background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2020-04-03

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 

technicians observing the current guidelines. No liability will be assumed 

in the case of faulty installation and commissioning.

 

Before handling the device, disconnect the power supply, otherwise there 

is danger to life. This also applies if you clean the device or work on the 

connections.

 

Providing that a serviceable fuse exists, the power plug must be pulled 

out before changing the fuse. Defective fuses may only be replaced with 

standard compliant fuses that have the same nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms or 

outdoors there is danger of short-circuit (caution: risk of fire) or  

electrocution.

 

To prevent damage to your equipment and to avoid possible peripheral 

damages, mount the device only on flat surfaces. 

 

Choose the location of installation or mounting such that children may 

not play unsupervised near the equipment and its connections. 

 

The location of installation or mounting must allow a safe installation of 

all cables connected. Connected cables must not be damaged or crushed 

by any objects.

 

Absolutely avoid that cables come near any source of heat (e.g.  

radioators, other electrical devices, chimney, etc.).

 

Choose the location of installation or mounting so that under no  

circumstances liquids or objects can get into the equipment (e.g.  

condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 

sources (e. g. radiators. other electrical devices, chimney, etc.). 

 

Devices that are equipped with heat sinks or ventilation slots must under 

no circum-stances be covered or blocked. Also ensure for a generous air 

circulation around the equipment. In this way you avoid possible damage 

to the equipment as well as a risk of fire caused by overheating. 

 

In case of damage, interrupt the power supply immediately.

 

Do not try to repair the device. This device should only be serviced or 

repaired by qualified service personnel. Contact your distributor for more 

information.

 

Do not open the device.

 

For disassembly always pull the mains plug first and disconnect the 

power supply cable from the connected device. 

SPU 58-06 | SPU 512-06 
SPU 516-06 | SPU 524-06 
SPU 532-06

basic

-line

Multiswitches / 
Cascade units

Operation instructions

Technical data:

CE Confirmation Declaration

Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU. 
The full text of the EU declaration of conformity is available at the following internet 
address: 

https://axing.com/en/downloads/ce/

WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of 
as residual waste, it must be disposed of separately.

Type

SPU 58-06

SPU 512-06

SPU 516-06

SPU 524-06

SPU 532-06

Inputs

Number

5

Frequency range

5…862 MHz | 950…2400 MHz

Max.

 LNB current

1500 mA

Isolation 

V | H.

>30 dB

Isolation 

TERR | SA

30 dB

Subscriber ports

Number

8

12

16

24

32

Switch commands

13/18 

V,

 0/22 kHz

Tap 

loss TERR

23 dB ±2 dB

27 dB ±3 dB

27 dB ±3 dB

33 dB ±3 dB

33 dB ±3 dB

Tap loss SA

T

-1...-3 dB ±2 dB

-1...-2 dB ±2 dB

-1...-2 dB ±2 dB

2...-1 dB ±2 dB

2...-1 dB ±2 dB

Max.

 output level  SA

T (3rd or

-

der SA

T EN 50083

-3 35dB KMA,

 2 sender test method)

102 dBµV

Current consumption per port (without LNB supply)

< 35 mA

Trunk outputs

Number

5

Through 

loss TERR

2 dB ±1 dB

2…3 dB ±1 dB

2…3 dB ±1 dB

2 dB ±2 dB

2 dB ±2 dB

Through loss SA

T

2 dB ±1 dB

2…4 dB ±1 dB 

2…4 dB ±1 dB 

2…6 dB ±2 dB

2…6 dB ±2 dB

Connector

s

Connector type

F

Gener

al

Equipotential bonding connection

4 mm²

Operating temperature range (acc.

 to EN 60065)

-20…+50°C

Dimensions (W × H × D) appr

.

112 x 137 x 63 mm

150 x 137 x 63 mm

150 x 137 x 63 mm

240 x 137 x 63 mm

240 x 137 x 63 mm

Protection class

IP 20