Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2020-04-16

Technical improvements, changes in design, printing- and other errors expected.

Technical data:

Type

SES 522-06

Inputs

Number

5

Frequency range

5…862 MHz @ TERR

250…2350 MHz @ SAT

LNB voltage

12 V

Max. LNB current

500 mA per LNB

1000 mA total

Level (AGC)

60… 90 dBµV

Isolation V | H.

30 dB

Subscriber ports

Number

2

Supported standards

EN 50494, EN 50607

Tap loss TERR

17 dB

Frequency range (SAT)

950…2150 MHz

User bands

4

User band frequencies

1331/1382/1433/1484 MHz

Output level SAT (SCR/CSS)

91 dBµV ±2,0 dB

Current consumption from STB (SCR/CSS)

180 mA 

Trunk outputs

Number

5

Through loss TERR

2 dB ±2,0 dB

Through loss SAT

2 dB ±2,0 dB

Connectors

Connector type

F

Return loss

≥ 10 dB

General

Equipotential bonding connection

4 mm²

Operating temperature range 
(acc. to EN 60065)

-20…70°C

Dimensions (W × H × D) appr.

140 x 111 x 63 mm

Weight

0,318 kg

SES 522-06

premium

-line

Single cable multiswitch

 

II

 

(SCR)

Operation instructions

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 

technicians observing the current guidelines. No liability will be assumed 

in the case of faulty installation and commissioning.

 

Before handling the device, disconnect the power supply, otherwise there 

is danger to life. This also applies if you clean the device or work on the 

connections.

 

If a replaceable fuse is available, pull the mains plug before changing 

the fuse. Replace damaged fuses only with standard fuses of the same 

nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms or 

outdoors there is danger of short-circuit (caution: risk of fire) or  

electrocution.

 

To prevent damage to your equipment and to avoid possible peripheral 

damages, mount the device only on flat surfaces. 

 

Choose the location of installation or mounting such that children may 

not play unsupervised near the equipment and its connections. 

 

The location of installation or mounting must allow a safe installation of 

all cables connected. Connected cables must not be damaged or crushed 

by any objects.

 

Absolutely avoid that cables come near any source of heat (e.g.  

radioators, other electrical devices, chimney, etc.).

 

Choose the location of installation or mounting so that under no  

circumstances liquids or objects can get into the equipment (e.g.  

condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 

sources (e. g. radiators. other electrical devices, chimney, etc.). 

 

Devices that are equipped with heat sinks or ventilation slots must under 

no circum-stances be covered or blocked. Also ensure for a generous air 

circulation around the equipment. In this way you avoid possible damage 

to the equipment as well as a risk of fire caused by overheating. 

 

In case of damage, interrupt the power supply immediately.

 

Do not try to repair the device. This device should only be serviced or 

repaired by qualified service personnel. Contact your distributor for more 

information.

 

Do not open the device.

 

For disassembly always pull the mains plug first and disconnect the 

power supply cable from the connected device. 

CE Confirmation Declaration

Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet 
address: 

https://axing.com/en/downloads/ce/

WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of 
as residual waste, it must be disposed of separately.

Отзывы: