Assign the ID number
To work properly in a PRONET network each connected device must have a unique iden
fi
er number, called ID. By default the USB2CAN PC
controller has ID=0 and there can be only one PC controller. Every other device connected must have its own unique ID equal or greater than 1:
in the network cannot exist two devices with the same ID.
An ID number is assigned automa cally to each devices when they are turned on for the
fi
rst me connected to a network.
In order to correctly assign a new available ID to each device for working properly in a Pronet network, follow these instruc ons:
1.
Switch o
ff
all the devices.
2.
Connect them correctly to the network cables.
3.
“TERMINATE” the latest device in the network connec on.
4.
Switch on the
fi
rst device keep pressed “PRESET” bu on on the control panel.
5.
Leaving the previous device switched on, repeat the previous opera on on the next device, un l the latest device is turned on.
The “Assign ID” procedure for a device makes the internal network controller to perform two opera ons: reset the current ID; search the
fi
rst free
ID in the network, star ng from ID=1. If no other devices are connected (and powered on), the controller assume ID=1, that is the
fi
rst free ID,
otherwise it searches the next one le free.
These opera ons ensure that every device has it’s own unique ID, if you need to add a new device to the network you simply repeat the opera on
of step 4. Every device maintains its ID also when it is turned-o
ff
, because the iden
fi
er is stored in the internal memory and it is cleared only by
another “Assign ID” step, as explained above. This means that if your network is made always of the same devices the assigning ID procedure must
be executed only the
fi
rst me the system is turned on.
For more detailed instruc
Ɵ
on about PRONET see the PRONET USER’S MANUAL included with the so
Ō
ware.
do not
pressed
pressed
LAST DEVICE
network
network
FIRST DEVICE
AND FOLLOWING
USB2CAN
PC NOTEBOOK
USB 2.0 port
ST
A
TU
S
CO
N
V
ER
TE
R
USB2CAN
CODE:
S/N:
RA
TINGS:
RoHS COMPLIANT
MADE IN IT
AL
Y
USB2CAN
00001
5V --- 200mA
EXAMPLE OF PRONET NETWORK WITH CX15A WEDGE MONITOR