background image

 7

INSTALLATION 

           

Installing the Range Hood

•  Determind how high you want to install your range 

hood above the stove top and draw a horizontal line 
with a pencil. 24" to 30" Height is recommended.

The following steps requires 2 or more people:

•  Remove the 

Baffle Filters

 to reduce the weight for 

installation.

•  Raise the

 Hood Body

 so that the bottom of the 

Body

 is leveled with the pencil line.

•  Mark the locations of the 

Hanging Holes

 on the 

wall with a pencil.

•  Put down the 

Hood Body

, align the screws with the 

marked locations and drive them into the wall, with 
a small portion of the screws remain outside of the 
wall.

•  Raise the 

Hood Body

 and hang it onto the screws 

on the wall.

•  Align and install the 

Top Bar

 close to the 

Ceiling

Make sure that the 

Top Bar 

is inline with the bottom 

half of the 

Chimney

 and its height isn't exceeding 

the maximum height of the 

Chimney

.

•  Connect the Duct to the Adaptor on the Hood Body 

and seal the connection with foil tape or duct tape.

•  Install the 

bottom half of the Chimney

 to the 

Hood 

Body

.

•  Insert the top half of the 

Chimney

 into the bottom 

half.

•  Extend the top half of the 

Chimney

 till it reaches the 

Top Bar

•  Install the top half of the 

Chimney

 to the 

Top Bar

 

with 

2 screws

 each on the 

left and right sides of 

the Chimney

.

Top Bar

Hanging Holes

Hang the Hood onto the Screws

Содержание GU10

Страница 1: ...2021B Test Run Before Installation Important Make sure to manually spin the fan wheel to check if it s running without any obstacles before the test run If the fan wheel is unbalanced or in contact with the casing refer to Page 11 for how to re seat the fan wheel ...

Страница 2: ...ble both portions of the hood using the supplied Corner Brackets and Screws from inside the hood body before installing the range hood See diagram below Please read all instructions carefully before proceeding further to prevent the risk of fire electric shock personal injury or damage to the range hood This manual provides a general insight on the installation and may not include solutions for al...

Страница 3: ...irement 6 Installation 7 Installing the Range Hood 7 Connecting the Vent System 8 Electrical Connection 8 Installing the Baffle Filters 8 Completing the Installation 8 Range Hood Use 9 Range Hood Control Panel 9 Range Hood Care 10 Clean the Exterior Surfaces 10 Clean or Replace the Baffle Filters 10 Replace the LED Lamps 10 Range Hood Troubleshooting 11 Warranty 13 ...

Страница 4: ...walls ceiliings attics crawl spaces or garages TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilatin...

Страница 5: ...te for the venting system for a better performance Use silver tap or duct tap to seal all joints in the venting system Use caulking silicone to seal exterior wall or roof opening around the cap Always keep the duct clean to ensure proper airflow DO NOT End the venting system in an enclosed area indoors Use plastic vent Use no more than three 90 elbows Install 2 elbows together Install the range ho...

Страница 6: ...reach and hense reduce its performance and efficiency Minimum Duct Size Round 6 minimum Rectangular 3 1 4 x 10 minimum IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To ensure that the electrical installation is in compliance with applicable codes and standards Electrical Requirements A 120V 60Hz AC only 15A fuse...

Страница 7: ... a small portion of the screws remain outside of the wall Raise the Hood Body and hang it onto the screws on the wall Align and install the Top Bar close to the Ceiling Make sure that the Top Bar is inline with the bottom half of the Chimney and its height isn t exceeding the maximum height of the Chimney Connect the Duct to the Adaptor on the Hood Body and seal the connection with foil tape or du...

Страница 8: ...L listed wire connectors Store the excess wires in the wiring box Reconnect the power Installing the Oil Collector Locate the recess support in the bottom near the rear of the range hood Fit the oil tunnel container into the recess support Installing the Baffle Filters Peel off the protective cover from the baffle filters if there s any Level the baffle filter horizontally with the correct front a...

Страница 9: ...ting the minutes touch the Delayed Auto Shut Off button to confirm all settings Touch the Light button to check and validate the time When the Delayed Auto Shut Off fuction is activated while the blower is running a countdown timer will show up in the LCD Display Light Touch the Light button once and the lamps will turn on Touch the Light button again and the lamps will turn off The Light button o...

Страница 10: ...le and remove the filter by pulling it down Wash the filters in the dishwasher or soak it into hot or warm water with dish detergent for half an hour then wipe the filter clean Repeat these steps until there s no oil residue remains Let the filters dry thoroughly Make sure the spring release handle is toward the front align and insert the filter Pull the spring release handle and push the filter i...

Страница 11: ...ons with smaller sizes between the hood and the Roof Wall Cap Range hood WILL NOT function efficiently with insufficient duct size For example 7 duct over 6 top vent and not sealed properly Check if the duct is clogged or the damper half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap might also cause restriction to the air flow The lights work but t...

Страница 12: ...the hood to the main power Run the hood in different speeds to check if the issue is fixed Follow these instructions to replace the fan wheel with a new one Remove all 4 screws holding the blower casing Figure 4 Take out the blower casing Rotate the fan wheel so that the blade with two small cuts is facing you Figure 3 Use a long screwdriver to slightly loosen the fixing screw Remove all 3 screws ...

Страница 13: ...as not installed properly Damage of product caused by incorrect electrical wiring commercial or industrial use or use of any cleaning products not recommended in this manual Damage of product due to product misuse abuse improper installation unauthorized repair or maintenance Awoco is not responsible for any labor costs associated with removing servicing installing or determining the source of pro...

Страница 14: ...ason for refund You will be responsible for all returned shipping costs We can help arrange for a pickup if requested Product Support and Additional Information If you need assistance using your product or you would like to start the warranty service Contact us at 1 888 412 3428 between 11 AM and 5 PM Monday Friday Pacific Time Or Contact us at www awoco com pages contact us WARRANTY ...

Страница 15: ...Website www awoco com Customer Support 1 888 412 3428 ...

Отзывы: