1. Introduction

This unit is a non-contact AC voltage detector for detecting 5-1000V ac voltage. When it detects ac voltage,
the detection indicator LED will flash red and the built-in buzzer will sound short beep(s). In addition,
illumination function is also provided. If the batteries are high enough, the detection indicator LED will
flash red periodically as a high battery indication.

2. Features

1. Safe, reliable non-contact AC voltage detection.
2. You can use this unit to check whether a cable, wire or socket contains ac voltage, or use it to locate
breakpoint on a live line.
3. Adjustable detection sensivity.
4. After adjusting the unit’s detection sensivity to a suitable level, you can use this unit to discriminate
between Live terminal and Neutral terminal on a energized AC110V power socket.
5. Illumination function.
6. Low battery indication.

3. Specification

- Operating Environment: temperature: 0°C - 40°C; relative humidity: <85%; indoor use
- Voltage Detecting Range: 5V AC - 1000V AC
- Frequency Range: 50Hz - 400Hz
- Safety Category: CAT IV 1000V
- Battery: 1.5V battery, AAA or equivalent, 2 pieces
- Size: 154x32x28mm
- Weight: about 50g (including battery)

Содержание AX-T03

Страница 1: ...n use this unit to check whether a cable wire or socket contains ac voltage or use it to locate breakpoint on a live line 3 Adjustable detection sensivity 4 After adjusting the unit s detection sensiv...

Страница 2: ...you just turn on the unit by turning this power switch sensivity knob forwards a little the unit will sound a click Now the unit is at the highest detection sensivity level Continuing to turn this kno...

Страница 3: ...s sensivity to the highest level and if you want to locate a breakpoint on a live line you should lower the unit s sensivity appropriately 3 Decrease the unit s sensivity then insert the unit s probe...

Страница 4: ...or 3 phase wires separate them far enough apart from each other and perform voltage detection on each line 3 Because the unit s detection limit sensivity setting and the detection distance can affect...

Страница 5: ...y loss 3 The contents of this Instructions Sheet can not be used as the reason to use the unit for any special application 10 Disposal of this article Dear Customer If you at some point intend to disp...

Страница 6: ...a do sprawdzania czy w kablu przewodzie lub gnie dzie obecne jest napi cie AC lub do wykrywania przerw w instalacji pod napi ciem 3 Regulowana czu o wykrywania 4 Po wyregulowaniu czu o ci wykrywania u...

Страница 7: ...przez delikatne obr cenie w cznika zasilania regulatora czu o ci do przodu urz dzenie wyda d wi k W tym momencie urz dzenie b dzie znajdowa si na najwy szym poziomie czu o ci wykrywania Dalsze obracan...

Страница 8: ...ania 2 Przy sond urz dzenia w pobli e przewodu lub gniazda kt re chcesz sprawdzi W przypadku gdy urz dzenie wykryje napi cie AC wbudowany brz czyk zacznie wydawa d wi k i dioda LED wykrywania zacznie...

Страница 9: ...yw pojemnika na baterie i wymie stare baterie na dwie nowe baterie tego samego typu bateria 1 5V AAA lub odpowiednik upewniaj c si e biegunowo jest prawid owa Zamontuj ponownie pokryw pojemnika na bat...

Страница 10: ...pracy z urz dzeniem Zgodno z dyrektywami Unii Europejskiej 9 Deklaracja 1 Instrukcja obs ugi mo e ulec zmianie bez powiadomienia 2 Nasza firma nie ponosi adnej odpowiedzialno ci za jakiekolwiek strat...

Отзывы: