background image

Assigning programmes

Every tuner is assigned to a modulator. The programmes of the tuner can only be assigned to the associated modulator.

For example, click on M1.

The program is assigned to modulator 1. The button of the modulator is highlighted in color (a new click on a 
modulator allow the assignment to be canceled. The modulator fades then again).

Click on SAVE CHANGES.

The assignment is saved to the device.

LCN (Logical Channel Numbering)

The LCN function enables channel allocation for the station scan of the TV devices. The TV device must support the LCN 
function.

Different LCN standards can be selected with the drop down menue

 Region

. This standard may vary from area to area.

An LCN can only be entered for programs assigned to a modulator.

Click on the

 LCN

 column for the corresponding program.

Enter the LCN with the keyboard or increase / decrease the LCN with the arrow buttons right of the number.

Enter a own LCN for each desired program.

To erease the LCN, enter 0 in the LCN column.

Click SAVE CHANGES.

The LCNs of the channels are saved.

Содержание MIE 16-00

Страница 1: ...MIE 1600 MIE 3200 MIE 1600 48 MIE 3200 48 IPQAM COFDM ...

Страница 2: ...evice and its connections without supervision The mounting or installation location must allow a safe installation of all connected cables Power supply cables and supply cables must not be damaged or squeezed by any objects Operate the device only on a flat firm surface and protect it against unintentional movements Never expose the device to direct solar irradiation and avoid direct vicinity of h...

Страница 3: ...r 2 12 DVB T output channels Power supply redundand 100 240 VDC MIE 1600 48 Includes 1 module supports SPTS and MPTS also mixed transmodulates max 512 input streams in 16 DVB C or 12 DVB T output channels Power supply 36 60 VDC MIE 3200 48 Includes 2 modules supports SPTS and MPTS also mixed transmodulates max 2 512 input streams in 2 16 DVB C or 2 12 DVB T output channels Power supply 36 60 VDC C...

Страница 4: ... Application examples ...

Страница 5: ...te of the output modulators When a modulator is filled with content and the modulator is not overloaded the corresponding LED lights up green If a modulator is on but not filled without content the corresponding LED flashs If a modulator is overloaded too much content the LED lights up red In case a modulator is turned off the corresponding LED is off Connectors MIE 1600RED MIE 3200RED Connectors ...

Страница 6: ... Note For 19 inch rack mounting there must be at least 5 cm clearance in front of and behind the unit Slide the device into the 19 rack Screw the device with four screws 2 Install the device in compliance with the safety regulations defined by the EN 60728 11 standard Equipotential bonding The device must be connected to the equipotential bonding according to EN 60728 11 Use the equipotential bond...

Страница 7: ...s two modules A and B Each module has its own IPTV address Default IPTV address of module A 192 168 0 146 Default IPTV address of module B 192 168 0 149 Subnet mask 255 255 255 0 The expansion module MIM 16 00 also has its own IPTV address Default IPTV address of the expansion module 192 168 0 149 Subnet mask 255 255 255 0 Connect the IPTV input to an Ethernet switch connected to the IPTV source U...

Страница 8: ...nded by a further hardware module MIM 1600 Disconnect the device from the mains Disassemble the cover plate on the back Insert the module carefully The module noticeably snaps into the contacts Screw the module with the screws of the cover plate Then reconnect the device ...

Страница 9: ... and B Each module has its own IPTV address Default IP address of module A 192 168 0 145 Default IP address of module B 192 168 0 148 Subnet mask 255 255 255 0 The expansion module MIM 1600 also has its own IPTV address Default IP address of the expansion module 192 168 0 148 Subnet mask 255 255 255 0 The computer and the device must be in the same subnetwork The network part of the IP address of ...

Страница 10: ...terface can be changed The chosen language applies until the end of the session To log out click LOG OUT Notes If the browser is closed while you are still logged in an automatic logout occurs 2 5 minutes later If the browser window stays open there is no automatic logout It allows monitoring the installation via the web browser Changing the password Please change the password immediately after th...

Страница 11: ...ay cause image disturbances e g mosaic images The data rates of the programmes are not constant They are dynamically changed by the sender To ensure an undisturbed reception a reserve must absolutely be observed We recommend you to set the maximal fill level to 90 From a fill level of 95 this is indicated in red The number of chosen programmes see 3 4 on page 15 and the configuration of the modula...

Страница 12: ...nitialization starts with PHASE 1 Input streams In Phase 1 the IP address port data rate in Mbps and status of the input streams are displayed in a table Click on a stream Further information such as the program name is displayed You can rescan a stream or delete a stream ...

Страница 13: ...tion Add multiple streams Enter the End IP Streams are created between the IP Address and the End IP in the example 239 0 0 1 239 0 0 2 and 239 0 0 3 Options Activate the option Select all to modulator and select a modulator All newly added streams are assigned to this modulator Activate the option Erease all current streams IMPORTANT All previous input streams will be deleted Only the newly creat...

Страница 14: ...rams The Transport stream IDs the Network ID and the network name can be changed Different LCN standards can be selected with the drop down menue Region DVB C If DVB C is selected as the output modulation DVB T If DVB T is selected as the output modulation ...

Страница 15: ... Channel Numbering The LCN function enables channel allocation for the station scan of the TV devices The TV device must support the LCN function Different LCN standards can be selected with the drop down menue Region This standard may vary from area to area An LCN can only be entered for programs assigned to a modulator Click on the LCN column for the corresponding program Enter the LCN with the ...

Страница 16: ...he entered program name appears in the channel list of the TV devices PID Filtering Individual packages can be filtered out of the transport stream Click on one of the programs The table with the Packeges opens This contains the name the PID and a check mark By default all PIDs are initially selected Remove the check mark if desired The packet is no longer transmitted in the transport stream ...

Страница 17: ...g France end users are asked to start a channel search If it comes to the case that one or more stations are weak to receive then the NIT changes frequently and the end users are always unnecessarily prompted to start a channel search In this case the NIT version can be frozen recommended for use in France Under NIT version select Fixed Enter a version between 1 and 31 Note If the station list rea...

Страница 18: ...t to any output channel between S2 and CH 87 No output channel can be assigned several times DVB C constellation With DVB C modulation you can choose between 32QAM 64QAM 128QAM and 256QAM 256QAM enables the highest data transmission rate but it also requires the best network quality DVB C symbol rate The DVB C symbol rate can be freely set between 1000 and 7500 The standard value is 6900 Some netw...

Страница 19: ...channel depends on the selected channel bandwidth 7 or 8 MHz the set symbol rate and the DVB C modulation QAM32 64 128 256 of the modulator If the displayed data rate exceeds 95 there are different possibilities to change it Change to a channel with a bandwidth of 8 MHz if a 7 MHz channel was selected previously Set DVB C modulation to a larger value for example change from QAM 64 to QAM 128 Reduc...

Страница 20: ...vel with a setting of 0 dB Norm In this selection field you can set the norm for the output channel spacing Note Changing the norm works now according to following rules CCIR Australia all modulators forced to 7MHz Australia CCIR all modulators forced to 8MHz however with following exception low channels S2 S20 are 7MHz only so those remain in 7MHz Output channel The first modulator can be set to ...

Страница 21: ...cy FEC 1 2 small data rate strong protection against errors FEC 7 8 high data rate weak protection against errors DVB T bandwidth The DVB T standard plans a broadcast on 6 7 or 8 MHz channels A bigger bandwidth means that more data can be transmitted on a single channel In the CCIR channel spacing the lower channels C5 S20 have a provided bandwidth of 7 MHz The other channels have a bandwidth of 8...

Страница 22: ...B T channel depends furthermore on the chosen channel bandwidth 7 or 8 MHz on the set error correction rate FEC and the modulation rate QPSK 16QAM 64QAM of the modulator If the displayed data rate exceeds 90 there are different possibilities to change it Change to a channel with a bandwidth of 8 MHz if a 7 MHz channel was selected previously Raise the modulation rate to 64QAM QPSK corresponds to t...

Страница 23: ...he menu entry MAINTENANCE enables software updates changing the IP address changing the password restarting the device and much more Under Current Settings you will find the following information Firmware version Displays the firmware version and the output modulation type Software version Displays the version of the interface Serial number of the device Processor temperature must remain below 90 ...

Страница 24: ... and overview Download You can find software updates by entering the article in the search field at www axing com Download the current version of the file to your computer and unpack it Update New software for the graphical user interface can be installed under SOFTWARE FILE Click under SOFTWARE FILE on Browse Browse for the file on your computer Click on UPDATE The file will be uploaded to the de...

Страница 25: ...T Select a Modulation Standard Click SAVE REBOOT The changing of the modulation standard begins the remaining time ist shown as a countdown The device will be automatically rebooted the enter password dialog will be displayed Enter the password again Check especially the modulator settings and their fill level ...

Страница 26: ...s Use dynamic IP address to connect the device to a network with a DHCP server Static IP adress Use a static IP address to connect the device to a network with a fixed IP address The IP address netmask and the gateway can be changed here In addition DNS server 1 and DNS server 2 can be entered Click SAVE REBOOT to confirm and save the changes When the changes are saved the device will reboot autom...

Страница 27: ... CHANGES to confirm and save the changes When the changes are saved the frontpage will be shown Rebooting Under REBOOT THE SYSTEM the device can be rebooted Click on REBOOT After rebooting the password must be entered again Erasing service data In the section ERASE SERVICE DATA you can erase the settings of phase 1 and phase 2 The input streams and the selection of programs are deleted Click on er...

Страница 28: ...at the download folder on your computer Note Password and IP adress will not be saved Upload Initialization Data In the section UPLOAD SYSTEM INITILIZATION DATA FROM FILE you can upload the initiaization data from a file to the modul After an update initialization data saved with older software versions can be loaded into the device with a newer Software version Initialization data saved with a ne...

Страница 29: ... device In the State field select Enabled Activate if required the option AXING support allowed In the field Location enter a name for the location of the device This name will appear later in the SMARTPortal to help you identify the device In the field Email address enter the e mail address with which you are registered at SMARTPortal In the field User key enter the user key that you received whe...

Страница 30: ...ce MIB AXING MIB txt For example 192 168 0 145 MIB AXING MIB txt SNMP Agent Set the Agent switch to ON to use GET REQUEST and GETNEXT REQUEST The Agent Port is by default 161 if necessary enter another port In the SNMP Version field select version SNMPv1 or SNMPv2c SNMPv2c is recommended The Community Name the SNMP password is public by default if necessary enter a different community name Traps T...

Страница 31: ...AM and starts again after a restart In the status log for example the lock in time and the frequencies of the tuners are stored Select System log The system log is written to the flash memory so it is still available after a restart In the system log for example the boot time and hardware defects are stored ...

Страница 32: ...imulcrypt Simulcrypt license needed to activate Network interface used for all simulcrypt related network traffic By default Ethernet port labeled as CAS is used IP address of this port must be configured for EMMG CAS server EMMG Listening Port TCP port configured in EMMG CAS server to connect the headend 2 CAS list Add here all connected CA Systems Each CA System is identified by two IDs the CA_s...

Страница 33: ...crambling Policy Option values All ECMGs Services connected to this SCG are scrambled only if all ECMGs are connected ok Any ECMG Services connected to this SCG are scrambled as long as at least one ECMG is connected Always Services are scrambled always If all ECMG connections are lost no one is able to descramble Fallback Fallback rule in case Scrambling Policy defined above is not fulfilled Opti...

Страница 34: ... ID optional ECM_channel_id used when communicating with ECMG Some ECMGs require a specific value for this ID info from CAS supplier If left empty device uses some unused random ID Remote IP IP address of the ECMG server to connect to Port Port of the ECMG server to connect to CAS CA system of this ECMG name from the CAS table Status ECMG server connection status ...

Страница 35: ... ECM_id used when communicating with ECMG Some ECMGs may require a specific value for this info from CAS supplier If left empty some random ID is used SCG Scrambling Control Group whose control words are transmitted by this ECM value from SCG table Access Criteria Arbitrary binary data transmitted to the ECMG Typically used to tell the ECMG which clients should be able to decode the ECMs Format an...

Страница 36: ...s cell can be left empty But if IP address is entered only connections from this address are allowed CAS CA System from the CAS table Client ID optional The value EMMG uses to identify itself info from CAS supplier Often Super_CAS_id is used as client_id so can be left empty and device automatically uses Super_CAS_id of the selected CAS EMM List table EMM Generator Name from EMM Generator table Da...

Страница 37: ... shows all configured SCGs select one By default all video and audio PIDs for the service are selected for the scrambling Select unselect individual PIDs at Scramble column to overwrite the defaults Press Save changes once ready After saving the changes encryption status column shows scrambling status for each service selected for scrambling ...

Страница 38: ... please check status columns at ECMG and ECM tables 3 ECM table status Status of each ECM stream Re check access criteria value if status is red 4 ECMG table status Server connection status The least important item but indicates some network setup problem if status color is red Check that e g network cable is properly connected to the device All the other status items stay red until ECMG status be...

Страница 39: ...ut level 80 105 dBµV DVB C 77 102 dBµV DVB T Output connector 1 F 2 F Output test port 30 dB Output modulation Compliance DVB C J 83 Annex A C DVB T Modulation type QAM32 QAM64 QAM128 QAM256 DVB C QPSK QAM16 QAM64 DVB T Output transmission symbol rate 1 7 5 Mbps MER 40 dB DVB C 36 dB DVB T FFT DVB T 2k mode FEC DVB T 1 2 2 3 3 4 5 6 7 8 Common Configuration interface CAS interface 1 RJ 45 IEEE 802...