Axcera-430B Type Acceptance Report
Test Report
February 2004
4-9
4.4 Conducted Spurious Emissions
Using the test setup shown in Figure 4.1, the spectrum outside of the specified channel
was observed and the data was recorded on all products above the 70-dB noise floor of
the spectrum analyzer. This data is shown in Table 4-6 and is presented as graphs in
Figures 4-9 and 4-10.
Table 4-6. Products Above the 70-dB Noise Floor of the Spectrum Analyzer
FREQUENCY (MHz)
SOURCE
PEAK LEVEL
OBSERVED (dB)
266.75
Image Visual Carrier
None observed
262.25
Image Aural Carrier
None observed
221.00
Local Oscillator
None observed
166.25
-9-MHz Product
None observed
170.75
-4.5-MHz Product
-69
179.75
Aural Carrier
-10
175.25
Visual Carrier
0
182.45
+7.2-MHz Product
None observed
186.05
+10.8-MHz Product
None observed
184.25
+9-MHz Product
None observed
183.33
+8.08-MHz Product
None observed
180.67
+5.42-MHz Product
-60
171.67
-3.58-MHz Product
None observed
359.50
Second Harmonic -Aural Carrier
None observed
350.50
Second Harmonic -Visual
Carrier
None observed
539.25
Third Harmonic -Aural Carrier
None observed
525.75
Third Harmonic -Visual Carrier
None observed
Figure 4-9. Products Above the 70-dB Noise Floor of the Spectrum
Analyzer (1 of 2)