background image

 

10 

               CAL-HYPO SYSTEM 

                       LIMITED WARRANTY 

 

 

Axiall, a Westlake Company ("Axiall") warrants (subject to the below conditions) only its title to this water treatment 
system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of 
eighteen (18) months from its original shipment date.  
 
THIS IS THE ONLY REPRESENTATION OR EXPRESS WARRANTY THAT AXIALL MAKES AND ALL OTHER 
EXPRESS WARRANTIES UNDER STATUTE OR ARISING OTHERWISE IN LAW FROM A COURSE OF DEALING OR 
USAGE OF TRADE WITH RESPECT TO THE SYSTEM ARE DISCLAIMED. ANY IMPLIED WARRANTIES EXISTING 
AS A MATTER OF LAW SHALL NOT EXCEED THE DURATION OF THIS LIMITED WARRANTY. IN THE EVENT THE 
SYSTEM FAILS TO CONFORM TO THIS WARRANTY, AXIALL'S EXCLUSIVE OBLIGATION AND YOUR EXCLUSIVE 
REMEDY SHALL BE LIMITED TO, AT AXIALL'S OPTION, THE FURNISHING OF NEEDED REPLACEMENT PARTS 
OR THE FURNISHING OF A NEW SYSTEM (BUT THIS DOES NOT INCLUDE INSTALLATION OR THE COSTS FOR 
INSTALLATION). EXCEPT AS PROVIDED IN THE IMMEDIATELY PRECEDING SENTENCE, IN NO EVENT WILL 
AXIALL BE LIABLE UNDER ANY THEORY OF RECOVERY (WHETHER BASED ON NEGLIGENCE OF ANY KIND, 
STRICT LIABILITY OR TORT) FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, OR 
CONSEQUENTIAL DAMAGES IN ANY WAY RELATED TO ANY USE MADE OF THE SYSTEM.  
 
Warranty Conditions. This Limited Warranty shall apply and be effective only if: (i) the System is installed and operated 
and maintained in accordance with this manual and the instructions accompanying the System; (ii) you, at your cost, 
promptly return the System or defective part to such location as may be specified by Axiall; and, (iii) only Axiall

’s Accu-

Tab® SI calcium hypochlorite tablets are used in the System. If any of these conditions are not met, this Limited Warranty 
will not apply and you acknowledge and agree that your purchase of the System will be on an "AS-IS" basis without any 
warranty of any kind whatsoever having been provided by Axiall.  
 
You assume all responsibility and risk and liability arising from: (i) the unloading, installation, storage, handling and use of 
the System, including use thereof alone or in combination with other materials; (ii) the improper functioning or failure of 
unloading, installation, transportation or storage equipment you use, whether furnished or recommended by Axiall or not; 
and, (iii) the failure to comply with laws, rules and regulations governing storage, unloading, installation, handling, and use 
of the System. You will indemnify, hold harmless, and defend Axiall from and against any claim, suit, damage, cost, 
expense, fine, liability, or cause of action whatsoever, including reasonable attorney fees, on account of relating to, or 
arising out of the use, possession, installation or resale of the System.  
 
This Limited Warranty gives you specific rights, and you also may have other rights, which vary from jurisdiction to 
jurisdiction. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the 
above limitations or exclusions may not apply to you. Some jurisdictions do not allow limitations on how long an implied 
warranty lasts, so the above limitation may not apply to you. 

 

Содержание Accu-Tab 2300

Страница 1: ...erating Instructions Rev 02 10 21 DANGER DO NOT MIX CHEMICALS The Accu Tab chlorinator is designed for use with Axiall approved tablets only Do not use Cal Hypo tablets with stabilized chlorine or bro...

Страница 2: ...This results in a constant and predictable rate of chlorine delivery Additional water is supplied to the solution tank with float level control to assure the pump does not run dry A high level switch...

Страница 3: ...the H O A switch to HAND Solenoid valve will open feeding water to the system 9 Open the pump prime line valve to allow water to prime the pump 10 Once the water level in the tank clears the low level...

Страница 4: ...4...

Страница 5: ...5...

Страница 6: ...6...

Страница 7: ...7...

Страница 8: ...needed D Cleaning the chlorination system Over time and depending on the water chemical characteristics some calcium scale may build up in the system Following procedure to clean 1 Prepare 2 gallons o...

Страница 9: ...verify that it is the check valve 2 Disassemble the check valve to check for debris or scale 3 If scale is present clean with a dilute acid solution 4 Reassemble the check valve and open the isolation...

Страница 10: ...companying the System ii you at your cost promptly return the System or defective part to such location as may be specified by Axiall and iii only Axiall s Accu Tab SI calcium hypochlorite tablets are...