Table 1 - I/O terminal connector block
Table 2 - LED indicators
Pin Function
Description
1
Output A
On the external device output terminals (A and B), there is no distinc-
tion between positive and negative (+ and -). The terminals use a pho-
tocoupler and are electrically isolated from the other internal
circuitry.
The maximum load should not exceed 100mA and the maximum volt-
age should be not more than 50VDC or 35VAC.
2
Output B
3
Digital Input 1
Connect to GND to activate, or leave floating (or unconnected) to
deactivate.
4
Digital Input 2
5
RS-485/422-A
(non-inverting)
A half-duplex RS-485/422 interface for controlling auxiliary equip-
ment.
6
RS-485/422-B
(inverting)
7
GND
Ground.
LED Function Color
Description
1
Network
Green
Steady for connection to 100 Mbit/s network. Flashes for network
activity.
Amber
Steady for connection to 10 Mbit/s network. Flashes for network activ-
ity.
Red
Flashes rapid red, together with the Status indicator, for hardware
error.
Unlit
No connection.
2
Status
Green
Shows steady green for normal operation.
Amber
Shows steady amber during reset to factory default or when restoring
settings.
Red
Slow flash for failed upgrade. Rapid flash, together with the Network
indicator, for hardware error.
3
Heater
Green
Steady green when the power connected is sufficient for the heater
i.e. (12V DC min 20W or 24V AC min 25VA)
Red
Insufficient power for the heater.
4
Power
Green
Normal operation.
Amber
Flashes green/amber during firmware upgrade.