background image

Operation instructions | UIM 1-00 | Universal Input Modulator

Page 10 of 20

AXING-BA_UIM-1-00.pdf | Technical improvements, changes in design, printing and other errors reserved. |  2021-11-03

3.2. Performing a channel search

è

You must perform a channel search on the connected TV sets or search directly for the selected output
channel.
If the station is found, the AXING logo is displayed as the factory setting.
The

LCN

 entered is displayed as the programme number, and the name entered under

Service

 is displayed

as the station name.

3.3. Reset to factory settings

You can reset the device completely to factory settings.

è

Press the reset button for longer than 5 seconds.
The device is rebooted and completely reset to the factory settings.
This also includes the password of the web interface, the IP addresses of the interfaces and the output
channel.

Programme

number and

station name

Содержание UIM 1-00

Страница 1: ...UIM 1 00 Universal Input Modulator Betriebsanleitung ...

Страница 2: ...ng 7 2 2 5 Stromversorgung 7 3 Bedienung 8 3 1 Konfiguration des Ausgangsmodulators mit den Bedientasten 9 3 2 Sendersuchlauf durchführen 10 3 3 Auf Werkseinstellungen zurücksetzen 10 4 Konfiguration im Webbrowser 11 4 1 Status 12 4 2 Media Source 13 4 2 1 IP Streaming 13 4 2 2 Videos von einem USB Stick Laufwerk 13 4 2 3 M3U Playlist 13 4 2 4 HDMI Input 13 4 3 Modulator 14 4 3 1 Standard DVB T 14...

Страница 3: ...s Sicherheitshinweise_9sprachig pdf èBenutzen Sie das Gerät ausschließlich wie in dieser Betriebsanleitung beschrieben und insbesondere nach dem Stand der Technik Wird das Gerät für andere Einsätze verwendet wird keine Gewährleistung übernommen CE Konfirmationserklärung Hiermit erklärt die AXING AG dass die gekennzeichneten Produkte den geltenden Richtlinien entsprechen WEEE Nr DE26869279 Elektris...

Страница 4: ...tz ein Der UIM 1 00 moduliert das Video in einen DVB C oder DVB T Kanal Das Video kann an einem Fernsehgerät das mit DVB C T Tuner ausgestattet ist empfangen werden Im abgebildeten Beispiel wird ein Video in eine Kopfstellenanlage eingespeist Der UIM 1 00 muss so konfiguriert werden dass der eingestellte Ausgangskanal keinen Kanal der Kopfstelle stört oder überlappt Zum Einspeisen wird die als Zub...

Страница 5: ...pdf Seite 5 von 20 1 2 Anzeige Bedienelemente und Anschlüsse 1 Display 8 HF Ausgang 2 Bedientasten hoch runter links rechts 9 Reset Taste 3 Enter Taste 10 NMS Konfigurations Schnittstelle 4 ESC Taste Abbrechen Zurück 11 DATA Schnittstelle 5 Status und Power LED 12 HDMI Eingang 6 DC Eingang 13 USB Port 7 Ventilator ...

Страница 6: ...rbehalten 2021 11 01 2 Montage und Anschluss 2 1 Montage Das Gerät darf nicht durch die angeschlossenen Kabel gehalten werden èMontieren Sie sie beiliegenden Montagewinkel mit den mitgelieferten Senkkopfschrauben am Gerät èMontieren Sie das Gerät auf einer flachen Oberfläche Verwenden Sie passende Montageschrauben Montagewinkel mit mitgelieferten Senkkopfschrauben ...

Страница 7: ...der mit der IPTV Quelle verbunden ist Verwenden Sie dazu Class 5 6 Ethernet Kabel mit RJ 45 Steckern 2 2 3 USB Port èSchließen Sie einen USB Stick oder ein USB Laufwerk am USB Port an 2 2 4 HF Ausgang èVerbinden Sie den Ausgang RF mit dem vorhandenen Verteilnetz Verwenden Sie hierfür ein hochgeschirmtes Koaxialkabel mit einem F Anschlussstecker èUm den Außenleiter des Koaxialkabels am Potentialaus...

Страница 8: ...gn Druckfehler und Irrtümer vorbehalten 2021 11 01 3 Bedienung Nach dem Einschalten leuchtet die PWR LED rot und der Lüfter läuft Das Gerät bootet und die Firmwareversion wird angezeigt Sobald der Bootvorgang abgeschlossen ist leuchtet die Status LED blau und auf dem Display wird die Ausgangsmodulation und der Ausgangskanal angezeigt ...

