background image

2      9418E880000E 

©

Copyright 2016 Axiomtek Co., Ltd. 

Version A1 March 2016 

Printed in Taiwan 

Jumper Settings

 

Before applying power to the CAPA880, please make sure all of the 
jumpers are in factory default positions. 
 

Jumper 

Description 

Setting 

JP1 

LVDS +3.3V/+5V/+12V Voltage Selection 
Default: +3.3V 

5-6 Close 

CN6 Pin 1: DCD

3-5 Close 

JP2 

COM1 Data/Power Selection 
Default: RS-232 Data 

CN6 Pin 8: RI 

4-6 Close 

JP3 

Restore BIOS Optimal Defaults 
Default: Normal Operation 

1-2 Close 

JP5 

Auto Power On 
Default: Disable 

1-2 Close 

 

Note:   Please refer to the CAPA880 series product information CD for the 

complete user’s manual, drivers and utilities. User’s manual and related 
documents are in Acrobat PDF format.
 

 

Board Layout 

 

Top View 

 
 

9418E880000E      3 

©

Copyright 2016 Axiomtek Co., Ltd. 

Version A1 March 2016 
Printed in Taiwan 

 

 

Bottom View 

 
 
 
 
 
 
 
 
 
 
 

 
 

 

Side View 

 