Jumper and Switch Settings

 

Before  applying  power  to  the  CAPA312,  please  make  sure  all  of  the 
jumpers and switch are in factory default positions. 
 

Jumper/Switc

Description 

Setting 

JP3 

Restore BIOS Optimal Defaults 
Default: Normal Operation 

1-2 Close 

JP4 

COM3 Data/Power Selection 
Default: RS-232 Data 

CN4 Pin 1: DCD 

3-5 Close 

CN4 Pin 8: RI 

4-6 Close 

JP5 

LVDS and eDP +3.3V/+5V/+12V Voltage 
Selection 
Default: +3.3V 

1-2 Close 

SSW1 

Auto Power On 
Default: Disable  

1-2 Close 

 

Note:   Please contact your local vendors if any damaged or missing items. DO 

NOT apply power to the board if there is any damaged component. 

 

Board Layout 

 