Страница 9: ... eines Kanals ein Sie müssen einen freien Kanal in Ihrem TV Netz wählen Beim Parameter Service stellen Sie mit einem aplhanumerischen Menü einen Servicenamen ein Dieser erscheint als Programmname im Fernsehgerät Beim Parameter LCN stellen Sie die Programmnummer ein Diese darf nicht mit schon vorhandenen Programmnummern kollidieren Sie müssen eine freie LCN auswählen èDrücken Sie die ESC Taste um d...

Страница 10: ...r Sender gefunden dann wird als Werkseinstellung das AXING Logo eingeblendet Als Programmnummer wird die eingegebene LCN als Sendername der unter Service eingegeben Name eingeblendet 3 3 Auf Werkseinstellungen zurücksetzen Sie können das Gerät komplett auf Werkseinstellungen zurücksetzen èDrücken Sie die Resettaste länger als 5 Sekunden Das Gerät wird neu gebootet und komplett auf die Werkseinstel...

Страница 11: ...die NMS Konfigurations Schnittstelle sind ab Werk folgenden IP Adressdaten eingestellt IP Adresse 192 168 0 168 Subnetz Maske 255 255 255 0 Ihr PC muss sich im selben IPv4 Netzwerkabschnitt befinden èÄndern Sie die IP Adresse Ihres PC Laptop z B auf 192 168 0 1 Subnetz Maske 255 255 255 0 èSchließen Sie den PC am RJ 45 Ethernet Anschluss NMS an èGeben Sie die IP Adresse des UIM 1 00 in die Adressz...

Страница 12: ...Die Firmware kann ggf upgedated werden siehe 4 5 auf Seite 18 Unter Modulator wird der Modulator Typ seine Firmwareversion und das ausgegebene Video Format angezeigt Die Firmware kann ggf upgedated werden siehe 4 5 auf Seite 18 Unter Player werden folgende Daten angezeigt Die Firmware Version des UIM 1 00 Die IP Adressdaten der Player DATA Schnittstelle Daten zum an der USB Schnittstelle angeschlo...

Страница 13: ...ternet gestreamt 4 2 2 Videos von einem USB Stick Laufwerk èUm ein Videos von einem USB Stick Laufwerk zu streamen wählen Sie das Video im Feld Videos aus und klicken Sie auf Play èUm alle Videos auszuwählen und abzuspielen klicken Sie auf Select All und anschließend auf Play èKlicken Sie Refresh die Inhalte werden aktualisiert èKlicken Sie Remove der USB Stick oder das USB Laufwerk wird ausgeworf...

Страница 14: ...eter Bereich Anmerkung Standard DVB T RF Freq MHz 100 950 Geben Sie die Mittenfrequenz eines DVB T Kanals ein Sie müssen einen freien Kanal in Ihrem TV Netz wählen Bandwidth MHz 6 7 8 Modulation QPSK 16QAM 64QAM RF Attenuation dB 0 30 Verringert den Ausgangspegel um 0 bis 30 dB LCN 1 1023 Sie müssen eine freie LCN auswählen Program Number 1 65535 TS ID 1 65535 Network ID 1 65535 ON ID 1 65535 Prov...

Страница 15: ...rlace Audio format AAC MPEG1 Half FPS On Off 4 3 2 Standard DVB C Wenn als Standard DVB C ausgewählt ist dann werden folgende Felder angezeigt Parameter Bereich Anmerkung Standard DVB C RF Freq MHz 100 950 Geben Sie die Mittenfrequenz eines DVB C Kanals ein Sie müssen einen freien Kanal in Ihrem TV Netz wählen Symbol Rate Ksps 5000 8000 Typischer Wert 6900 Modulation 16QAM 32QAM 64QAM 128QAM 256QA...

Страница 16: ... Sie die Einstellungen für den UIM 1 00 vor 4 4 1 NMS Netzwerk Management System Hinweis Setzen Sie die IP Adresse von NMS und Player nicht auf die gleiche Adresse Unter NMS nehmen Sie die IP Einstellungen der NMS Schnittstelle vor also der Schnittstelle über die der UIM 1 00 konfiguriert wird Das Netzwerk Management System des UIM 1 00 unterstützt keinen DHCP Server es muss eine feste IP Adresse ...

