background image

AXIS Q3505–VE Fixed Dome Network Camera

Note

The installation and management software tools are available on the CD supplied with the
product and from the support pages on

www.axis.com/techsup

To reset the product to the factory default settings:

1. Disconnect power from the product.
2. Press and hold the control button and reconnect power. See

Hardware Overview on

page 10

.

3. Keep the control button pressed for about 15–30 seconds until the status LED indicator

flashes amber.

4. Release the control button. The process is complete when the status LED indicator turns

green. The product has been reset to the factory default settings. If no DHCP server is
available on the network, the default IP address is

192.168.0.90

5. Using the installation and management software tools, assign an IP address, set the

password, and access the video stream.

It is also possible to reset parameters to factory default via the web interface. Go to

Setup

> System Options > Maintenance

.

Further Information

The User Manual is available at

www.axis.com

Visit

www.axis.com/techsup

to check if there is updated firmware available for your network

product. To see the currently installed firmware version, go to

Setup > About

.

Visit Axis learning center

www.axis.com/academy

for useful trainings, webinars, tutorials and

guides.

Warranty Information

For information about Axis’ product warranty and thereto related information, see

www.axis.com/warranty/

21

E

N

G

L

IS

H

Содержание Q3505-V

Страница 1: ...AXIS Q3505 VE Fixed Dome Network Camera ENGLISH Installation Guide ...

Страница 2: ... SDHC and SDXC are trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Also miniSD microSD miniSDHC microSDHC microSDXC are all trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Regulatory Information Europe This product complies with the applicable CE marking directives and harmonized standards Electromagnetic C...

Страница 3: ...sed of together with household or commercial waste Directive 2012 19 EU on waste electrical and electronic equipment WEEE is applicable in the European Union member states To prevent potential harm to human health and the environment the product must be disposed of in an approved and environmentally safe recycling process For information about your nearest designated collection point contact your ...

Страница 4: ......

Страница 5: ...dicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not avoided could result in damage to property Other Message Levels Important Indicates significant information which is essential for the product to fun...

Страница 6: ... for service matters Transportation NO NO NOTICE TICE TICE When transporting the Axis product use the original packaging or equivalent to prevent damage to the product Battery The Axis product uses a 3 0 V BR CR2032 lithium battery as the power supply for its internal real time clock RTC Under normal conditions this battery will last for a minimum of five years Low battery power affects the operat...

Страница 7: ...er that looks clean to the eye and never polish the surface Excessive cleaning could damage the surface For general cleaning of the dome cover it is recommended to use a non abrasive solvent free neutral soap or detergent mixed with pure water and a soft clean cloth Rinse well with pure lukewarm water Dry with a soft clean cloth to prevent water spotting Never use harsh detergents gasoline benzene...

Страница 8: ...8 ...

Страница 9: ...9 2 Study the hardware overview See page 10 3 Study the specifications See page 13 4 Install the hardware See page 16 5 Access the product See page 19 Package Contents For optional accessories see axis com AXIS Q3505 VE Fixed Dome Network Camera Secure Torx L key I O connector Extra cable gaskets Cable Gasket M20 Cable Gasket M20 3mm Weather shield AXIS Conduit Adapter U Shape 30mm A Installation ...

Страница 10: ...icking Calibrate from the Server Maintenance web page System Options Maintenance 8 9 11 13 19 14 15 16 1 2 3 4 5 6 17 18 7 12 10 20 1 Network connector 2 Control button 3 I O connector 4 Audio out 5 Audio in 6 SD card slot 7 AC DC connector for power accessory 8 Mounting bracket 9 Side lid covering side hole in mounting bracket 10 Conduit adaptor 11 Locking clip 12 Network cable 13 Unit casing 14 ...

Страница 11: ...nds for normal operation after restart Note The Status LED can be configured to flash while an event is active The Status LED can be configured to flash for identifying the unit Go to Setup System Options Maintenance Status LED Behavior and Buzzer Signal for Levelling Assistant For information on the Function button used for levelling the camera see Connectors and Buttons Color Buzzer Camera posit...

Страница 12: ... buttons on the Live View page or by an Action Rule The output will show as active shown under System Options Ports Devices if the alarm device is activated Digital input An alarm input for connecting devices that can toggle between an open and closed circuit for example PIRs door window contacts glass break detectors etc When a signal is received the state changes and the input becomes active sho...

Страница 13: ...is level when the buzzer beeps continuously To view the Status LED Press the button once to light up the Status LEDs Press again to turn them off The LEDs will turn off automatically after 10 seconds Multicable sold separately The multicable can be purchased from an Axis reseller for connecting external equipment to the Axis product The cable provides the following connectors Audio connector See C...

Страница 14: ...ote This pin can only be used as power out 12 V D C Max load 50 mA Digital input Connect to pin 1 to activate or leave floating unconnected to deactivate 0 to max 30 V DC Configurable Input or Output 3 4 Digital output Connected to pin 1 when activated floating unconnected when deactivated If used with an inductive load e g a relay a diode must be connected in parallel with the load for protection...

Страница 15: ...as input 4 I O configured as output Audio Connector 3 5 mm audio connectors stereo 1 2 3 1 Tip 2 Ring 3 Sleeve Audio Input Microphone Line in Balanced Microphone Hot In Unbalance Microphone In Line In Balanced Microphone Cold In Ground Audio Output Line out mono Ground 15 ENGLISH ...

Страница 16: ... required for routing the cable or cables in the wall 2 Route the network cable and the multicable if required through the wall and through the hole or holes in the mounting bracket The cables can be routed along the wall and through the side hole on the mounting bracket To do this detach the locking clip and side lid in the mounting bracket after attaching mounting bracket to wall see Attach Moun...

Страница 17: ... required later Connect the Cables and Attach Unit Casing to Mounting Bracket 1 Insert the SD memory card in the camera unit optional 2 Push the network cable through the black cable gasket in one of the holes in the unit casing using the connector guard provided Pull the network cable back slightly so that the cable gasket adjusts itself on the cable It is recommended to route the cable through t...

Страница 18: ...2 Small lines on optic mount that indicate a pan increment of 3 3 Lines on optic mount that indicate a pan increment of 15 4 Lines on lens cover to help ensure camera is level 1 Pan tilt and rotate the camera to cover the area under surveillance It is possible to pan 360 and tilt to an angle of 90 2 Pan and rotate the lens to adjust image Use the 2 lines on the lens cover to ensure the camera is l...

Страница 19: ...er attach the dome cover to the unit casing by tightening the 4 screws The installation is now complete Access the Product Use the tools provided on the Installation and Management Software CD to assign an IP address set the password and access the video stream This information is also available from the support pages on www axis com techsup Focus Zoom If you have selected Optical zoom for install...

Страница 20: ...nitoring Go to PTZ Preset Positions and follow the online instructions to set the focus In order to be able to retain this focus position after restarting the camera enter a name for this preset in the Current position field and select the Use current position as Home option If you calibrate the optics while in this Optical zoom for monitoring mode select this preset from the Available positions d...

Страница 21: ...ry default settings If no DHCP server is available on the network the default IP address is 192 168 0 90 5 Using the installation and management software tools assign an IP address set the password and access the video stream It is also possible to reset parameters to factory default via the web interface Go to Setup System Options Maintenance Further Information The User Manual is available at ww...

Страница 22: ...Installation Guide Ver M1 14 AXIS Q3505 VE Fixed Dome Network Camera Date April 2014 Axis Communications AB 2014 Part No 54768 ...

Отзывы: