AWID Sentinel-Sense ADB-512 Скачать руководство пользователя страница 3

ADB-512

This  transmitter  must  not  be
antenna or transmitter.

Radiation Exposure Statement

This equipment complies with
environment.  This  equipment
23 cm between the radiator & 

This  module  is  intended  for 
Manual  v01  guidance,  the  fol
this certified module:

KDB 996369 D03 OEM M

2.2 List of applicable FCC 

This module has been 

2.3 Summarize the specific 

The  module  is  tested 
other  usage  conditions 
used in a portable cond
II permissive change ap

2.4 Limited module proced

Not applicable.

2.5 Trace antenna designs

Not applicable.

2.6 RF exposure considera

This equipment complie
an uncontrolled environ
with  a  minimum  distan
module is installed in a
confirm compliance wit

2.7 Antennas

The following antennas ha
type with equal or lower ga
installed such that 23 cm ca

Manufacturer/

Brand

Model

Antenna

Type

Antenna

connector

Max Gain (dBi) Impedance (Ω)

AWD

ANT-915CPS

Patch

TNC, RP

5.8

50

AWD

ANT-915-CP-R

Patch

SMA, RP

5.5

50

AWD

ANT-2012

Patch

SMA, RP

5.4

50

AWD

ANT-915-CC-05

Patch

TNC, RP

4.7

50

- 3 -

7/

e  co-located  or  operating  in  conjunction 

t:

h FCC radiation exposure limits set forth for 

t  should  be installed  and  operated  with  min

& your body.

OEM  integrators  only.  Per  FCC  KDB  996369

llowing  conditions  must  be  strictly  followed

Manual v01 rule sections:

CC rules

 tested for compliance to FCC Part 15

ic operational use conditions

for  standalone  mobile  RF  exposure  use  co

s  such  as  co-location  with  other  transmitte
dition will need a separate reassessment th

pplication or new certification.

dures

s

ations

ies with FCC mobile radiation exposure limit

nment. This equipment should be installed 

nce  of  23 cm  between  the  radiator  &  you

a portable host, a separate SAR evaluation 

th relevant FCC portable RF exposure rules.

ave been certified for use with this module; antenn

ain may also be used with this module. The anten

can be maintained between the antenna and users.

Manufacturer/

Brand

Model

Antenna

Type

Antenna

connector

Max Gain (dBi) Impedance (Ω)

AWD

ANT-915CPS

Patch

TNC, RP

5.8

50

AWD

ANT-915-CP-R

Patch

SMA, RP

5.5

50

AWD

ANT-2012

Patch

SMA, RP

5.4

50

AWD

ANT-915-CC-05

Patch

TNC, RP

4.7

50

7/19/2021

with  any  other

 an uncontrolled

inimum  distance

996369  D03  OEM

ed  when  using

condition.  Any

er(s)  or  being

hrough a class

ts set forth for

and operated

ur  body.  If  the

 is required to

s.

nas of the same

nna must be

rs.

Manufacturer/

Brand

Model

Antenna

Type

Antenna

connector

Max Gain (dBi) Impedance (Ω)

AWD

ANT-915CPS

Patch

TNC, RP

5.8

50

AWD

ANT-915-CP-R

Patch

SMA, RP

5.5

50

AWD

ANT-2012

Patch

SMA, RP

5.4

50

AWD

ANT-915-CC-05

Patch

TNC, RP

4.7

50

Содержание Sentinel-Sense ADB-512

Страница 1: ...ADB 512 SENTINEL Installation 1 7 NEL SENSE ADB 512 Operation Manual 0415 7 19 2021 527...

Страница 2: ...ed and is believed t or inaccuracies AWID reserves the right to ma ment is not covered by any warranty either exp ctions or additions to the contents of this docum address in USA roperty of their resp...

Страница 3: ...KDB 996369 llowing conditions must be strictly followed Manual v01 rule sections CC rules tested for compliance to FCC Part 15 ic operational use conditions for standalone mobile RF exposure use co s...

Страница 4: ...h other tran re a separate class II permissive change re art 15 Subpart B disclaimer le is tested as a subsystem and its certifica 15 Subpart B unintentional radiator rule host The final host will sti...

Страница 5: ...interference that rme aux CNR d ISED applicables aux appa ation est autoris e aux deux conditions suiva de brouillage pr judiciable et 2 ce disposi y compris un brouillage susceptible de prov ent with...

Страница 6: ...ssible maximal Les types d antenne non inclus dans cette liste et dont le gain est sup rieur au gain maximal indiqu pour tout type figurant sur la liste sont strictement interdits pour l exploitation...

Страница 7: ...ui Le manuel de l utilisateur final requises et avertissements co 7 7 nd User o be aware not to provide information to remove this RF module in the user s man module nclude all required regulatory inf...

Страница 8: ...AM 5 1 System Operation 5 1 1 Running a Custo 5 2 Users Note 6 REFERENCE NOTE RE NOTE FAILURE TO FOLLOW POOR PERFORMANCE OR READER THUS VOIDS THE 8 7 Table of Contents PLIANCE Table gnment stance RATI...

Страница 9: ...ID Engineering 0 2 AWID Engineering 0 3 AWID Engineering 9 7 REVISION HISTORY Date Sections Affected Rema g 6 2021 Initial version g 7 2021 p 5 Editorial IC Complia g 7 2021 p 2 p 5 Updated FCC IC C 7...

Страница 10: ...ams are applicati 10 7 512 is a 4 port long range Radio Frequency 3 V TTL logical interface that works with mo dule comes with a unique combination of lo nsumption Its primary applications are asse ge...

Страница 11: ...kHz typical Pseudo random 30 C to 65 C 22 F to 149 F 3 3V TTL Serial 10 pin ZIF 2 11 x4 25 x0 35 QUENCY TABLE 927 40 MHz Minimum number of frequency cha MHz CH 902 928 MHz CH 902 928 MHz MHz 50 912 60...

Страница 12: ...hin three 3 inches of the t 12 7 IN ASSIGNMENT Pin Function 6 GND 7 Unit Enable 8 SCIR 9 SCIT 10 GND ally pulled high User may leave this pin unc d READ DISTANCE g types For certain readers and tags u...

Страница 13: ...longe source 13 7 OPERATION GUIDELINES R reader in this section refers to an RFID dev gh performance circular polarized antenna i case The module should be installed on a h be an aluminum plate of si...

Страница 14: ...e demo software Select COM port 1 commands 14 7 PROCEDURE on and operation information for ADB 512 read ow are present before starting the installatio 512 FOR INSTALLATION connectors and pin out assig...

Страница 15: ...ication Protoco MPR Command Demo II Quick 15 7 GRAMMING AND SYSTEM OPERATION NO ATION om Software Application or the AWID Demo t used it is expected user will launch a Cust he MPR Communication Protoc...

Отзывы: