
1. To check relay and tampering state, go to:
Setup > System Options > Ports & Devices > I/O ports
2. Make sure the following values are configured for
IO1
.
Input
TamperSwitch
Tampering
IO1
Name
Port Type
I/O
Usage
Normal state is... Current Status
Open circuit
Open circuit
Relay
Door
Door
RELAY
Name
Port Type
I/O
Usage
Normal state is...
Current Status
Open circuit
Open circuit
Open circuit
Closed circuit
3. Depending on your lock type, configure the following values for
RELAY
,
and click
Save
.
Open circuit
for a fail-secure lock
Closed circuit
for a fail-safe lock
4. Go to:
Setup > Events > Action Rules
5. Modify “TAMPERING: Tilt detected” to the following values and click
OK
.
Configure relay and tampering state in AXIS A8105-E
built-in web pages
Start condition only
Trigger:
Input Signal
Digital Input Port
TamperSwitch (Port2)
Active:
Yes
No
Recommended setup using
AXIS TA8501 Physical Tampering Switch
Page 2/2