Page 4
AXIS PoE Midspans 8P/16P
Power Cord Requirements
Power cords must meet the requirements for the country they are used in.
• The Midspan must have access to a power outlet. Disconnect the power cord from the outlet, to
eliminate power from the device.
• The flexible cord that connects to the Midspan must have a configuration to connect with an
EN60320/IEC320 inlet connector.
• According to the EN60950/IEC 950 specifications, this device functions under SELV (Safety
Extra Low Voltage) conditions. The conditions are true if the equipment and the connected
device functions under SELV conditions.
• The AXIS PoE Midspans 8P/16P meet the UL/cUL per
EN60950 safety standard. This is displayed in the back side
of the product.
USA and Canada
•
The cord must have a minimum of 10A rated current competence.
•
The cord must be CSA or UL approved.
•
The minimum requirement for the flexible cord is:
• 18 AWG (10A)
• Three-conductor (line, neutral, ground)
• Type SV (Stranded Vacuum Rubber Jacketed) or SJ (Stranded Junior Rubber
Jacketed) or SVT (Stranded Vacuum Rubber Jacketed Themoplastic) or SJT
(Stranded Junior Themoplastic)
• The plug must be earth-grounded with a NEMA 5-15P (15A, 125 V) or
NEMA 6-15P (15A, 250 V) configuration.
Europe and South America
Switzerland
: The supply plug must comply with SEV/ASE 1011.
Denmark
: The supply plug must comply with section 107-2-D1, standard DK2-1a
or DK2-5a.
United Kingdom
: The Midspan is covered by General Approval (section 16.16.060),
NS/G/12345/J100003, for indirect connection to a public telecommunication
system
France and Peru
: IT equipment cannot power this device. In the case of an IT
powered device, the unit needs to be powered by 230 V through an isolation
transformer with a ratio of 1:1 and the secondary connection (Neutral) is properly
grounded.