3.2.5 COM2 Data/Power Selection (JP11)
The COM2 port has +5V level power capability on DCD and +12V level on RI by
setting this jumper. When this port is set to +5V or +12V level, please make sure its
communication mode is RS-232. You can change the communication mode (RS-
232/422/485) via BIOS setting.
Function
Setting
Power: Set COM2 pin 1 to +5V level
1-3 close
Data: Set COM2 pin 1 to DCD (Default)
3-5 close
Power: Set COM2 pin 8 to +12V level
2-4 close
Data: Set COM2 pin 8 to RI (Default)
4-6 close
3.2.6 COM1 Data/Power Selection (JP12)
The COM1 port has +5V level power capability on DCD and +12V level on RI by
setting this jumper. When this port is set to +5V or +12V level, please make sure its
communication mode is RS-232. You can change the communication mode (RS-
232/422/485) via BIOS setting.
Function
Setting
Power: Set COM1 pin 1 to +5V level
1-3 close
Data: Set COM1 pin 1 to DCD (Default)
3-5 close
Power: Set COM1 pin 9 to +12V level
2-4 close
Data: Set COM1 pin 9 to RI (Default)
4-6 close
Содержание eBOX620-841-FL Series
Страница 1: ...eBOX620 841 FL Series Embedded System User s Manual...
Страница 13: ...eBOX620 841 FL Series User s Manual Introduction 5 1 3 2 Wall mount Bracket Dimension...
Страница 15: ...eBOX620 841 FL Series User s Manual Introduction 7 Rear View Rear View drawing...
Страница 30: ...eBOX620 841 FL Series User s Manual Hardware Installation 22 This page is intentionally left blank...
Страница 46: ...eBOX620 841 FL Series User s Manual Jumper Setting Connector 38 This page is intentionally left blank...
Страница 61: ...eBOX620 841 FL Series User s Manual BIOS Setup Utility 53 North Bridge...