Product description:

The EOC 30-01 Master and the EOC 30-21 Dual Master use the G.hn standard 
to build an Ethernet-over-coax network with the EOC Endpoints via the coaxial 
cables of the house installation. The EOC Master is connected to the internet 
modem of the telephone or cable operator.
The EOC devices use the frequency range of 5 ... 204 MHz ex works. All 
components in the coaxial cable network should be suitable for return path in 
this frequency range to enable the full data rate.
If the return path range in an installation is only 5 ... 65 MHz, then the return 
path range used by the EOC devices can be limited to 5 ... 65 MHz (Configure 
a notch filter for all devices and install a TZU 198-64 low-pass filter on the 
EoC+RF port of the master and on all G.hn ports of the endpoints). This results 
in a limited data rate.

 

The device may only be used in a CATV network if the forward path frequency 
range of the CATV network starts from 258 MHz or the return path range used 
by the EOC devices is limited to 5 ... 65 MHz.

Scope of delivery:

 

9

EOC 30-01 or EOC 30-21

 

9

CAT5 ethernet cable 

 

Connects from LAN port to Internet modem

 

9

12 VDC power adapter for power supply

 

9

Quickstart guide

Note:

 You can call up the detailed operation instructions for download by 

entering the article in the search field at www.axing.com.

Ports on the rear panel:

A

B

C

D

E

F

Label

Type

Function

A DC IN 12V

DC

Connect to the power adapter plug

B

LAN2 (PoE) 

RJ-45

100/1000 Base-T Gigabit Ethernet port, built-in 
PoE PD function.

C LAN1

RJ-45 100/1000 Base-T Gigabit Ethernet port

D Reset

Reset button

E

EoC+RF

F

EOC port

F

RF

F

Do not use

LED Indicators:

Label

Status

ON

Flashing

Power

Powered by DC12V

N/A

LAN1

Green = LAN1 port is active

Data traffic active

Orange = LAN1 = 1Gbps.

LAN2

Green = LAN1 port is active

Data traffic active

Orange = LAN1 = 1Gbps.

Link/Act

EoC+RF port is active

Data traffic active

Diagnosis

EOC Master is diagnosing EOC 
connection toward/from EP

Not 
labelled

Forcing to default settings via reset 
button.

Bootloader mode

Configuration:

The device is configured via the graphical user interface of the integrated 
web interface. To access the user interface, you need a standard PC/laptop 
with a network interface and the actual version of the installed web 
browser.
The factory default IP address is 192.168.1.1 and the default subnet mask is 
255.255.255.0. To access the EOC with default IP, your PC should be within 
the same IPv4 network. 
The EOC Master will prompt you a window for password authorization. The 
both factory default username and password is ‘admin’.

 

After the first log-in, the password should be changed.

Note:

 Under NMU Configuration, Quality of Service (QoS) the option Traffic 

Awareness should set to On. This achieves optimized data traffic.

Hardware connections:

 

Select a convenient location for the EOC near the internet modem to which 
it will be connected. The device should be kept away from excessive heat.

 

Please make sure the coaxial network is well grounded. 

 

Use a coaxial cable to connect the EOC+RF port to the feeding in point of 
the coax network (splitter, combiner, terrestrial input of a multiswitch etc.). 

 

Connect the LAN1 or LAN2 port to the internet modem. 

Power Supply:

The DC switch on the side has two positions:

DC IN:

 The EOC Master runs in local power mode.

 

Connect the power adapter to the DC IN 12V port and connect it to a wall 
outlet.

LINE: 

The EOC Master runs in line power mode

 

Powering EOC Master via the coaxial cable connected to port ‘RF+Data’ 
or port ‘RF’ from coax is necessary (typical 60 VAC input (range 48V~90V, 
50/60 Hz AC).

 

Alternatively powering EOC Master via the port LAN2 (PoE = Power over 
Ethernet acc. to IEEE 802.3af or 802.3at, it supports mode A and B).

Reset or settings to factory default:

 

While EOC Master is on, press the reset button for 1 second.  
The EOC Master will reboot. 

 

Press the reset button for 5 seconds until the unlabelled LEDs next to the 
diagnosis LED light up. 
All settings are set to factory default (for example, the IP address will be set 
to 192.168.1.1).

 

Press the reset button for lasting 10 seconds until the unTabd LEDs and the 
diagnosis LED will light up. 

All configured values of the EOC Master and the connected EOC 30-
0x are reset to factory settings.

Master-Endpoint

SMART

TV

SMART

TV

Existing coaxial cable

Router 
(xDSL | xPON | LTE )

Содержание EOC 30-01

Страница 1: ...to Datenrate PHY 1800 Mbps Verschlüsselung AES 128 Bit Max Anzahl Geräte im EoC Netzwerk 16 32 Schnittstellen Ethernet Anschlüsse LAN 2 RJ 45 Ethernet Standards IEEE 802 3u 100BaseT Fast Ethernet IEEE 802 3ab 1000BaseT Gigabit Ethernet IEEE 802 3az Energy Efficiency Ethernet Allgemein Betriebsspannung 12 VDC Leistungsaufnahme 5 W 7 W Betriebsspannung über Koax 60 VAC 20 Betriebsspannung über LAN P...

Страница 2: ...thernet Kabel um den LAN1 oder LAN2 Anschluß mit dem Internet Modem zu verbinden Spannungsversorgung Der Schalter auf der Seite des EOC Master hat zwei Positionen DC IN Das EOC Master läuft mit lokaler Versorgung Verbinden Sie das Steckernetzteil mit dem DC IN 12V Anschluss und stecken Sie das Steckernetzteil in eine Steckdose LINE Das EOC Master läuft mit Fernspeisung Versorgen Sie das EOC Master...

Страница 3: ...a rate PHY 1800 Mbps Encryption AES 128 Bit Max number of devices in EoC network 16 32 Interfaces Ethernet connectors LAN 2 RJ 45 Ethernet standards IEEE 802 3u 100BaseT Fast Ethernet IEEE 802 3ab 1000BaseT Gigabit Ethernet IEEE 802 3az Energy Efficiency Ethernet General Operating voltage 12 VDC Power consumption 5 W 7 W Operating voltage over Coax 60 VAC 20 Operating voltage over LAN PoE 37 57 V ...

Страница 4: ...iguration The device is configured via the graphical user interface of the integrated web interface To access the user interface you need a standard PC laptop with a network interface and the actual version of the installed web browser The factory default IP address is 192 168 1 1 and the default subnet mask is 255 255 255 0 To access the EOC with default IP your PC should be within the same IPv4 ...

Отзывы: