1.4.2 Relative humidity:  

 

 

less than 90% 

1.5 Size:   

 

 

 

360mm×265mm×165mm 

1.6 Operating time:   

 

 

8 hours continuously 

 
2. OPERATION 
2.1 Controls and description of front-panel 
 
(1) Meter or LED: indicates master output voltage and current value. 
(4) Meter or LED: indicates slave output voltage and current value. 
(5) Slave constant voltage adjustment: adjust slave output voltage value. 
(6)  Slave  constant  current  adjustment:  adjust  slave  output  current  value  (adjust  the  current-limiting 
protection point). 
(7) Power switch: It is set to “ON” state(the switch is pressed in), the unit is switched on, at this time, 
the  constant  voltage  (C.V.)  or  constant  current  (C.C.) 

indicator  is  on,  otherwise,  the  unit  is  in  “OFF” 

state (the switch is sprung out). 
(8)  Slave  constant  current  state  or  two-way  parallel  state  indicator:  When  slave  output  is  in  constant 
current state or the two adjustable is in parallel, this indicator is on. 
(9) Slave constant voltage indicator: When slave output is in constant voltage state, this indicator is on. 
(10) Slave output negative binding post: Negative polarity  of output voltage is connected to negative 
terminal of load. 
(11) Case grounded terminal: The case is connected to the earth. 
(12)  Slave  output  positive  binding  post:  positive  polarity  of  output  voltage  is  connected  to  positive 
terminal of load. 
(13/14) The control switch for selecting the two adjustable outputs independent, series or parallel. 
(15) Master output negative binding post: Negative polarity of output voltage is connected to negative 
terminal of load. 
(16) Case grounded terminal: The case is connected to the earth. 
(17)  Master  output  positive  binding  post:  Positive  polarity  of  output  voltage  is  connected  to  positive 
terminal of load. 
(18)  Master  output  constant  current  state  indicator:  When  master  output  is  in  constant  current  state, 
this indicator is on. 
(19) Master output constant voltage state indicator: When master output power is in constant voltage 
state, this indicator is on. 
(20)  Fixed  5V  DC  output  negative  binding  post:  Negative  polarity  of  output  voltage  is  connected  to 
negative terminal of load. 
(21)  Fixed  5V  DC  output  positive  binding  post:  Positive  polarity  of  output  voltage  is  connected  to 
positive terminal of load. 
(22)  Master  output  constant  current  adjustment: Adjust  master  output  current  value.  (Adjust  current-
limiting protection point) 
(23) Master output constant voltage adjustment: Adjust master output voltage value. 
 
 