2
©
Copyright 2020 Axiomtek Co., Ltd.
Version A2 July 2020
Printed in Taiwan
Bottom View
Switch Settings
Before applying power to the CEM520, please make sure onboard
switches are in factory default positions.
Switch
Description
Setting
SW1
Auto Power On
Default: Disable
SW1-1 OFF
Restore BIOS Optimal Defaults
Default: Normal Operation
SW1-2 OFF
SW2
PCI-Express Bifurcation Setting
Default: One x16 PCI-Express
SW1-1 OFF,
SW1-2 OFF
Connector
Connector
Description
CN1
Fan Connector
BAT1
Battery Connector
SS1
COM Express
TM
Connector
SS2
COM Express
TM
Connector
DIMM1
Channel 0 DDR4 SO-DIMM Socket
DIMM2
Channel 1 DDR4 SO-DIMM Socket
©
Copyright 2020 Axiomtek Co., Ltd.
3
Version A2 July 2020
Printed in Taiwan
Installing Thermal Solution
For thermal dissipation, a thermal solution enables the CEM520’s
components to dissipate heat efficiently. All heat generating components
are thermally conducted to the heatsink in order to avoid hot spots. Figure
below illustrates how to install the thermal solution on CEM520.
1. There is a protective plastic covering on the thermal pads. This must
be removed before the heatsink can be mounted.
2. Each heatsink is designed for a specific CEM module. The thermal
pads on the heatsink are designed to make contact with the necessary
components on the CEM module. When mounting the heatsink you
must make sure that the thermal pads on the heatsink make complete
contact (no space between thermal pad and component) with the
corresponding components on the CEM module. This is especially
critical for CEM modules that have higher CPU speeds (for example
1.0GHz or more) to ensure that the heatsink acts as a proper thermal
interface for cooling solutions.
3. Before installing the heatsink to the CPU module, please apply thermal
grease on the CPU die. This CPU module has assembly holes for
installing heatsink plate. Use the appropriate screws to secure the
heatsink plate to the CEM520. Be careful not to over-tighten the screws.