the platform. Wait 3-4 seconds. The LCD display 

reads “PASS”, then displays the cal weight again.

5. Remove the weight and press [ON/OFF] to turn off 

the scale. Finished! Repeat if needed.

Check with your scale supplier for calibration weights.

IV. TROUBLESHOOTING

The primary reasons for inaccuracy or malfunction 

are low batteries, incorrect calibration, overload or 

operating on an unstable surface. Please keep this in 

mind and maintain and operate your scale properly. 

This scale is a precise instrument and must be 

handled with the utmost care and caution.

[Display]

  Elimination of errors

Nothing, Battery-Symbol, [lo] or [88888] 

 

Change the batteries.

[OUE2]  

  Recalibrate the scale as shown above.

[EEEEE] 

  You are overloading the scale. Remove the  

 

excessive load immediately!

[LLLLL] 

  The delicate weighing load cells have  

 

been damaged by misusing the scale  

 

(i.e. it was shocked, dropped or    

 

overloaded). You can try recalibrating the  

 

scale. If the load cell has not been  

 

damaged too much it will work  

 

 

again after recalibration.

[UNST]  

  Use the scale in a more stable position

Содержание AMW-Card400

Страница 1: ...American Weigh Scales Inc AMW Card400 AMW Card50 User Manual Card Scale D i g i t a l P o c k e t S c a l e ...

Страница 2: ...r at least one hour before use Give your scale sufficient warm up time Usually 30 60 seconds before calibration to give the internal components a chance to stabilize Keep your scale in a clean environment Dust dirt moisture vibration air currents and a close distance to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently ...

Страница 3: ...ght item III CALIBRATION Calibration is NOT required before first use Only calibrate if scale is not weighing properly Make sure you use the correct calibration weight for your scale or the calibration will not be accurate Card 400 200g calibration weight Card 50 50g calibration weight 1 Turn OFF the scale 2 Press ON OFF shortly Then immediately press and hold MODE until CAL is displayed Release t...

Страница 4: ...maintain and operate your scale properly This scale is a precise instrument and must be handled with the utmost care and caution Display Elimination of errors Nothing Battery Symbol lo or 88888 Change the batteries OUE2 Recalibrate the scale as shown above EEEEE You are overloading the scale Remove the excessive load immediately LLLLL The delicate weighing load cells have been damaged by misusing ...

Страница 5: ...ct 771 5gn Resolution 0 1g 0 01oz 0 01ozt 0 1dwt 0 01g 0 001oz 0 05ct 0 1gn Display 4 Digit Backlit LCD Calibration Weight not Included 200g 50g Platform Dimensions inches 2 5 x 3 Scale Dimensions inches 5 x 3 x 0 75 Power 2 x CR2032 Batteries included Gross Weight 0 28 lb Specifications ...

Отзывы: