2.1 Introduction and Features 

The AWS  M  series  wind  power  generation  controller  is  a  controller  which  integrates  MPPT 

control  and  charge  and  discharge  control. The  power  curve  can  be  set  by  setting  the  wind  turbine 

voltage and current, which allows the wind turbine to operate within its best power output all the times. 

(All AWS wind controller solar with AWS Wind turbines are preset, do not alter these setings) 

 

Features: 

 

Can be applied to grid-tied system, off-grid system and grid-tied energy storage system. Charge 

function is optional.   

 

MPPT tracking 

 

Protection functions. 

 

Solar PV integregrsation. 

 

RS232/RS485/RJ45/GPRS/Bluetooth/Zigbee optional. (It can be monitored by app for those with 

GPRS/Bluetooth/RJ45 connection) 

Содержание M Series

Страница 1: ...V1 3 AWS MSeries AWS Wind Turbine Controller with MPPT User Manual Model WW15 24 48 ...

Страница 2: ...re 3 3 Product Installation 5 3 1 Installation Notes 5 3 2 Installation and Wiring 6 3 2 1 Installation Steps 6 3 2 2 Installation Steps 7 3 2 3 Electrical Connection 8 4 Operation Interface Introduction 10 4 1 LCD Display 10 4 2 LCD Information Define 11 5 Trouble Shooting 11 6 Technical Parameters 12 7 Warranty 20 ...

Страница 3: ...d Do not open or dismantle any parts of the controller other than the required cable termination cover where fitted Disconnect the AC input and DC output from controller before working on or maintain the controller Do not work on the controller within 5 minutes of de energization The controller is designed for indoor use only Maintain ventilation as detailed in this manual Install on noncombustibl...

Страница 4: ...lows the wind turbine to operate within its best power output all the times All AWS wind controller solar with AWS Wind turbines are preset do not alter these setings Features Can be applied to grid tied system off grid system and grid tied energy storage system Charge function is optional MPPT tracking Protection functions Solar PV integregrsation RS232 RS485 RJ45 GPRS Bluetooth Zigbee optional I...

Страница 5: ...V1 3 3 2 2 Product Structure Chart1 Product Overview 1 3kW ...

Страница 6: ...V1 3 4 Chart2 Product Overview 5 10kW Battery terminal Manual brake switch Dump load terminal Browse button Wind turbine terminal LCD display Communication device port Unload indicator light ...

Страница 7: ...ondensing 3 Altitude should not be more than 4000m 1000 m derating according to the GB T3859 2 regulations 4 Not to be installed in direct sunlight sun exposure rain humidity acid fog and dust 5 Ensure the correct battery voltage and polarity is connected to the controller 6 The controller can only be connected to a wind turbine and PV within an the rated Voltage current and power characteristics ...

Страница 8: ...V1 3 6 3 2 Installation and Wiring 3 2 1 Installation Steps Chart 4 Installation Overview ...

Страница 9: ...V1 3 7 3 2 2 Installation Steps Chart5 Installation Steps ...

Страница 10: ...V1 3 8 3 2 3 Electrical Connection 1 3kW ...

Страница 11: ...by the terminal which marks BATTERY do not reversed the connection of positive and negative terminals 3 Connect the wind turbine output to the WIND INPUT terminal on the controller in any order Insure a wind brake switch is installed at the tower and the brake is activated prior to connection 4 Check all the connection to make sure they are connected rightly and tightly ...

Страница 12: ... Operation Interface Introduction 4 1 LCD Display After the power is connected the screen is in a browsing status It shows battery voltage and can be changed to the following information by press related buttons ...

Страница 13: ...t for another 5s to recover charging status Dump load indicator light Red light is on means the machine is on unload status or brake status The light is off when it works normally 5 Trouble Shooting Fault Type Description Possible reasons and solutions No display on LCD The connection between the battery and the controller is not tight Check the wiring and reconnect it DC breaker is not on between...

Страница 14: ...t Wind Turbine Input Rated input power 1kW Rated input voltage 56Vdc Input voltage range 0 64Vdc Start charge voltage 12Vdc factory default 8Vdc 64Vdc settable Rated input current 21Adc Brake by hand Keep press the button for 5s to unload completely and then recover by hand Switch ON the brake switch Brake by over current 25A factory default 0 25A settable unload completely when reached the set cu...

Страница 15: ...splay information DC output voltage wind turbine voltage current power For those with charge control function Battery voltage is showed as well Monitoring mode optional RS232 RS485 RJ45 GPRS Bluetooth Zigbee Monitoring Contents Real time display DC output voltage wind turbine voltage current power For those with charge control function Battery voltage is showed as well Parameter setting Output ove...

Страница 16: ...c 320Vdc settable Rated input current 42A 9A Brake by hand Keep press the button for 5s to unload completely and then recover by hand Switch ON the brake switch Brake by over current 50A factory default 0 50A settable Unload completely when reached the set current and recover automatically after working 10mins 10Adc factory default 0 10A settable Unload completely when reached the set current and ...

Страница 17: ... voltage Max Output current 42A General Parameters Rectifier mode Uncontrolled rectifier Display mode LCD Display information DC output voltage wind turbine voltage current power For those with charge control function Battery voltage is showed as well Monitoring mode optional RS232 RS485 RJ45 GPRS Bluetooth Zigbee Monitoring Contents Real time display DC output voltage wind turbine voltage current...

Страница 18: ...cover by hand Switch ON the brake switch Brake by over current 15Adc factory default 0 15A settable Unload completely when reached the set current and recover automatically after working 10mins 30A factory default 0 30A settable Unload completely when reached the set current and recover automatically after working 10mins 15Adc factory default 0 15A settable Unload completely when reached the set c...

Страница 19: ...dc factory default 44Vdc 64Vdc settable 140Vdc factory default 110Vdc 160Vdc settable 280Vdc factory default 220Vdc 320Vdc settable Complete unload voltage 60Vdc factory default add 4V to the start unload voltage 150Vdc factory default add 10V to the start unload voltage 300Vdc factory default add 20V to the start unload voltage Max Output current 63A 25A 13A General Parameters Rectifier mode Unco...

Страница 20: ...ension W H D 400 390 210mm Dump load net weight 12kg Note Part of parameters can be adjusted according to customer s specific demand 5 10kW Model WW50 48 240 WW50 120 240 WW50 240 240 WW100 240 240 Type Buck Boost Wind Turbine Input Rated input power 5kW 10kW Rated input voltage 280Vdc Input voltage range 0 320Vdc Start charge voltage 60Vdc factory default 40Vdc 320Vdc settable Rated input current...

Страница 21: ...peed optional 500r min factory default 0 1000r min settable Unload completely when reached the set rotational speed and recover automatically after working 10mins Charge Parameters optional Rated battery voltage 48Vdc 120Vdc 240Vdc 240Vdc Temperature compensation function optional 3mV 2V Output Parameters Rated output voltage 48Vdc 120Vdc 240Vdc 240Vdc Start unload voltage 56Vdc factory default 44...

Страница 22: ...ry voltage is showed as well Parameter setting Output overvoltage point wind turbine over current point wind turbine start voltage and wind turbine manual brake button Lightning protection YES Conversion efficiency 95 Static loss 8W 6W 8W Ambient temperature 20 40 Humidity 0 90 No condensing Noise 65dB Cooling mode Forced air cooling Installation mode Wall mounted Cover protection class IP42 Produ...