I/O AND CONTROL OPERATIONS

MAINS~ IN -

 Powercon® NAC3PX power inlet connector. To switch the amplifier on, 

insert the Powercon® connector and turn it clockwise into the ON position. To switch 

the amplifier off, pull back the switch on the connector and turn it counter-clockwise 

into the POWER OFF position.

MAINS~ OUT -

  Powercon®  NAC3PX  power  outlet  connector.  This  is  connected  in 

parallel with the MAINS~ IN.

WARNING! Connect no more than one subwoofer unit to the MAINS~ OUT 

connector.

WARNING! If you use the MAINS~ OUT turn on each subwoofer unit one a 

time. 

WARNING! In the case of product failure or fuse replacement, disconnect the 

unit completely from the mains power. 

WARNING!  Use  a  suitable  power  cable  and  mains  plug  to  build  the 

power cable, it  must only be connected to a socket corresponding to the 

specifications indicated on the amplifier unit.

See assembly instruction downloadable from NEUTRIK WEB site at: http://

www.neutrik.com/

CONTROL PANEL

ON - 

This LED indicates power on status.

PROT - 

This red LED lights when the amplifier module is in protect mode for an internal 

fault and, consequently, the amplifier is muted.

SIGN LIMIT - 

This LED lights in green to indicate the presence of the signal and lights 

in red when an internal limiter reduces the input level.

INPUT -

 Audio signal input with locking XLR connector. It has a fully electronically 

balanced circuitry including AD conversion for the best S/N ratio and input headroom.

LINK -

 A direct connection from the input connector to link other speakers with same 

audio signal.

GND LIFT -

 This switch lift the ground of the balanced audio inputs from the earth-

ground of the amplifier module.

PRESET BUTTON - 

This button has two function:

1)

 Pressing it while powering on the unit:

ID ASSIGN

 

the internal DSP assigns a new ID to the unit for the PRONET remote 

control operation. Each loudspeaker must have a unique ID to be 

visible in the PRONET network. When you assign a new ID, all the 

other loudspeakers with the ID already assigned must be ON and 

connected to the network.

2)

 Pressing it with the unit ON you can select the DSP PRESET. The selected PRESET 

is indicated by the corresponding LED:

STANDARD 

This PRESET is suitable for any application where low frequency 

reinforcement is required. It features a 90Hz cut off frequency and 

it can be used in almost any environment in combination with any 

vertical arrays.

INFRA 

This PRESET can be used when a deeper bass response is required 

(Note that when this preset is used the sound pressure level of the 

system is slightly reduced). NOTE: INFRA and STANDARD PRESET 

must NOT be used together in close units.

CARDIOID 

This special PRESET, combined with the STANDARD PRESET, gives the 

advantage to reduce the low frequencies at the back of an array of three subs, in order to 

obtain a more comfortable level for the performers on the stage without losing level for the 

the audience in front of the array. The cardioid configuration is also useful in situation where 

you want to reduce the  bass frequency feedback due to many microphones on stage, for 

example for acoustic and jazz ensemble, classic orchestra, musicals. Further in this manual 

you can find some example how to set up a cardioid array.  

USER 

This LED lights when the USER PRESET is loaded. This preset corresponds to USER MEMORY 

no. 1 of the DSP and, as a factory setting, it’s the same to STANDARD. If you want to modify 

it, you have to connect the unit to a PC, edit the parameters with PRONET software and save 

the PRESET into USER MEMORY no. 1.

NETWORK IN/OUT -

 These are a standard RJ45 CAT5 connectors (with optional NEUTRIK NE8MC RJ45 cable 

connector carrier), used for PRONET network transmission of remote control data over long distance or multiple 

unit applications. 

TERMINATE -

  In  a  PRONET  network  the  last  loudspeaker  device  must  be  terminated  (with  an  inner  load 

resistance) especially in a long run cabling: press this switch if you want to terminate the unit.

 