background image

POWER INPUT

MAINS IN - 

Powercon® NAC3FCA power input connector (blue). To switch the ampli

fi

 er on, insert the 

Powercon® connector and turn it clockwise into the ON posi  on. To switch the ampli

fi

 er o

 , pull back 

the switch on the connector and turn it counter-clockwise into the POWER OFF posi  on.

WARNING!

 

In the case of product failure or fuse replacement, disconnect the unit completely 

from the mains power. The power cable must only be connected to a socket corresponding 
to the speci

fi

 ca

Ɵ

 ons indicated on the ampli

fi

 er unit. The power supply must be protected by 

a suitably rated thermo-magne

Ɵ

 c breaker.

 

Preferably use a suitable switch to power on the 

whole audio system leaving the Powercon® always connected to each speaker, this simple trick 
extend the life of the Powercon® connectors.

CONTROL PANEL

ON - 

This LED indicates power on status.

PROT - 

This red LED lights when the amplifier 

module is in protect mode for an internal fault and, 
consequently, the ampli

fi

 er is muted.

SIGN LIMIT - 

This LED lights in green to indicate the 

presence of the signal and lights in red when an 
internal limiter reduces the input level.

INPUT -

 Audio signal input with locking XLR connector. 

It has a fully electronically balanced circuitry including 
AD conversion for the best S/N ratio and input 
headroom.

LINK -

 A direct connec  on from the input connector to 

link other speakers with same audio signal.

GND LIFT -

 This switch li   the ground of the balanced 

audio inputs from the earth-ground of the ampli

fi

 er 

module.

PRESET BUTTON - 

This bu  on has two func  on:

1)

 Pressing it while powering on the unit:

ID ASSIGN

 

the internal DSP assigns a new ID to the unit for the PRONET remote control opera  on. Each loudspeaker must have a unique 
ID to be visible in the PRONET network. When you assign a new ID, all the other loudspeakers with the ID already assigned 
must be ON and connected to the network.

2)

 Pressing it with the unit ON you can select the DSP PRESET. The selected PRESET is indicated by the corresponding LED:

STANDARD 

This PRESET is suitable for any applica  on where low frequency reinforcement is required. It features a 90Hz cut o

  frequency 

and it can be used in almost any environment in combina  on with any ver  cal arrays.

INFRA 

This PRESET can be used when a deeper bass response is required (Note that when this preset is used the sound pressure level 
of the system is slightly reduced). NOTE: INFRA and STANDARD PRESET must NOT be used together in close units.

CARDIOID 

This special PRESET, combined with the STANDARD PRESET, gives the advantage to reduce the low frequencies at the back of 
an array of three subs, in order to obtain a more comfortable level for the performers on the stage without losing level for the 
the audience in front of the array. The cardioid con

fi

 gura  on is also useful in situa  on where you want to reduce the  bass 

frequency feedback due to many microphones on stage, for example for acous  c and jazz ensemble, classic orchestra, musicals. 
Further in this manual you can 

fi

 nd some example how to set up a cardioid array.  

USER 

This LED lights when the USER PRESET is loaded. This preset corresponds to USER MEMORY no. 1 of the DSP and, as a factory 
se   ng, it’s the same to STANDARD. If you want to modify it, you have to connect the unit to a PC, edit the parameters with 
PRONET so  ware and save the PRESET into USER MEMORY no. 1.

NETWORK IN/OUT -

 These are a standard RJ45 CAT5 connectors (with op  onal NEUTRIK NE8MC RJ45 cable connector carrier), used for PRONET 

network transmission of remote control data over long distance or mul  ple unit applica  ons. 

TERMINATE -

 In a PRONET network the last loudspeaker device must be terminated (with an inner load resistance) especially in a long run cabling: 

press this switch if you want to terminate the unit.

 

Содержание SW218A

Страница 1: ...8A subwoofer system is equipped with two high power 18 460mm transducers capable of long excursion up to 30mm peak to peak controlled by high s ness Double Silicon Spider as centering suspension and b...

Страница 2: ...nverter RAINCOV218 Rain protec on for connectors see h p www axiomproaudio com for detailed descrip on and other available accessories SPARE PARTS AC103GS 100 mm Swivel castor without brake AC115DN Bl...

Страница 3: ...the other loudspeakers with the ID already assigned must be ON and connected to the network 2 Pressing it with the unit ON you can select the DSP PRESET The selected PRESET is indicated by the corresp...

Страница 4: ...t documenta on The PRONET NETWORK is based on a robust reliable and fast communica on protocol called CANBUS The devices in a PRONET NETWORK are connected together with a linear bus topology The USB2C...

Страница 5: ...all cables before each installa on because even one faulty cable can compromise heavily the system performance INCLINOMETER WITH LEVER This tool can be used to verify the ver cal array angle It can b...

Страница 6: ...vel and delay se ng The figure below shows two typical displacement of the array The first with all the boxes in horizontal posi on for a total height of 1770 mm and a width of 1215 mm The second one...

Страница 7: ...e cardioid arrays keep a distance between them of at least 80 cm 2 6 in order not to maximize the combined radia on of whole arrays stage wall or other big ostacle bass sum direc on bass cancella on d...

Страница 8: ...product receipt SAFETY INSTRUCTIONS To reduce the risk close supervision is necessary when the product is used near children Protect the apparatus from atmospheric agents and keep it away from water r...