страница 6: ...output 3 Network connector internal 4 Network connector SFP external 2x 5 Network connector RJ45 external 2x 6 Camera network LED indicator 7 Network LED indicator 4x 8 Power LED indicator 9 Ground clip 10 I O connector internal 11 I O connector external 12 Multicable 13 Ground screw 6 ...

Страница 7: ...ard Be careful not to scratch damage or leave fingerprints on the dome cover because this could decrease image quality If possible keep the protective plastic on the dome cover until the installation is complete The product can be mounted with the cables routed through or along the wall or roof Recommended tools NO NO NOTICE TICE TICE Stainless steel is corrosion resistant but extraneous rust can ...

Страница 8: ...eated three times releasing the pressure between fillings to make sure that all air and humidity is purged from the housing Note The camera housing has an pressure relief valve that limits the filling pressure to 0 5 bar 7 psi During normal use the pressure inside the camera housing may drop below that pressure For full protection make sure that the pressure is above 0 2 bar 3 psi 1 Set the regula...

Страница 9: ...y and the media converter switch shall be installed in an environment protected against dust and water for example indoors or in an appropriate cabinet Important Axis can only guarantee full functionality with the supplied media converter switch No other devices are supported 1 Make sure the mains supply is switched off 2 Mount the power supply and the media converter switch on the wall or if appl...

Страница 10: ...thernet wire foil shields 7 Strip off about 4 5 mm 0 16 0 20 in of the power wire jackets 1 Multicable jacket 2 Braided shield 3 Ethernet wire foil shield 2x 8 Connect the network and I O wires to the internal network and I O connectors Open the lid insert the wires and close 9 Connect the ground and power wires to the power connector DC output 10 ...

Страница 11: ...et wire orange 7 Digital I O wire yellow 8 Ground wire black 9 Power wire red 10 Power connector DC output 11 Ethernet connector internal 12 Ethernet connector internal 13 I O connector internal 14 Braided shield coil 15 Ethernet wire shield 2x 16 Clamp 10 Make sure the clamp is in place insert the braided shield coil into the ground clip and tighten the screws 11 ...

Страница 12: ...sure all surfaces and contacts are clean and free from scrap shield material 11 Connect the network cables to the external network connectors RJ45 SFP as required Note An SFP module not included has to be used when connecting an optical fiber cable 1 Power cable DC input 2 Power connector DC input 3 Network connector SFP external 2x 4 Network connector RJ45 external 2x 5 I O connector external 6 M...

Страница 13: ...onnects to another media converter switch to position C Leave the dip switch in its default position position B when connecting the port directly to the network For more information see Media converter switch connectors on page 22 Important If the system is not defined use the default dip switch setting position B 1 Dip switch 4x 16 Attach the cover to the media converter switch 17 Switch on the m...

Страница 14: ...esign of the camera and maintain the IP66 protection the supplied multicable shall be used 1 Install the selected bracket according to the instructions supplied with the bracket If drilling is required make sure to use drill bits screws and plugs that are appropriate for the material 2 Route the multicable through the holes in the mounting bracket 3 Secure the camera using the supplied safety wire...

Страница 15: ...tion cap covering the multiconnector on the camera 5 Connect the multicable to the connector on the camera Use the alignment indicators to find the correct position NO NO NOTICE TICE TICE Be careful not do damage the multicable when connecting it 6 Fasten the network camera to the mounting bracket with the screws 15 ...

Страница 16: ...thods for finding Axis products on the network and assigning them IP addresses in Windows Both applications are free and can be downloaded from www axis com support The product can be used with most operating systems and browsers We recommend the following browsers Internet Explorer with Windows Safari with OS X ChromeTM or Firefox with other operating systems For more information about using the ...

Страница 17: ...the status LED indicator flashes amber 4 Release the control button The process is complete when the status LED indicator turns green The product has been reset to the factory default settings If no DHCP server is available on the network the default IP address is 192 168 0 90 5 Using the installation and management software tools assign an IP address set the password and access the video stream T...

Страница 18: ... com The user manual is available at www axis com To check if there is updated firmware available for your product see www axis com support For useful online trainings and webinars see www axis com academy Optional accessories For a complete list of available accessories for this product go to www axis com 18 ...

Страница 19: ...Color Indication Unlit DC power unconnected or current protection engaged power overload Power Green DC power connected Amber 10 Mbit connection Flashes during activity Network 4x Green 100 1000 Mbit connection Flashes during activity Camera network only available on AXIS T8607 Green 100 Mbit connection Flashes during activity SD card slot NO NO NOTICE TICE TICE Risk of damage to SD card Do not us...

Страница 20: ...services see the User Manual Connectors Multiconnector Terminal connector for connecting the supplied media converter switch which provides the following signals DC Power Network Ethernet 10 100Base T Input Output I O Multicable connectors Note The supplied multicable is required in order to maintain the camera s NEMA IP rating The multicable is connected to the camera s multiconnector see Hardwar...

Страница 21: ...rnet wire foil shield 2x 11 Braided shield coil Function Wire Connect to Specifications Digital input I O terminal connector 0 to max 30 V DC Configurable Input or Output 2 blue 7 yellow Digital output I O terminal connector 0 to max 30 V DC open drain 100 mA RX 3 green white Ethernet receiving RX 4 green Ethernet receiving TX 5 orange white Ethernet transmitting TX 6 orange Ethernet transmitting ...

Страница 22: ...ctions For information about regulatory requirements see Electromagnetic compatibility EMC on page 32 Important The media converter switch does not support hotswapping Disconnect power from the switch before swapping cameras An attempt to hotswap could cause the switch to freeze in which case it must be restarted Camera connectors Power connector Two 2 pin terminal blocks for power output pin 4 is...

Страница 23: ...ith their respective grounding surfaces Power connector 2 pin terminal block for power input Function Pin Notes 0 V DC 1 DC input 24 V DC 2 Power in from power supply sold separately Network connector RJ45 Two RJ45 connectors 10 100Base T for network Network slot SFP Two SFP slots 100Base FX 1000Base X for network Each RJ45 and SFP port has its own dip switch The dip switches control how the port ...

Страница 24: ...eak detectors etc When a signal is received the state changes and the input becomes active shown under System Options Port Devices Port Status 6 pin terminal blocks for Digital Input Output Power DC output 0 V DC Function Pin Notes Specifications 0 V DC 1 4 6 0 V DC DC output 2 Power out 12 V DC 50 mA Digital input 0 to max 30 V DC Configurable I O 1 Input or Output 3 Digital output transistor ope...

Страница 25: ...te independent logical networks virtual local area networks VLANs within a physical network Multiple media converter switches that are connected to each other in a daisy chain are members of the same VLAN The media converter switches tag the multicast packages moving between them so that the next media converter switch in line knows the destination of the packages In other words the VLAN tag serve...

Страница 26: ...rical specifications NO NO NOTICE TICE TICE For confirmed compliance with the requirements for Safety Extra Low Voltage SELV and Limited Power Source LPS use the power supply sold separately recommended by Axis For information about compatible power accessories see www axis com Product Function Description Network camera Input power 24 V DC min 65 W Input voltage 24 V DC Input power min 75 W Avail...

Страница 27: ...AXIS Q6055 S PTZ Dome Network Camera 1 Media converter switch 2 Multicable 3 Network camera 27 ...

Страница 28: ...28 ...

Страница 29: ...lt in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not avoided could result in damage to property Other message levels Important Indicates significant information which is essential for the product to function correctly Note Indicates useful information which helps...

Страница 30: ...with the technical specification of your product These can be provided by Axis or a third party Axis recommends using Axis power source equipment compatible with your product Use only spare parts provided by or recommended by Axis Do not attempt to repair the product yourself Contact Axis support or your Axis reseller for service matters Do not point the camera lens toward the sun or other high in...

Страница 31: ... which is recommended by Axis Dispose of used batteries according to local regulations or the battery manufacturer s instructions Dome Cover NO NO NOTICE TICE TICE Be careful not to scratch damage or leave fingerprints on the dome cover because this could decrease image quality If possible keep the protective plastic on the dome cover until the installation is complete Do not clean a dome cover th...

Страница 32: ...LLC in the United States other countries or both Also miniSD microSD miniSDHC microSDHC microSDXC are all trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Regulatory information Europe This product complies with the applicable CE marking directives and harmonized standards Electromagnetic Compatibility EMC Directive 2014 30 EU See Electromagnetic compat...

Страница 33: ...e 2012 19 EU on waste electrical and electronic equipment WEEE is applicable in the European Union member states To prevent potential harm to human health and the environment the product must be disposed of in an approved and environmentally safe recycling process For information about your nearest designated collection point contact your local authority responsible for waste disposal Businesses s...

Страница 34: ...Installation Guide Ver M3 3 AXIS Q6055 S PTZ Dome Network Camera Date March 2017 Axis Communications AB 2016 2017 Part No 1650686 ...

Отзывы: