State of the art 2017-01-27 - Technical changes, design modifications, 
errors and misprints are subject to change without prior notice.

Safety advice:

4

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

4

Before opening the equipment pull out the power plug or remove the 
power supply, otherwise there is danger of electrocution. This is also 
valid for cleaning the equipment or working on the connections. 

4

Providing that a serviceable fuse exists, the power plug must be pulled 
out before changing the fuse. Defective fuses may only be replaced with 
standard compliant fuses that have the same nominal value.

4

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire) or 
electrocution.

4

To prevent damage to your equipment and to avoid possible peripheral 
damages, the devices foreseen for wall mounting may only be installed 
on a flat surface.

4

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. The mains cable as well as feeder lines may not be 
damaged or clamped by objects of any kind. 

4

Choose the location of installation or mounting so that under no 
circumstances liquids or objects can get into the equipment (e.g. 
condensation, water coming from leaking roofs or flowing water, etc.).

4

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible 
damage to the equipment as well as a risk of fire caused by 
overheating. Absolutely avoid that cables come near any source of heat 
(e.g. radioators, other electrical devices, chimney, etc.).

WEEE Nr. 

DE26869279

Your device is marked with the WEEE symbol (Waste Electronics 
and Electrical Equipment). This means that the electrical and 
electronic components must not be disposed of as residual waste. 
Used electrical and electronic components must be disposed of 
separately.

SKT 20-20M
SKT 40-20M | SKT 80-20M
SKT 40-24M | SKT 80-22M

Multituner | DVB-T2 
twin/quattro/octo module

Quick start guide

Manufacturer
AXING AG 
Gewerbehaus Moskau
     8262 Ramsen 

EWR contact adress
Bechler GmbH
Am Rebberg 44
     78239 Rielasingen

Technical Data:

 

 

SKT 20-20M

Ducts 

 

2

Multituner 

 

2 × DVB-S/S2/T/T2/C

 

Inputs 

 

2 × F Buchse

Outputs 

 

1 × F-Stecker Quickfix

Current consumption 

 

16V=/1,5 A

Data interface 

 

1 × RJ 45 

 

SKT 40-2xM 

 

SKT 80-2xM

Ducts 

 

8

Multituner 

4 × DVB-S/S2/T/T2/C 

 

8 × DVB-S/S2/T/T2/C

Inputs 

4 × F Buchse 

 

8 × F Buchse

Outputs 

1 × F-Stecker Quickfix 

 

2 × F-Stecker Quickfix

Current consumption 

16V=/1,5 A 

 

16V=/3 A

Data interface 

1 × RJ 45 

 

2 × RJ 45

 

 

All modules

Input

Frequency range TERR | SAT   100…860 MHz | 950…2150 MHz
Input level TERR | SAT 

 45…85 dBµV | 43...84 dBµV/-65 … -25 dBm

LNB 

voltage 

 13/17 V; 22 kHz on/off; DiSEqC 1.0

Max. 

LNB current (per input)   

250 mA

Symbol rate  

 

1,5…45 MS/s

Error correction 

 

automatisch

Transport stream 

 MPEG-2 ISO/IEC 13818 | MPEG-4 ISO/IEC 14496

Output

Frequency range 

 

114…858 Mhz

Output channels 

 

S2…K69

Modulation 

 

QPSK, QAM 16, 64, 256

FET 

 

2k / 4k mode

FEC 

 

1/2, 3/5, 2/3, 3/4, 4/5, 5/6

Guard Interval 

 

1/4, 1/8, 1/16, 1/32

Norm 

 

CCIR, Australia

Output level 

 

80…100 dBµV

MER  

 

> 39 dB

Ambient temperature range   

-10°C…+50°C

Dimensions approx. 

  72 mm × 218 mm × 129 mm

 

SKT 40-24M 

 

SKT 80-22M

Common Interface 

 

2