Field of application:

The devices are only suitable for in-house distribution of RF signals. 
SVS XXXX-06 can be used as input or trunk amplifier befor or between SPU 
XXXX-06 multiswitches/cascade units.
If a device is used for other purposes, no warranty is given!
The figure on the right show an application example for distribution of 8 SAT 
IF polarization levels including terrestrial signals (e.g. DAB+ radio).

RF Installation:

 

Use highly shielded coaxial cables with F connectors. Suitable cables and 
connectors can be found in the current AXING catalogue or under www.
axing.com.

Adjustments:

The input levels can be adjusted from 0 to 15 dB (5).

Power supply:

The devices can be supplied remotely via the inputs or outputs or can be 
supplied via an external power supply SZU 99-06 (not included in delivery)

The 

Remote Power on / off

 switch (4) blocks or routes the DC voltage to 

the outputs.

Remote supply by other devices:

 

Turn the switch on: 
The amplifier is supplied via its inputs or its outputs.

 

Turn off the switch to off: 
The DC connection to the outputs is blocked. 
The amplifier is only supplied via its inputs.

Operation with power supply and remote feeding of other devices:

 

Connect the power adapter to the DC jack (3).

 

Turn on the Remote Power switch on: 
The DC voltage is forwarded to the inputs and outputs. 
Downstream devices at the outputs and upstream devices at the inputs 
are also powered.  

Avoid parallel operation with external power 

supply and / or remote feed on both sides!

 

Turn off the switch to off: 
The DC connection to the outputs is blocked. 
Only upstream devices at the inputs are supplied.

Meaning of the LED displays:

Remote Power 

Switch

LED 1

LED 2

Power supply connected

OFF

Off

On

ON

On

On

Remote supply voltage from 
other devices at the inputs

OFF

Off

On

ON

On

On

Remote supply voltage from 
other devices at the outputs

OFF

On

Off

ON

On

On

Equipotential bonding and mounting:

To avoid dangerous power surges (e.g. risk of fire and danger of life) the 
devices must be connected to the equipotential bonding according to  
EN 60728-11.

 

Use the equipotential bonding connection at the device (1).

 

To connect the outer conductor of the coaxial cable to the equipotential 
bonding, use e.g. QEW Earthing angles at the inputs and outputs of the 
device. 

 

Use appropriate mounting screws and the mounting holes of the device (2).

Inputs (SAT system 1)

Inputs (SAT system 2)

TERR Input

Outputs (SAT system 1)

Outputs (SAT system 2)

TERR Output

4

LED 2

1
2

1

2

LED 1

3

5