INTRODUCTION

Please read and ensure that that your operation person also reads this

user’s manual carefully before using the appliance. If the appliance is operated
other way than written in this manual, it will not be covered by the warranty.

The manual contains information about installation, usage and maintenance of
our product and should be read carefully. Please ensure that gas connection
to the appliance is installed by qualified personnel according to the local
regulations.

Dear User,

Thank you for purchasing our appliance and for your reliance upon our
company. Our appliances are used in professional kitchens  in 90 countries.
Important: Please read this user’s manual in order to achieve the
desired performance in line with your expectations and to use your
appliance for many years. Please take the warnings mentioned above
into consideration before calling for service.

Please read and ensure that that your operation person also reads this

user’s manual carefully before using the appliance. If the appliance is operated
other way than written in this manual, it will not be covered by the warranty.

The manual contains information about installation, usage and maintenance of
our product and should be read carefully. Please ensure that gas connection
to the appliance is installed by qualified personnel according to the local
regulations.

If you are confused or you don’t have enough information

please get in touch with our authorized service by phone.

Please keep in mind that, if the service technician is delayed

at  your site, related expenses and delay costs will be charged to
you on hourly basis.

3/19

Содержание AX-DPG

Страница 1: ...UAL PRODUCTION YEAR SERIAL NR PUBLISHED ON 07 12 2006 VERSION 06 1 19 GAS TYPE PRESSURE Natural gas Propane gas MVP GROUP CORPORATION 5659 ROYALMOUNT MONTREAL QC CANADA H4P 2P9 Tel 514 737 9701 Fax 51...

Страница 2: ...ONS 6 SAMPLE DATA PLATE AND WARNING NOTICES 7 TRANSPORTING AND MOVING 2 19 8 9 10 INSTALLATION OF THE APPLIANCE 11 SETTING AIR ADJUSTER AND MINIMUM GAS RATE 12 POSSIBLE FAILURES AND WAYS OF ELIMINATIN...

Страница 3: ...performance in line with your expectations and to use your appliance for many years Please take the warnings mentioned above into consideration before calling for service Please read and ensure that...

Страница 4: ...gas 7 WC Propane gas 11 WC 4 19 GAS PRESSURE Natural gas 7 WC Propane gas 11 WC Natural gas 7 WC Propane gas 11 WC BURNER NOZZLES DIAMETER Natural gas 2 25 mm Propane gas 1 45 mm Natural gas 2 25 mm P...

Страница 5: ...MAIN DIMENSIONS AND WARNING NOTICES MODELS AX SPG AX DPG 5 19 HOT SURFACE SAMPLE LABEL Figure 1 Main dimensions...

Страница 6: ...2 Sample data plate 6 19 These appliances shall be installed in conformity with the current regulations and used only in a well ventilated location Consult the instruction before installing and using...

Страница 7: ...ransportation the machine should be moved slowly and the appliances should be fixed on the palette or supported in order to prevent jolt Do not hit or drop the appliance when moving CHANGING THE LOCAT...

Страница 8: ...aterial the distance should be also at least 5 in It is strongly recommended that local fire safety protection instructions are observed INSTALLATION OF THE APPLIANCE All of the gas supply connections...

Страница 9: ...ppearance of bubbles WARNING Never use open flames to detect gas leakages 9 19 GAS PRESSURE CHECKING Measure gas pressure by means of a water type pressure gauge e g a U type pressure gauge with 0 1 m...

Страница 10: ...he device cannot be changed upon customers request Any modifications made on valves and injectors are very dangerous and leaves the appliance out of warranty coverage Any use of non original spare par...

Страница 11: ...LE PART OF THE PRIMARY AIR UNIT AND MINUMUM GAS ADJUSTER FIXED B PLEASE KEEP THIS SETTING DURING OPERATION There are adjustable primary air unit and minimum gas rate srews on every gas value 11 19 Fig...

Страница 12: ...oes not operate 1 Check the pilot burner position 2 In case of thermocouple failure call service 3 Ignition is OK valve is in pilot position the flame goes out 1 The flame control system does not work...

Страница 13: ...baskets and lowered into the tank A GENERAL 1 Pasta cooker is used to cook pasta rice vegetables and very useful for rethermalization OPERATION OF THE APPLIANCE 2 Clean the instrument exterior and the...

Страница 14: ...are is reguired during the process of discharging of the water in pasta cooker figure 6 E 10 Shutting off the pasta cooker If the pasta cooker will not be operated for a period of time turn safety gas...

Страница 15: ...X SPG DPG SERIES A B C OPERATION OF THE APPLIANCE A FRESH WATER INPUT VALVE B FRESH WATER CONTROL KNOB C SAFETY VALVE CONTROL KNOB D FLAME MONITOR PANEL E WATER DISCHARGE CONTROL KNOB 15 19 D E FIGURE...

Страница 16: ...SAFETY GAS VALVE ON MAX POSITION FIGURE 10 SAFETY GAS VALVE ON MIN POSITION FLAME CONTROL SETUP If the pilot flame extinguishes for any reason when the appliances is on the system will close itself do...

Страница 17: ...and openings should be clean and not clogged 4 The parts dismantled during clean up should be installed back by the technical service personnel and after the installation gas leakage must be checked C...

Страница 18: ...ear the appliance Do not clean up the appliance with pressurized water This appliance is designed for industrial use and should only be operated by trained person according to this manual 18 19 The ap...

Страница 19: ...T OF ITS EQUIPMENT The manufacturer reserves the rights to alter design and specifications without notice 19 19 MVP Group Corporation MVP hereby warrants all new equipment bearing the name AXIS and in...

Страница 20: ......