Feeding in of IP data in a CATV distribution structure:
Example 3: The feeding of the IP signal is performed via
the return channel capable antenna socket
.
If the
IP-data are fed via the antenna socket, a high-pass filter TZU 19-65 must be installed in the coaxial supply line
(amplifier output).
Example 4: IP data feeding for exactly one antenna socket: The feeding of the IP signal is performed
via the
EoC combiner TZU 40-03
. The integrated high pass of 85-1006 MHz prevents the transmission of the IP
signal in the CATV network. The antenna socket BSD 963-13 is equipped with a high pass filter on the trunk.
The IP signal will not be transferred to the following antenna sockets.
Feed in of IP data in a headend system:
Example 5: The feeding of the IP signal is performed
via the EoC combiner TZU 40-03
. The combiner TZU
40-03 has an integrated high pass of 85-1006 MHz. The high pass prevents the transmission of the IP signals
to the head end.