background image

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

 

 

B SERIES 

 

 

 

 

 

 

 

 

 

 

File: R-B-043-04-09 B42_0 GB 

 

Содержание B Series

Страница 1: ...USER MANUAL B SERIES File R B 043 04 09 B42_0 GB ...

Страница 2: ...General rules 9 10 Balance checking 11 11 Scale adjustment 11 12 Connecting a computer or a printer optional 11 13 Special functions description 14 14 Normal weighing 15 15 Weighing with tare 15 16 Increased readability 15 17 Autozero F AUt 16 18 Funkcja liczenia sztuk F PCS 17 19 Printer cooperation settings F LPt 18 20 Serial port parameters setting F rS 19 21 Constant tare F tAr 20 22 Function ...

Страница 3: ...ed by indicator with additional keys see appendix B Scales have following verification features a seal protecting scale casing against opening notified body stamps and green metrological marking placed on the balance name plate Legal verification is valid for 3 years unless the seal is broken NACE classification 29 24 23 Certificates EC Type Approval Certificate No PL 04 022 Health Quality Certifi...

Страница 4: ...5mm 740mm Power supply 230V 50Hz 8VA Internal feeding option accumulator 6V 12Ah Accumulator working time ok 50 godz Scale weight 13kg 23kg 23kg 21kg 35kg 35kg 35kg EC Verification Scale type B33 B63 B151 B152 B301 Maximum loading 30kg 60kg 150kg 150kg 300kg Minimum loading 200g 400g 1kg 1kg 2kg Reading unit d 10g 5g 1g 20g 10g 5g 2g 50g 10g 50g 10g 100g 10g Verification unit e 10g 20g 50g 50g 100...

Страница 5: ...y B G gross key HR high resolution indicator 0 zero indicator indicator result stabilization indicator indicator NET net weight indicator indication with subtracted tare indicator gross mass after use of B G key indicator indicator of pieces counting indications in pieces LCD option indicator MODE special function setting bar indicator total load indicator graduated 0 100 indicator OFF standby ind...

Страница 6: ...type supplied with the scale Pay attention that supply voltage is compatible with specified technical data Do not use the scale when its cover is opened Do not use the scale in explosive conditions Do not use the scale in high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service 6 Environment protection According to legal r...

Страница 7: ...lows 4 Level the scale with the rotating rear legs so that the air bubble in the water level at the back of the scale is in the middle Lock the legs with the nut 5 Put on the pan 6 Remove everything from a pan and plug a scale to the mains with a ground contact After self tests and result stabilisation the scale displays zero indication 7 In scales with external feeder connect feeder plug to a con...

Страница 8: ..._________________________________________________ 8 Start up Leave the pan empty plug a scale to the mains with a ground contact The scale proceeds with following start up actions Display test Basic electronic components tests C1 C 2 C 6 Program version The scale is now ready to work ...

Страница 9: ...lt 4 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I key The scale reading system is then switched off to standby mode signalled by the indicator OFF in version with the LCD display To switch the scale on press I key The scale is immediately ready to operate maximum accuracy after self tests 5 Weighed sample should be placed in th...

Страница 10: ...ging is more effective when scale is turned off with I key then charging time is about 10 hours It is also possible to connect accumulator directly to PA6V charger leaving accumulator in a scale or take it out if needed In order to take accumulator out take off a pan disconnect accumulator wire and unscrew mounting screws Charging an accumulator through scale feeder 230V feeder scale Charging an a...

Страница 11: ...inter optional The scale is equipped with RS232C or RS485 optional which can be used to connect external devices such as a computer or a printer When cooperating with a printer data is send automatically after result stabilisation but next transmission is possible after removing previously weighted sample The scale sends following information successive number of weighing and weighing result see p...

Страница 12: ...e Byte 10 digit Byte 11 space Byte 12 k l c p or space Byte 13 g b t c or Byte 14 space Byte 15 CR Byte 16 LF scale tarring calling T key press Computer Scale S T CR LF 53h 54h 0Dh 0Ah Scale Computer without response scale turning on off calling I key press Computer Scale S S CR LF 53h 53h 0Dh 0Ah Scale Computer without response scale zeroing calling 0 key press Computer Scale S Z CR LF 53h 5Ah 0D...

