EP500 v2 & EP600 v2 - ELECTRICAL CONNECTIONS

Step 1:

LINE IN:

 the RCA line-level female input, second row, accepts a standard 

RCA male plug. Connect a shielded coaxial cable, with male RCA plugs on 

each end, from the A/V receiver or A/V preamp processor’s Subwoofer Output 

jack to the RCA LINE IN female jack on the EP500 v2 or EP600 v2.

3.5mm MINI-Jack: this is for any 3Volt to 30Volt power on trigger. It is also 

intended for trigger-controlled operation with future Axiom products.

BALANCED XLR LINE IN:

 if the A/V receiver or A/V preamp-processor has 

balanced XLR subwoofer line-out connections, you may connect a Balanced 

XLR male connector to the XLR female input. Otherwise, ignore this connector. 

Do not use a combination of RCA and XLR input or output connectors. 

HIGH LEVEL INPUT:

 Use these “speaker-level” or high-level 5-way binding 

post connectors only if your receiver or preamp lacks a dedicated line-level 

subwoofer  output  jack.  Connect  speaker  cables  from  your  amplifier’s  left-

channel  and  right-channel  speaker  output  binding  posts  to  the  high-level 

inputs using banana plugs (single or dual), spade connectors, pins, or bare 

cable if you wish (unscrew the top of each binding post and insert the cable 

into the hole in the post; tighten the knurled knob against the cable). Run a 

second pair of speaker cables from these jacks to your main left and right 

front speakers.  Do not use these connectors if you are already using an RCA 

or XLR line-level connection from the receiver or preamp to the subwoofer. 

NOTE: BE SURE TO CONNECT BLACK TO BLACK AND RED TO RED.

Step 2:

LINE OUT (RCA, Trigger and XLR Balanced):

An  RCA  line-level  (female)  output  and  balanced  XLR  output  (male)  are 

provided  for  connection  to  a  second  subwoofer.  Use  a  standard  shielded 

coaxial cable for connection of the RCA Line Out to the second subwoofer. If 

you are using balanced XLR connectors, then use the balanced Line Out for 

operation of a second EP500 v2 or EP600 v2.

Step 3:

CROSSOVER:

  if  you  are  using  the  Bass  Management  crossover  menu 

settings in your A/V receiver or processor, turn this control to “BYPASS” to 

eliminate the EP500 v2 or EP600 v2 internal crossover from the circuit. 

If you are using the HIGH LEVEL (Speaker Level) binding-post inputs, set the 

crossover switch to 80 Hz for initial setup. If you have floor-standing speakers 

(M50 v2, M60 v2, or M80 v2), try a 60 Hz crossover frequency, for the M80 

v2 try 40 Hz. If your main speakers are bookshelf models M3 v2 or M22 v2, 

try the 80 Hz setting, for the M2 v2 try 100 Hz.  Ultimately you want to use a 

crossover frequency that produces the smoothest blend of sound between the 

subwoofer and your main speakers.

Step 4:

VOLUME:

 Set this midway to the 9 o’clock position for initial setup. You can 

use this to manually regulate the subwoofer volume at any time and during 

your initial setup adjustments with the other speakers in your stereo or home 

theater system.

Step 5:

ON/OFF AC POWER/VOLTAGE SETTING:

 Your subwoofer is supplied with 

a pop-out voltage regulator set for use with 100 - 120 volts from the A/C line. 

It can be easily removed and turned over to set your EP500 v2 or EP600 v2 

to 220 volts from the A/C line. See diagrams on the next page. 

The EP500 

v2 & EP600 v2 come with a three prong power cord compatible throughout 

the  United  States  and  Canada.  Other  International  countries  will  need  to 

purchase  a  converter/adaptor  or  the  proper  power  cord  according  to  your 

specific socket.

Once  you  have  made  appropriate  connections  from  the  A/V  receiver  or 

preamp/processor to the EP500 v2 or EP600 v2 and set the voltage regulator 

to the proper voltage, find a nearby AC wall outlet and connect the main power 

cord to the three-wire socket at the bottom of the control panel. Move the 

power switch to the ON setting and the LED POWER indicator should glow 

Green. Leave the switch at the ON setting unless you go away for an extended 

period. Moving it to OFF will shut down all power to the subwoofer.

Step 6:

0 & 180 PHASE:

 This synchronizes the in/out movement of the subwoofer 

cone driver with the other speakers in your system. Once you have chosen 

the best location for your subwoofer, try flipping the phase switch between 

0 and 180 to see if one or the other setting produces deeper and smoother 

bass output in your room. Leave the switch at the setting that results in the 

smoothest and deepest bass at several listening locations in the room. If you 

hear no difference, leave the switch at the 0 position. Quite often the phase 

switch makes no difference, but it’s dependent on your room and subwoofer 

location.

Step 7:

TRIM:

  Set  this  to  FLAT  for  normal  subwoofer  operation  in  a  large  room. 

The  subwoofer  will  reproduce  deep  bass  at  normal  levels  from  the  movie 

soundtrack or music sources. The LOAD setting is for accessing the internal 

microprocessor. Do not use this setting as it will turn off the sub output and turn 

the light amber. The REMOTE setting is for operation with future Axiom remote 

controlled  products  that  enables  remote-control  adjustment  of  subwoofer 

levels. If you are in a medium or small room you should experiment with Half 

and Full to compensate for room loading. Setting the TRIM to Half will partially 

increase frequencies above 33 Hz and Full will greatly increase frequencies 

above 33 Hz. This may be necessary to overcome room loading or boundary 

effect (too much low bass).

Step 8:

GROUND LOOP:

If your subwoofer is producing a 60 Hz hum, remove the Chassis Ground 

Screw. If this does not solve the 60 Hz hum, call 1-866-244-8796 or consult 

the full manual at 

www.axiomaudio.com/manual_ep500600.html

POWER INDICATOR:

 The LED Power indicator glows Green when it’s on and 

Yellow indicating a fault.

USB:

 This is to be used for future software upgrades to the Digital Signal 

Processor inside your EP500 v2 and EP600 v2. You may also use the 

USB input to connect the accessory Axiom light to ease visibility in making 

subwoofer adjustments or connections.

Visit 

www.axiomaudio.com/manual_index.html 

for full owners manual

Содержание EP500 v2

Страница 1: ... EP500 v2 EP600 v2 Quick Setup Guide Epicenter ...

Страница 2: ...have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the apparatus 16 To completely disconnect this apparatus from the AC Mains disconnect the power supply cord plug from the AC receptacle 17 T...

Страница 3: ...ay that sound is measured and allows Axiom to provide the world s most realistic sounding loudspeakers at amazing value to the consumer By emphasizing the practical side of our ongoing research Axiom continues to extend people s expectations of performance It is our central goal at Axiom to turn this research into a truly exciting experience for you in your environment Our commitment to the delive...

Страница 4: ...em Step 5 ON OFF AC POWER VOLTAGE SETTING Your subwoofer is supplied with a pop out voltage regulator set for use with 100 120 volts from the A C line It can be easily removed and turned over to set your EP500 v2 or EP600 v2 to 220 volts from the A C line See diagrams on the next page The EP500 v2 EP600 v2 come with a three prong power cord compatible throughout the United States and Canada Other ...

Страница 5: ... further assistance please visit www axiomaudio com archives subsetup html TROUBLESHOOTING For further assistance please visit www axiomaudio com troubleshooting_ep500 html or www axiomaudio com troubleshooting_ep600 html Step 5 For 220 volt supply only ...

Страница 6: ...level input RCA male jacks at both ends USB LIGHT The Axiom USB Light provides much needed illumination when adjusting controls or connecting wires behind your Epicenter EP500 v2 or Epicenter EP600 v2 subwoofers The small flexible light plugs into your EP500 v2 and EP600 v2 It can also plug into any Laptop Notebook PC Macintosh monitor or any device with an available USB port USB 1 1 or USB 2 0 Al...

Страница 7: ... Nord 1 888 249 9143 Worldwide International 1 705 635 3090 Email Courriel info axiomaudio com www axiomaudio com For further infomation about your product please see our Manual Index at www axiomaudio com manual_index html Pour des renseignements complémentaires sur votre produit consultez notre index de manuel au www axiomaudio com manual_index html ...

Отзывы: