Axis 290A Скачать руководство пользователя страница 7

 

290A Installation Instructions

Completing the installation

Caution:

 The heater at the front of the housing unit becomes hot when in operation. If applicable, position 

the cable connected from the DC IRIS socket to the lens so that it does not touch the heater.

• Ensure that all cables and connections are correctly and safely installed.
• Ensure that the lens setting is correct and make final adjustments if required 

 

(refer to Axis Installation Guide).

• Ensure that the window is clean. Wipe it with a dry cloth if it is not. Do not use a 

damp or wet cloth! Ensure that no tools/loose parts are left in housing.

• Finally ensure that all the visible seals are undamaged and in position.

Warning:

 If any of the seals are damaged or missing , the housing will not be weatherproof and water 

ingress may occur. This can seriously damage to the camera and other system equipment. Installations that 
have been completed with damaged or missing seals are not covered by any warranty.

Once you have checked all the above items, close the housing with the two clips on the 

side:

1. Loosen the positioning bolt (13) 

sufficiently to move the housing 

in the desired position. Use the 

large allen key (1) to do this. Once 

the housing is in its final position 

firmly lock up the positioning 

bolt (13). 

Caution:

 Do not over-tighten or use exces-

sive force. You may damage the 
bracket-swivel assembly if you do so.

2. Finally, securely lock the housing at the front and rear using the locking screws.

The installation is now complete.

Locking screw 

at front

Содержание 290A

Страница 1: ...lid walls Fitting the camera inside the housing Recommendation Fit the camera in indoor conditions to prevent the build up of dust and moisture inside the housing 1 Open the housing by releasing the two clips on the side 2 Undo the two screws 6 on the camera mounting board 7 Slide the board backwards and lift it out 3 Refer to the Axis Installation Guide provided with the Axis camera for instructi...

Страница 2: ...connected from the DC IRIS socket to the lens so that it does not touch the heater Caution Do not over tighten the screw as you may damage the camera 6 Position the camera with the board inside the housing as before Make sure the board is inserted under the lugs beneath the window in its most forward position Use the two screws 6 to secure the board with the camera and lens in the housing Routing ...

Страница 3: ...the bracket arm 12 The positioning bolt 13 is held in the bracket arm 12 by a plastic washer inside 2 Detach the swivel 11 from the housing by loosening its four screws Use the small allen key 2 to do this The four screws are held in the swivel 11 by plastic washers 3 Position the bracket arm 12 on the wall in the position required and drill four fixing indicators Remove the bracket arm and drill ...

Страница 4: ...ace of the swivel 11 by pushing the power cable through the off centre hole on the left and the network cable through the off centre hole on the right The two off centre holes should be positioned towards the back 9 Position the housing 8 on the swivel 11 with the white rubber seal 9 in between the network cable going through the larger hole in the black board and the power cable going through the...

Страница 5: ...rts of the system may require a bigger conductor area You are responsible that the requirements of these regulations are met 3 Route the power cable through the cable tie 14 Wire into the fused terminal block 15 as follows Blue neutral N Brown live L Green yellow earth Refer to the wiring diagram below Wiring diagram 290A Caution Ensure that all wires are correctly and securely wired into the term...

Страница 6: ...ing from the 12V DC power supply with the 4 pin green terminal block supplied with the camera AXIS 211A Network Power 4 pin terminal block Black white wire wire Black AXIS 221 223M replace the 4 pin green power connector coming from the 12VDC power supply with the 3 pin green terminal block supplied with the camera and connect the wires Power Network 3 pin terminal block Black Black white wire wir...

Страница 7: ...maged and in position Warning If any of the seals are damaged or missing the housing will not be weatherproof and water ingress may occur This can seriously damage to the camera and other system equipment Installations that have been completed with damaged or missing seals are not covered by any warranty Once you have checked all the above items close the housing with the two clips on the side 1 L...

Страница 8: ...ish The window should only be cleaned with a dry cloth Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the camera Use a 5A 250 VAC fuse and ensure that the mains is disconnected before beginning Specifications Weatherproof to IP66 CE Power requirement 100 240V AC 60 50Hz Operating temperature 20 C to 42 C 4F to 108F Approximate weight 3 2 kg 7 1 lbs Color R...

Отзывы: