Axioma QALCOSONIC F2 Скачать руководство пользователя страница 4

PEF2V02 

 

                2017-11-20 

 
 
 

Type number combination of the ultrasonic flow sensor

 

 

                    
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 
 

 
 
                         

 

 

 

 

 

Remark: 
                                  * - marked numbers are used for order numbering only 

 

Type 

  Technical data of the flow sensor: 

Permanent  

flow-rate, m

3

/h 

Overall length, 

mm 

End connections 

Code 

0,6 

110 

G  ¾ 

1,0 

110 

G ¾ 

1,5 

110 

G ¾ 

1,5 

165 

G ¾ 

1,5 

130 

G1 

2,5 

130 

G1 

3,5 

260 

G1 ¼ 

6,0 

260 

G1 ¼ 

10,0 

300 

G2 

10,0 

300 

DN40 

15,0 

270 

DN50 

3,5 

260 

DN25 

6,0 

260 

DN25 

0,6 

190 

G1

 

1,0 

190 

G1

 

1,5 

190 

G1

 

2,5 

190 

G1

 

0,6 

190 

DN20 

1,0 

190 

DN20 

1,5 

190 

DN20 

2,5 

190 

DN20 

3,5 

260 

DN32 

6,0 

260 

DN32 

25 

300 

DN65 

40 

350 

DN80 

40 

300 

DN80 

60 

350 

DN100 

60 

360 

DN100 

 

  Ratio of flow-rate limits (q

p

/q

i

): 

Code 

100  

 250  
(with the exeptions of sensors q

p

=

0,6 m

3

/h; 1,0 m

3

/h; 3,5 m

3

/h)  

 
 
 
 
 

   

Length of the connection cable  between measuring section and electronic unit: 

Cable length 

Code 

1,2 m  

2,5 m  

5 m 

 

                     

QALCOSONIC    F2

–   

1

  

1

  

–NM - 1  - 0* 

Pulse value of the flow sensor 

M

N

10

 m

3

/pulse* 

* - where N- possible number 1...9, M 

– possible number 1...6.

 

 

Power supply: 

Code 

Internal battery 3,6 V 

External  24 V AC/DC  

 

Length of the pulse output device  connection cable, m:   
    3; 5; 10; 15... 200,    0 (or omitted) - none 

 
 
 
 

Содержание QALCOSONIC F2

Страница 1: ...Axioma LEZ UAB ULTRASONIC FLOW SENSOR QALCOSONIC F2 TECHNICAL DESCRIPTION INSTALLATION AND USER INSTRUCTIONS PEF2V02 KAUNAS...

Страница 2: ...classified as waste electronic equipment in terms of the European Directive 2012 19 EU WEEE Marking of electrical and electronic equipment in accordance with Article 14 2 of Directive 2012 19 EU This...

Страница 3: ...aution If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 1 APPLICATION FIELD Ultrasonic flow sensor QALCOSONIC F2 is desi...

Страница 4: ...0 6 190 DN20 G 1 0 190 DN20 H 1 5 190 DN20 K 2 5 190 DN20 L 3 5 260 DN32 O 6 0 260 DN32 P 25 300 DN65 R 40 350 DN80 S 40 300 DN80 U 60 350 DN100 T 60 360 DN100 V Ratio of flow rate limits qp qi Code 1...

Страница 5: ...9 8 G1 2 5 5 0 0 025 0 005 190 9 4 G1 DN20 3 5 7 0 0 035 0 017 260 4 G1 1 4 DN25 DN32 6 0 12 0 0 024 0 012 260 10 G1 1 4 DN25 DN32 6 0 12 0 0 06 0 012 260 10 G1 1 4 DN25 DN32 10 0 20 0 0 04 0 02 300 1...

Страница 6: ...al power supply 12 V 42 V DC or 12 V 36 V 50 60 Hz AC 10 mA max internal backup battery size AA 3 6 V 2 4 Ah lithium battery Li SOCl2 service life not less than 12 years without data reading via a dig...

Страница 7: ...The following measuring section sealing is provided Manufacturer s adhesive seal sticker on the screws of protective cover of flow sensor see Annex C fig C2a b c d e Manufacturer s hanged seals on ult...

Страница 8: ...pulse cable is already installed Customer pulse cable Connection of the customer pulse cable It is recommended to use copper wire cable with the cross section 0 2 0 5 mm2 By means of tweezers remove...

Страница 9: ...on in normal working mode pipeline must be under pressure and fully filled with heat conveying liquid The location and position of the flow sensor must be selected in such a way as to reduce the risk...

Страница 10: ...in Figure 7 2 Fig 7 2 Test mode activation For working in this mode the calculator cannot be closed When the jumper J is set output pulses are formed Ending of verification mode Remove jumper J to le...

Страница 11: ...PEF2V02 2017 11 20 11 Annex A Electrical wiring diagrams of flow sensor QALCOSONIC F2 Fig A1 Electrical wiring diagram...

Страница 12: ...to the external power supply Table A1 Numbering of terminals Terminal No Destination 18 Output pulses of volume 19 GND Numbering of external power supply module terminals Terminal No Destination 54 24...

Страница 13: ...sensor Fig B2 Sizes and dimensions of the flow sensor Fig B2 1 Threaded end connections G3 4 Fig B2 2 Threaded end connections G1 Mounting length L 110 mm or L 165 mm mounting length L 130 mm a b Fig...

Страница 14: ...PEF2V02 2017 11 20 14 Annex B a Threaded end connections G1 1 4 b Flanged end connection DN25...

Страница 15: ...PEF2V02 2017 11 20 15 Annex B c Flanged end connection DN32 Fig B2 4 Threaded end connections G1 1 4 a Flanged end connection DN25 b Flanged end connection DN32 c mounting length L 260 mm a b...

Страница 16: ...PEF2V02 2017 11 20 16 c Fig B2 5 Threaded end connections G2 a flanged end connection DN40 b c two design options Mounting length L 300 mm...

Страница 17: ...Brass housing DN65 PN16 DN65 PN25 DN80 DN100 L 300 300 350 350 D 185 185 200 220 H 185 185 200 220 D1 145 145 160 180 B 200 200 215 235 D2 18 18 18 18 n 4 8 8 8 b Dimensions of flow sensors DN65 DN80...

Страница 18: ...e sticker 2 manufacturer warranty seal adhesive sticker 3 mounting seal a Flow sensor G 3 4 b Flow sensor G 1 or DN20 1 1 1 1 c Flow sensor G 1 DN25 or DN32 d Flow sensor G 2 or DN40 1 1 1 1 e Flow se...

Страница 19: ...ed in the paragraph 2 of this document if transportation storage and operation conditions will be followed Warranty period 12 months from bringing into operation but not more than 18 months from manuf...

Отзывы: