AXIS 200+
Users Manual
Section 5: Using the AXIS 200+
55
Example 2
Activate on Input port 1 low and Input port 2 transition from low
to high.
Triggering Fields
Summary
This table summarizes the valid values of the triggering event fields:
Commands
Several CRON script commands can be used within an entry. All
commands must be terminated with a semi-colon ;.
This table lists the available commands:
Notes:
❏
Refer to the
Appendix G - CRON Script Command Reference
description of the syntax of the commands.
0I1&/I2
Time and Date Fields
Input and Boot
Field
(Optional)
Field #
1
2
3
4
5
6
Description
Minute
Hour
Day
Month
Day of the Week Conditional Tag
Valid values
*
0-59
*
0-23
*
1-31
*
1-12
*
0-6
0 = Sunday
BOOT
B
I1, I2
Command
Description
alert
Sends a message to a remote host.
buffer_init
Initiates an image buffer.
buffer_start
Stores snapshots in the image buffer.
buffer_stop
Ends the storing of snapshots in the image buffer.
ftp
Transfers an image to a remote host using FTP.
Sends an e-mail using the Simple Mail Transfer Protocol (SMTP).
offline
Terminates the current PPP connection.
online
Dials up a modem for PPP connection.
reset
Resets the software or hardware of the unit.
sleep
Makes a pause in the CRON script execution.
snapshot
Updates the last snapshot image.
Содержание 200+
Страница 1: ......
Страница 2: ...AXIS 200 User s Manual AXIS 200 Network Camera Server User s Manual ...
Страница 31: ...Section 3 Assigning an IP Address AXIS 200 User s Manual 30 ...
Страница 43: ...Section 4 Configuring the AXIS 200 AXIS 200 User s Manual 42 ...
Страница 75: ...Appendix B The Parameter List AXIS 200 User s Manual 74 ...
Страница 79: ...Section 6 Updating the Software AXIS 200 User s Manual 78 ...
Страница 83: ...Appendix C Technical Specifications AXIS 200 User s Manual 82 Dimensions ...
Страница 89: ...Appendix D The Auxiliary IO Port AXIS 200 User s Manual 88 ...
Страница 99: ...Appendix E The RS232 Serial Port AXIS 200 User s Manual 98 ...