Страница 13: ... set low threshold 100kg in scale B150 d 50g the following order should be sent S L 1 0 0 0 0 CR LF 53h 4Ch 31h 30h 30h 2Eh 30h 30h 0Dh 0Ah setting high threshold value Computer Scale S H D1 DN CR LF 53h 48h D1 DN 0Dh 0Ah D1 DN threshold value see Scale Computer without response Note Network number different than zero F rS nr function changes scale working mode communication with a computer is pos...

Страница 14: ...an option on customer request all functions are described in additional brochure when ordered Press MENU key to enter the function menu Functions are displayed successively with consecutive numbers F1 PCS F2 AUt etc To customise the function menu with most frequently used functions use Menu Customisation function ACt When switching between special functions MODE indicator is displayed To make clea...

Страница 15: ... with tare equal to its range To display gross weight press B G key Note Press B G key to return to net weight indication 16 Increased readability Press HR key to display the weighing result for 5s with the highest readability possible This function is especially helpful in scales with legal verification with d e The weighing result with increased readability can be used for informational purposes...

Страница 16: ...AUt When F Aut function is activated the scale automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by pressing T key To leave the function press MENU key then with T key chose F AUt and F 0 Note Autozeroing function is activated automatically for 10 min after switching on 0 01 F AUT F 1 F 0 0 00 T T ...

Страница 17: ...ding unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then with Τ key chose F PCS and F 0 Notes 1 Err 3 communicate signalises that a sample was not put on the pan The same communicate appears if single piece weight is less than one reading unit it is possible to count pieces but measuring error is bigger 2 To chose previously used pi...

Страница 18: ...omatic serial port working mode cooperation with a printer After activation the scale prints a header Weighing result with a successive measurement number is printed automatically after result stabilisation without using key To select computer cooperation mode key activated and weighing results without successive numbers press MENU key then with T key chose F LPt and F 0 0 00 F LPt F 1 F 0 0 00 T ...

Страница 19: ... Odd 0 1 network number when working in multistand computer system when working as a single scale the value should be 0 continuous transmission without using key approx 10 results per second SEnd 0 1 Default parameters underlined To set desired transmission parameters activate F _rS function choose appropriate parameter and press T key to accept needed parameter value The example at the left prese...

Страница 20: ...s empty Tare value may be entered using the keypad or by sampling container weight from the pan Operation sequence The following options are possible F 0 leave the function F 1 activate the function with the previous tare value F 2 sample tare value from the pan F 3 enter tare value with keys 0 T and MENU If the function is active NET indicator is displayed Options F 1 enables to activate the func...

Страница 21: ...ghing with constant tare When tAr function is activated press 0 key to zero the indication and to recall tare value from the memory Tare value is displayed with sign B G key enables for instant switching between net and gross weight Note When the pan is empty T key does not operate to tare the scale use 0 key 1 70 13 70 10 00 0 B G NET ...

Страница 22: ...ct special functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable Operation sequence shown on the picture presents how to add RS232C parameters setting function F rS to the Function Menu To remove a function from the Function Menu choose F 0 in the last operation 0 00 F ACt F 1 F 0 F AUt F rS T T ...

Страница 23: ...To repair the scale please contact our nearest service Error communicates Communicate Possible cause Remedy C 1 6 over 1 min selftests failed if displayed more than 1 minute contact an authorised service the scale was switched on with loaded pan remove a load from the pan mechanical damage of the load cell contact an authorised service L pan missing put the pan on mechanical damage contact an auth...

Страница 24: ...harmonised with the Council Directive 89 336 EEC Additionally scales with the following markings on the name plate a sticker with two digit number of the year in which the mark was affixed and the number of the Notified Body responsible for EC verification a green metrology sticker with M mark a protective seal affixed by the Notified Body comply with requirements stipulated on the EC Type Approva...

Отзывы: