Operation instructions | SKF 42-00 | SKF 82-00
Page 8 of 24 AXING-BA_SKF-42-82-00.pdf | Technical improvements, changes in design, printing and other errors reserved. | 2021-12-13
3. Configuration
The device is configured via the graphical user interface of the integrated web interface. To access the user
interface, you need a standard PC/laptop with a network interface and the actual version of the installed web
browser. To connect the network interface of the module to the computer, you need a commercially available
network cable.
The following values are preset ex factory:
IP address:
192.168.0.145
Subnet mask:
255.255.255.0.
The computer and the module must be in the same subnetwork.
è
Change the IP address of your PC/laptop, e.g. to 192.168.0.1, subnet mask 255.255.255.0
è
Connect the PC to the RJ-45 Ethernet port
Control
.
è
Enter the IP address 192.168.0.145 in the address line of your browser.
The login dialogue is displayed.
è
Enter the default password:
Ramsen8262
Click ENTER PASSWORD.
The Frontpage is displayed.
The standard language of the user interface is English. In the header, the the language of the user interface can
be changed. The possibilities are German (DE) and English (EN). The chosen language applies until the end of
the session.
Changing the password:
è
Please change the password immediately after the first commissioning and choose a sufficiently safe
password. Keep this password at a safe place.
è
Menu item: MAINTENANCE > SET NEW PASSWORD.
3.1.
Front page
The relevant information required for the function of the system are shown on the front page. The decisive
thing is the quality of the signals at the INPUT and the utilization of the modulators at the OUTPUT.
Language