Axiohm TELESTO Скачать руководство пользователя страница 9

 

TELESTO Set-Up Guide 

page 9 / 9 

Reference : FDE-3108164-A 

 

 

CLEANING YOUR PRINTER 

Depending on the environment in which the printer is used, it can accumulate dust. Therefore it is necessary 
to clean it periodically to maintain a good print quality. The cleaning period depends on the environment and 
the usage of the printer, but the printhead should be cleaned at least once a year, and up to one month in case 
of heavy duty applications.  

 Cleaning 

Instructions: 

„

 

Unplug the printer.

 Never clean the head immediately after printing, the head may be hot. 

„

 

Open the cover, clean the heating dots line of the head with a cotton stick containing a solvent 
alcohol (ethanol, methanol, or IPA) but

 do not touch the printhead with your fingers

!

 

„

 

Allow the solvent to dry and close the cover.

 

N.B : AXIOHM can also provide cleaning kits with the instructions to use it. The kit reference is 

CK80000A. 

 
 

GENERAL INFORMATION 

 

 

Power Supply: 

UL Listed power supply with SELV (Secondary Extra Low Voltage) non energy hazard output, 
limited energy source input rated 100-240 Vac, 2.0 A, 50/60 Hz, output rated 24 Vdc, 4.3 A for 75 
watt unit. 
Product characteristics are guaranteed with Axiohm power supply reference 3108213 

 

 

Communication Interface Cable: 

A shielded interface cable must be used with this product. The shield must be connected to the frame 
or earth ground connection or earth ground reference at EACH end of the cable. 
Use of a cable other than described here will require that you test the cable with the Axiohm printer 
and your system for FFC and CE mark certification. 
 

 

Power Cord: 

A UL listed, detachable power cord must be used. The printer side power connector must remain 
available when the printer is installed. 
 

 

Max duty cycle:

 

 - Printing: 20% 
 - Cutter: 8% 

 

 

CDKO: 

 - Driving voltage: 24 VDC 
 - Driving current: Approx. 1A max. (shall not exceed 510ms) 

 

For complementary information, please see the Axiohm 3108271 user manual 

Содержание TELESTO

Страница 1: ...M 1 Rue d Arcueil BP 820 92542 Montrouge Cedex France Tel 33 0 1 58 07 17 17 Fax 33 0 1 58 07 17 18 www axiohm com 1 9 THERMAL PRINTING SOLUTIONS SET UP GUIDE TELESTO Printer Reference FDE 3108164 Iss...

Страница 2: ...CRIPTION 3 TECHNICAL SPECIFICATIONS 4 DELIVERY INSTALLATION 5 PRINTER LOCATION 5 CONNECTING THE POWER SUPPLY AND INTERFACE ON TELESTO 5 PAPER FEED BUTTON 6 PAPER LOADING 6 SELF TEST TICKET DESCRIPTION...

Страница 3: ...ence FDE 3108164 A YOUR PRINTER Package The packing box contains Printer Power supply power card depending on versions Paper roll Set Up Guide Screw driver General description Paper feed button LED in...

Страница 4: ...odes supported Code 39 Code 128 A B et C JAN 8 13 Interleaved 2 of 5 Codabar Emulation Esc PosTM Automatic cutter Full or partial cut Interfaces USB RS CDKO Paper roller width Paper roller external di...

Страница 5: ...ed temperature from 5 to 45 C for operating 20 to 60 for storage no risk of water exposure no mechanical stress it is recommended to avoid the mechanical vibrations Connecting the power supply and int...

Страница 6: ...printer is ready to print The light is flashing if the printer runs out of paper See troubleshooting for other flashing modes Paper Loading Step n 1 Push button to open lid Step n 2 See indications fo...

Страница 7: ...TION To print a self ticket open the lid push the paper feed button until the light turns off approx 10s when the light is off immediately close the lid keeping the feed button pressed RS232 USB If yo...

Страница 8: ...se the cover with wrinkled part out and cut it with the tear bar Printing quality is deteriorating The printhead may be getting dirty see next chapter No printing Check the correct position of the pap...

Страница 9: ...it The kit reference is CK80000A GENERAL INFORMATION Power Supply UL Listed power supply with SELV Secondary Extra Low Voltage non energy hazard output limited energy source input rated 100 240 Vac 2...

Отзывы: