AXIS 30 W Midspan AC/DC
Troubleshooting Guide
Страница 1: ...AXIS 30 W Midspan AC DC Troubleshooting Guide ...
Страница 2: ...d the midspan to disconnect from the device Remove and plug the power cord into the midspan again to resolve the problem Green Flashing No load Green Solid Power on Green and red Flashing alternately between red slowly and green quickly The PoE over current protection OCP or the short circuit protection SCP has been triggered Red failure Green retrial Green and red Flashing alternately between red...
Страница 3: ...an external power splitter is in use verify that it works Verify that there is no short over on any of the twisted pair cables or over the RJ45 connectors If possible reconnect the same powered device into a different midspan The end device operates but there is no data link Verify that the port on the front panel is continuously lit Verify that a standard Category 5e 6 straight wired cable with f...
Страница 4: ...Troubleshooting Guide Ver M1 7 Date May 2021 Axis Communications AB 2021 Part No t10164630 ...