Страница 17: ... IP Adress eine freie IP Adresse aus Ihrem Netzwerk ein èGeben Sie die Subnetzmaske Ihres IP Netzes in das Feld Subnet Mask ein i d R lautet diese 255 255 255 000 èGeben Sie in das Feld Default Gateway die Adresse des Gateways Ihres Netzwerks ein i d R die IP Adresse des Routers Im Feld MAC Adress sehen Sie die MAC Adresse der DATA Schnittstelle des UIM 1 00 èNach dem Sie die Einstellungen vorgeno...

Страница 18: ...ur ein Update nach dem anderen durch èTrennen Sie während dem Update das Gerät nicht von der Stromversorgung èStellen Sie vor dem Update der NMS und der USB Firmware sicher dass das Internetverbindung stabil ist èKlicken Sie auf die entsprechnde Update Schaltfläche Der Update Verlauf wird Ihnen unter Progress mit dem Fortschrittsbalken angezeigt Nach dem Update dauert es eine Weile bis das Gerät a...

Страница 19: ...0 Hz Ausgangsmodulation Typ 64QAM 128QAM 256QAM DVB C QPSK 16QAM 64QAM DVB T Unterstützte Ausgangsformate H 264 MPEG 4 MER Typ 35 dB FFT 2K 8K DVB T FEC 1 2 3 5 2 3 3 4 5 6 7 8 DVB T Schutzintervall 1 4 1 8 1 16 1 32 DVB T Symbolrate 5 8 MBaud s Schnittstellen IPTV Eingang 1 x RJ45 Konformität IPTV Schnittstellen IEEE 802 3 10 100 Base T Konfigurations Schnittstelle 1 x RJ45 Konformität Konfigurat...

Страница 20: ...Betriebsanleitung UIM 1 00 Universal Input Modulator Seite 20 von 20 AXING BA_UIM 1 00 pdf Technische Verbesserungen Änderungen im Design Druckfehler und Irrtümer vorbehalten 2021 11 01 ...

Страница 21: ...UIM 1 00 Universal Input Modulator Operation instructions ...

Страница 22: ...B Port 7 2 2 4 RF output 7 2 2 5 Power Supply 7 3 Operation 8 3 1 Configuration of the output modulator with the operating keys 9 3 2 Performing a channel search 10 3 3 Reset to factory settings 10 4 Configuration in the web browser 11 4 1 Status 12 4 2 Media Source 13 4 2 1 IP streaming 13 4 2 2 Videos from a USB stick drive 13 4 2 3 M3U Playlist 13 4 2 4 HDMI Input 13 4 3 Modulator 14 4 3 1 Stan...

Страница 23: ...xing com BAs Sicherheitshinweise_9sprachig pdf èOnly use the unit as described in these operating instructions and in particular according to the state of the art If the unit is used for other applications no warranty is given CE Confirmation Statement AXING AG hereby declares that the labelled products comply with the applicable directives WEEE No DE26869279 Do not dispose of electrical and elect...

Страница 24: ...oaxial cable network The UIM 1 00 modulates the videos into a DVB C or DVB T channel These can then be received on a television set equipped with a DVB C T tuner In the example above a video is fed into a headend system The UIM 1 00 must be configured so that the set output channel does not interfere or overlap with a channel of the headend The RF inserter TZU 40 05 which is available as an access...

Страница 25: ...BA_UIM 1 00 pdf Page 5 of 20 1 2 Display operating elements and connections 1 Display 8 RF output 2 Operation keys up down left right 9 Reset button 3 Enter key 10 NMS control interface 4 ESC key cancel back 11 DATA interface 5 Status and power LED 12 HDMI input 6 Power input 13 USB port 7 Fan ...

Страница 26: ...nting and other errors reserved 2021 11 03 2 Mounting and Installation 2 1 Mounting The device must not be held by the connected cables èMount the enclosed mounting brackets on the unit using the supplied countersunk screws èMount the device on a flat surface Use suitable mounting screws Mounting bracket with supplied countersunk screws ...

Страница 27: ...o an Ethernet switch connected to the IPTV source Use Class 5 6 Ethernet cables with RJ 45 connectors 2 2 3 USB Port èConnect a USB stick or USB drive to the USB port 2 2 4 RF output èConnect the output RF to the existing distribution network For this purpose use a highly shielded coaxial cable with an F connector plug èTo connect the outer conductor of the coaxial cable to the equipotential bondi...

Страница 28: ...es in design printing and other errors reserved 2021 11 03 3 Operation After switching on the PWR LED lights up red and the fan runs The unit boots and the firmware version is displayed As soon as the boot process is completed the status LED lights up blue and the display shows the output modulation and the output channel ...

Страница 29: ...set the channel number or the centre frequency of a channel You must select a free channel in your TV network With the Service parameter you set a service name with an aplhanumeric menu This appears as the programme name in the TV set In the LCN parameter set the programme number This must not collide with existing programme numbers You must select a free LCN èPress the ESC key to exit the menu A ...

Страница 30: ...ation is found the AXING logo is displayed as the factory setting The LCN entered is displayed as the programme number and the name entered under Service is displayed as the station name 3 3 Reset to factory settings You can reset the device completely to factory settings èPress the reset button for longer than 5 seconds The device is rebooted and completely reset to the factory settings This also...

Страница 31: ...led web browser The following IP address data is set ex factory for the NMS control interface IP adresse 192 168 0 168 Subnet mask 255 255 255 0 Your PC must be in the same IPv4 network section èChange the IP address of your PC laptop e g to 192 168 0 11 subnet mask 255 255 255 0 èConnect the PC to the RJ 45 Ethernet port NMS èEnter the IP address of the device in the address line of your browser ...

Страница 32: ...S interface are displayed The firmware can be updated if necessary see 0 on page 17 Under Modulator the modulator type its firmware version and the output video format are displayed The firmware can be updated if necessary see 0 on page 17 The following data is displayed under Player The firmware version of the UIM 1 00 The IP address information of the player DATA interface Information of the USB...

Страница 33: ...d e g https youtu be xx65dLA08u4 èClick Apply The video is streamed from the Internet 4 2 2 Videos from a USB stick drive èTo stream a video from a USB stick drive select the video in the Videos field and click Play èTo select and play all videos click Select All and then Play èClick Refresh the contents are updated èClick Remove the USB stick drive is ejected You can then remove the USB device fr...

Страница 34: ... MHz 100 950 Enter the centre frequency of a DVB T channel You must select a free channel in your TV network Bandwidth MHz 6 7 8 Modulation QPSK 16QAM 64QAM RF Attenuation dB 0 30 Reduces the output level by 0 to 30 dB LCN 1 1023 You must select a free LCN Program Number 1 65535 TS ID 1 65535 Network ID 1 65535 ON ID 1 65535 Provider Name Up to 15 alphanumeric characters Service Name Up to 15 alph...

Страница 35: ...dard DVB C Parameter Range Comment Standard DVB C RF Freq MHz 100 950 Enter the centre frequency of a DVB T channel You must select a free channel in your TV network Symbol Rate Ksps 5000 8000 6900 typical Modulation 64QAM 128QAM 256QAM RF Attenuation dB 0 30 Reduces the output level by 0 to 30 dB LCN 1 1023 You must select a free LCN Service ID 1 65535 TS ID 1 65535 Network ID 1 65535 ON ID 1 655...

Страница 36: ...werk Management System Note Do not set the IP address of NMS and player to the same address Under NMS make the IP settings of the NMS interface the interface by which the UIM 1 00 is configured The network management system of the UIM 1 00 does not support a DHCP server a fixed IP address must be entered èEnter a free IP address from your network in the IP Address field èEnter the subnet mask of y...

Страница 37: ... of the IP data are displayed èEnter a free IP address from your network in the IP Address field èEnter the subnet mask of your IP network in the Subnet Mask field this is usually 255 255 255 000 èIn the Default Gateway field enter the address of the gateway of your network usually the IP address of the router èAfter you have made the settings click Apply The settings are applied 4 4 3 Password Co...

Страница 38: ...orm one update at a time èDo not disconnect the device from the power supply during the update èBefore updating the modulator firmware and the firmware for the LCD module make sure that the Internet connection is stable èClick on the corresponding update button The update progress is displayed under Progress with the progress bar After the update it takes a while until the device restarts automati...

Страница 39: ...60 Hz Output modulation Type 64QAM 128QAM 256QAM DVB C QPSK 16QAM 64QAM DVB T Supported output formats H 264 MPEG 4 MER Typ 35 dB FFT 2K 8K DVB T FEC 1 2 3 5 2 3 3 4 5 6 7 8 DVB T Guard interval 1 4 1 8 1 16 1 32 DVB T Symbol rate 5 8 MBaud s Interfaces IPTV input 1 x RJ45 Compliance IPTV interface IEEE 802 3 10 100 Base T Configuration interface 1 x RJ45 Compliance configuration interface IEEE 80...

Страница 40: ...Operation instructions UIM 1 00 Universal Input Modulator Page 20 of 20 AXING BA_UIM 1 00 pdf Technical improvements changes in design printing and other errors reserved 2021 11 03 ...

Отзывы: