background image

4.650B_UK - 5

Ref. 4.650B_UK - 2015-01-14.  www.axel-larsson.se

MANUAL 

BALL SECTOR VALVE AL 74-KS / KSP

j) Mount the nut (12) slightly with fingers. Fasten the flange (1A) into  
   a vice and tighten nut (12) hard with a box-spanner.
k) Turn ball sector between open and closed a few times to ensure  
    that the necessary torque is normal, approx 5 Nm, during the hole  
    stroke. 

DN 40-50 (1½"-2")

(reassembly is done in reverse order)

Sliding ring (13A) can only be mounted with the tool shown in fig 2. 
When O-ring (13) has been placed in its groove on the shaft (5) and 
drive shaft (6) and then pushed into the body great care must be 
taken not to damage the o-ring. Fig. 3 shows a suitable method and 
dimensions on a tool that will protect the O-ring (13) and Rulon 
bearing (9) when assembling. 
Check that the locking ring (4A) is undamaged and kept in some 
tension in its groove after reassembly. Change ring if necessary.

DN 80 - 300 (3"-12")

(reassembly is done in reverse order)

Sliding ring (13A) can only be mounted with the tool shown in fig 2. 
Carefully push the bearing sleeve (4) with the O-ring (14). When the 
O-ring passes the drilled hole for the stop screw (12) it might be 
pressed into the hole with risk for damage. Check that the hole is 
free from sharp edges or burrs. When the O-ring passes the hole it 
can be pushed back from out side with a blunt end pin. 
Check that the locking ring (4A) is undamaged and kept in some 
tension in its groove after reassembly. Change ring if necessary.

After reassembly 

Pressure test the valve with air from the valves outlet side and with 
the valve closed. The valve immersed in water or with leakage spray 
shall be bubble tight over shaft seals and seat. I small bubbles can be 
detected around the shafts it can be enough to actuate the valve a 
few times allowing the O-rings to find its correct position. If the valve 
still leaks the o-ring has been damaged and must be changed. Valves 
with PTFE-seat shall be bubble tight in both directions. Valves with 
stellited seat will never be bubble tight. These valves can be tested 
with water. Max leakage for a new valve is 0,01% of the valves Cv/
Kvs-value. 

Mounting actuator on the 

valve - IMPORTANT!

a) Avoid to axially move the ball sector in the valve body. Never ham 
    mer on the drive shaft end when mounting the actuator.
b) The ball sector must not be turned more than 900 necessary to  
    operate the valve from closed to open position. If the ball sector  
    accidentally has been turned out of the range, the screws on the  
    inlet cover must be loosened and the contact pressure between  
    ball sector and seat ring reduced to zero before the ball sector is  
    returned to right position.
c) When the actuator is properly mounted and adjusted it shall turn  
    the ball sector 900 between open and closed. Closed position of  
    the ball sector sealing surface shall for optimum tightness be such  
    that the seat ring is located in the middle of the sealing surface as  
    indicated in fig. 4.

Fig. 2 - Tool for mounting gliding ring and O-ring.

DN

Dy

Dj

L1

L2

L3

150-200

32

26

100

40

36

250

38

32

110

45

42

300

50

40

130

60

55

Отзывы: