The STIM-PRO I-2000 is a medical device. The primary  
purpose is to stimulate muscles and nerves of the human 
body electrically through skin (transcutaneous) and  
mucous membranes (transmucosal) in order to strengthen 
the immune system and to alleviate incontinence problems.

What is incontinence?

Incontinence is defined as the involuntary loss of urine, 
faeces or both. 

Causes and forms of incontinence

Stress incontinence - 

This is the most common type of 

incontinence that usually affects women. At first, it only  
occurs during physical exertion and then later at rest,  
causing a drop-wise or radiant loss of urine. Often the pelvic 
floor muscles relax. This results in a lowering of the organs 
of the small pelvis. The resulting increased internal  
abdominal pressure can no longer reach the urethra as a 
closing pressure, but it can still reach the bladder at full 
strength. 
 
Stress incontinence is divided into three degrees of severity:

Involuntary urination

1st degree: 

in case of sudden, heavy stress, e. g. coughing, 

laughing or sneezing

2nd degree:

 for light physical strain, e. g. when walking, 

climbing stairs or lifting things

3rd degree:

 in the case of unstressed movements, standing 

or lastly lying down

 

INTRODUCTION

2

AXION

EN

Содержание STIM-PRO I-2000

Страница 1: ...INSTRUCTION MANUAL STIM PRO I 2000 axion GmbH Mollenbachstr 13 71229 Leonberg Germany 2460 ...

Страница 2: ...occurs during physical exertion and then later at rest causing a drop wise or radiant loss of urine Often the pelvic floor muscles relax This results in a lowering of the organs of the small pelvis The resulting increased internal abdominal pressure can no longer reach the urethra as a closing pressure but it can still reach the bladder at full strength Stress incontinence is divided into three de...

Страница 3: ...rigger can also be an age related muscle decline Anal incontinence is also classified into 3 severity levels Involuntary loss of 1st degree flatulence 2nd degree flatulence and or liquid faeces 3rd degree solid faeces The treatment of incontinence with stimulation current Stimulation current therapy is suitable for the treatment of stress incontinence overactive bladder or urge incontinence as wel...

Страница 4: ...e carotid arteries Do not place electrodes on the front of the throat Be careful with stimulation over metal implants Do not place electrodes above your heart Do not use electrodes on open wounds injuries Do not use if you have fever Do not use if you have arrhythmia Do not use if you have epilepsy Never use the device when you are operating machines Never use near explosive or flammable gases Alw...

Страница 5: ...rvical cancer fistulas fistulas or the inversion of uterus vagina The device must not be used in case of infections in the vaginal or rectal area For hygiene reasons the probe may only be used by one person The unit must not be used if the pelvic floor is completely denervated Each STIM PRO I 2000 is fully equipped with the following standard equipment 1 piece EMS pelvic floor trainer 1 piece Elec...

Страница 6: ...ses Insert the probe slowly and gently into the vagina or anus Against stress incontinence women can use both a vaginal and a rectal probe A vaginal probe is recommended for the treatment of overactive bladder and urge incontinence a with a probe Applying a vaginal probe Applying a rectal probe The pelvic floor can be stimulated with either a rectal or vaginal probe or with externally attached sel...

Страница 7: ...ching the electrodes Place the electrode with the red connecting cable above the pubic bone Place the electrode with the black connection cable either above the buttocks see fig 1 2 or alternatively on the perineum see fig 3 b with self adhesive TENS machine pads Fig 1 Electrode placing for women Fig 2 Electrode placing for men Fig 3 Alternative perineal placing for both men and women 7 STIM PRO I...

Страница 8: ... Turn on the device Press and hold the On Off button for a long time to turn the device on During the application you can pause and restart the application by briefly pressing this key Program selection start of stimulation In program mode you can choose between 5 different programs These are fully programmed just set the current intensity and start the treatment The program starts immediately whe...

Страница 9: ...wer button Remove the adhesive electrodes and stick them back on the protective foil then remove the connection cables If you are using a probe slowly pull it out of the vagina or anus Attention To avoid cable breakage the probe must always be pulled out at the shaft Clean the probe with warm water and soap rinse and store in a dry plastic bag Key lock The control elements are locked by pressing t...

Страница 10: ...Front CONSTRUCTION OF THE DEVICE Back 10 AXION EN ...

Страница 11: ...e low battery indicator is shown Make sure the power is off Open the battery compartment on the back of the device Remove the batteries Insert the new batteries Please check that the polarity is correct Close the battery compartment CHANGING BATTERIES 11 STIM PRO I 2000 EN ...

Страница 12: ...e put it back into the carrying box and keep it in a cool dry place The packed TENS device should be stored and transported under the temperature range of 20 C 60 C relative humidity 20 95 atmosphere pressure 500 hPa 1060 hPa A For safety reasons review the following checklist once a week Check the device for deformation of the housing or damage to defective output sockets Make sure that the descr...

Страница 13: ...imulation current Check if the electrodes are connected to the same channel correctly and if the intensity is high enough The STIM PRO I 2000 device is in compliance with the EN 60601 1 2 2007 and 60601 1 2006 safety standards The device must be subjected to safety checks and maintenance by authorized technicians before use and each re use but at least every 24 months Please consult your distribut...

Страница 14: ... 9cm H 07 Weight 123 g 08 Frequency Pre set ranging from 1 100 Hz 09 Pulse width Pre set possible values 150μs 200μs 250μs 10 Modes 5 pre defined programmes P1 P5 11 Low battery indicator Is shown when the batteries are empty Replace batteries immediately 12 Operating conditions Temperature 0 C to 40 C Relative humiditiy 30 75 Air pressure 700 hPa 1060 hPa 13 Note All technical values include a to...

Страница 15: ...ing the failure to follow the operating instructions loss or dropping Manufacturer axion GmbH Mollenbachstr 13 71229 Leonberg Germany www tens ems com en 1 Advice for operation 2 Degree of electrical protection 3 Donotinserttheplugintothepowersupplysocketof230V 4 Timer 5 Low battery indicator 6 Increament 7 Decreament 8 Read the instruction manual 9 Direct current DC 10 Manufacturer 11 Serial numb...

Отзывы: