background image

17 

FEET 

METER 

OUTPUT POWER 

1-500ft 

0-150m 

100% 

500-1,000ft 

150-300m 

97% 

1,000-2,000ft 

300-600m 

94%

 

2,000-3,000ft 

600-900m 

91% 

3,000-4,000ft 

900-1,200m 

88% 

4,000-5,000ft 

1,200-1,500m 

85% 

5,000-6,000ft 

1,500-1,800m 

82% 

6,000-7,000ft 

1,800-2,100m 

79% 

7,000-8,000ft 

2,100-2,400m 

76% 

8,000-9,000ft 

2,400-2,700m 

73% 

9,000-10,000ft 

2,700-3,000m 

70% 

 

If replacement is necessary, only use parts specified by Australian Wind and Solar. Use other parts 
could cause accidents or malfunction. 

When strong winds blow, tree branches and other objects may make contact with and damage the 
wind turbine, its support pole, or its wiring. Continued use of the wind turbine when it is damaged 
may cause electric shock, a serious accident, or cause the turbine to cease functioning. Inspect all 
parts of the wind turbine after periods of strong wind. 

Do not place the wind generator body upside down or inclined during installation or maintenance. 
Water (rain, snow) can leak inside from the joint gap of the body and may cause damage to the tur-
bine. When the body is upside down or inclined and have a possibility of getting wet, put a cover over 
the body to avoid water. 

Содержание AWS2000

Страница 1: ...Your best solution for all your power needs www australianwindandsolar com AUSTRALIAN WIND AND SOLAR AWS2000 WIND TURBINE INSTRUCTION MANUAL...

Страница 2: ...to the wind genera tor to the battery 7 3 D P D T Double pole double throw blade switch 7 4 Connecting the wind generator output cable extension 7 5 Connection example 7 6 Connecting the system 8 Expl...

Страница 3: ...3 1 Getting Started 2 Safety instruction...

Страница 4: ...se the product in the manner indicated by may depending on circumstances also have severe consequences All of the symbols described above indicate important safety information Obey all safety informat...

Страница 5: ...5 3 Installation siting...

Страница 6: ...in Yaw Control Free yaw 360 degrees Direction Control Swing tail Over Wind Control Stall control 600rpm mode Start up Wind Speed 3m s 11KPH 6 7MPH Cut out Wind Speed 20m s 72KPH 45MPH Survival Wind S...

Страница 7: ...7 6 Assembling module 6 1 Verify the following upon purchase Tail Unit The body Unit and the tail is packed in the same box Optional parts Remote Monitor System...

Страница 8: ...8...

Страница 9: ...9...

Страница 10: ...10 7 Connecting the System 7 1 Before connecting...

Страница 11: ...11 7 5 Connection example...

Страница 12: ...12 7 6 Connecting the System...

Страница 13: ...ion Flashing green Generating power at con trolled rpm Wind speed range 12 20m s 43 72KPH 27 45MPH The rpm is limited to 1000 Normal Operation Flashing red Generating power at con trolled 600rpm Wind...

Страница 14: ...ank depends on its capacity in Ah the average consumption cur rent of the loads and the average power supplied by the turbine This average power depends on the average wind speed condition in MPH at y...

Страница 15: ...e of the wires at the end of the cable to reduce its diameter or use a proper spade or pin crimp terminal 9 4 Inverters This device is used to convert the DC power from the battery to the standard AC...

Страница 16: ...16...

Страница 17: ...ion When strong winds blow tree branches and other objects may make contact with and damage the wind turbine its support pole or its wiring Continued use of the wind turbine when it is damaged may cau...

Страница 18: ...be replaced Insufficient charging current to the battery bank when the rotor is run ning Consistent air turbulence condition 1 Change the location and or increase the height of the tower mast Make su...

Страница 19: ...DPDT switch is not in The rotor remains stopped even with high wind speed conditions If the indicator light is off There is some mechanical problem rotor shaft bearings hub internal stator and rotor...

Страница 20: ...system 28 6V Battery bank capacity in Ah lower than the recommended absolute minimum of 420Ah The battery bank voltage increases easily and fast forcing the unit to activate the controlled rpm mode an...

Страница 21: ...ber Installation Date Installation Location Other Requirements Send at least three photos of the working wind turbine Warranty Service Card Client Name Model Number Installation Date Phone Number Appl...

Отзывы:

Похожие инструкции для AWS2000